Previous Article | Next Article ![]()
Journal of Clinical Microbiology, November 2002, p. 4121-4125, Vol. 40, No. 11
0095-1137/02/$04.00+0 DOI: 10.1128/JCM.40.11.4121-4125.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
Antimicrobial Agents Research Group, Division of Infection and Immunity, University of Birmingham, Birmingham B15 2TT,1 Department of Bacterial Diseases, Veterinary Laboratories Agency, New Haw, Surrey KT15 3NB, United Kingdom2
Received 24 April 2002/ Returned for modification 13 July 2002/ Accepted 20 August 2002
|
|
|---|
|
|
|---|
Resistance to quinolones in Salmonella enterica is chromosomal in origin and is typically caused by mutations in gyrA that result in amino acid substitutions in the GyrA subunit of DNA gyrase (9). A mutation in the gene encoding the A subunit of topoisomerase IV (parC) has been reported only recently [H. Hansen, W. Rabsch, and P. Heisig, J. Antimicrob. Chemother. 47(Suppl. 1):37, abstr. P80, 2001]. Other mechanisms, such as a decrease in drug permeability and active efflux mechanisms, can also contribute to quinolone resistance (9). Point mutations in gyrA associated with resistance to nalidixic acid and decreased susceptibility to ciprofloxacin are found within the QRDR that includes amino acids 67 to 122 (9).
Here we show that denaturing high-performance liquid chromatography is a rapid method for the detection of mutations within the gyrA gene from different serovars of S. enterica.
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Comparison of DHPLC, LightCycler, and SSCP methods for mutation detection in gyrA QRDR from Salmonella
|
Typical reaction mixtures (50 µl) contained PCR Master Mix (1.5 mM MgCl2) (ABgene), 0.5 µg of DNA, and 250 nM (each) primer. DNA was amplified using a Techne thermal cycler as follows: (i) an initial denaturing step of 10 min at 95°C; (ii) 30 cycles of PCR, with 1 cycle consisting of 1 min at 95°C, 1 min at 52°C, and 30 s at 72°C; and (iii) a final extension step of 10 min at 72°C. PCR products were checked for purity by 1.2% agarose gel electrophoresis in 1x Tris-borate-EDTA (TBE) buffer containing 10 µg of ethidium bromide per liter. Products were then quantified by Gene Tools software (Syngene).
DHPLC analysis.
DHPLC was performed with the Wave DNA fragment analysis system (Transgenomic Inc.) which employs a combination of temperature-dependent denaturation of DNA and ion pair chromatography. Briefly, DNA specifically amplified from the test strain is mixed with that amplified from the wild-type strain. The amplimers are denatured simultaneously in the same reaction mixture and then allowed to slowly reanneal. Thus, four species of duplex DNA can form. Heteroduplexes will result in double-stranded DNA containing a mismatch bubble at the point mutation site. Under the nondenaturing conditions (
51°C) used to separate DNA fragments, all four duplexes will have the same retention time during ion pair chromatography. As the temperature increases to 54 to 63°C (dependent on DNA sequence), the heteroduplex DNA fragments start to denature in the region on either side of the mismatched bases and begin to emerge ahead of the still intact homoduplexes. It is this combination of ion exchange and partial denaturation that forms the basis of DHPLC. Temperature-dependent resolution of homo- and heteroduplexes occurs and can range from full separation of all four duplex species to a single peak with a shift in retention time dependent upon analysis temperature (Transgenomic application note 101, Transgenomic, Inc.). These changes in elution profile are indicative of mutations in the DNA. Subtle differences in elution profile were confirmed by overlay of the profiles in question using WAVEMAKER software. This was particularly important for the recognition of multiple mutations.
PCR products (5 µg) were mixed with an equal amount of DNA amplified from a wild-type standard. DNA mixtures were hybridized to form heteroduplexes by heating to 95°C (4 min) and then cooled gradually by ramping the temperature down to 35°C in 1°C/min steps. The WAVEMAKER utility software was used to determine the correct partial denaturation temperature for mutation scanning based on the sequence of the wild-type DNA from S. enterica serovar Typhimurium NCTC 74.
Duplex products were analyzed using the Wave Nucleic Acid fragment analysis system. Duplex DNA (5 µg) was loaded on the DNASepCartridge (Transgenomics) in 54% eluent A-46% eluent B. The gradient for separation was a 4-min linear gradient from 51% eluent B to 59% eluent B. The flow rate was 0.9 ml min-1. Eluent A contained 0.1 M triethylammonium acetate (TEAA), and eluent B contained 0.1 M TEAA in 25% (vol/vol) acetonitrile. The column was subsequently washed in 100% eluent B for 30 s and then reequilibrated with 54% eluent A-46% eluent B. DNA fragment elution profiles were captured online and visually displayed using Transgenomic WAVEMAKER software.
DHPLC analysis was initially performed at 61°C (the predicted average melting temperature over the whole 251-bp gyrA fragment was 62°C) and then at 63°C to optimize mutation detection at the 3' region.
Twelve consecutive analyses of S. enterica serovar Typhimurium NCTC 74 wild-type DNA were performed to test the reproducibility of retention times (data not shown). The retention time for DNA from this strain at 61°C was between 5.603 and 5.683 min. Profiles with identical shapes by eye but with a shift in retention time greater than this range were assumed to indicate the presence of different heteroduplexes and DNA sequenced.
Detection of gyrA mutations using LightCycler GAMA. The region of DNA encompassing the nucleotides between codons 71 and 102 of gyrA was amplified, fluorescently labeled with Sybr green 1 (SG1), and hybridized to the fluorescence-labeled (cyanine 5 [Cy5]), mutation-specific oligonucleotide probe as described previously (12). Hybridization of the probe to the target DNA resulted in an increase in Cy5 fluorescence due to fluorescence resonance energy transfer between Sybr green 1 and Cy5. When the specific mutation was not present, the mismatches between the probe and the target gave a decrease in fluorescence at a lower melting temperature than for a hybrid where there were no mismatches. gyrA hybridization mutation assay (GAMA) reactions were performed in a LightCycler instrument (Roche Diagnostics Ltd.). The detection of mutations was achieved by melting analysis of the oligonucleotide probe and the PCR amplicon immediately after the amplification protocol using probes specific for the substitutions Ser83-Phe, Ser83-Tyr, Asp87-Gly, Asp87-Asn, and Asp87-Tyr (4). Probes were tested in order of the prevalence of the mutation in S. enterica.
SSCP. SSCP analysis of the PCR products obtained using primers stgyrA1 and stgyrA2 was used as previously described previously (3). Denatured DNA (5 µg) was loaded on to a CleanGel 48S polyacrylamide gel for electrophoresis. DNA was stained using PlusOne silver staining kit (AP Biotech).
DNA sequencing and nucleotide sequence analysis. PCR products required for sequencing were cleaned using Qiaquick PCR purification Kits (Qiagen). PCR product (5 ng) was used as template for TaqCycle Sequencing using ABI Prism Big Dye Terminator version 3.0 cycle sequencing kits (Applied Biosystems). Cycle sequencing products were subsequently analyzed on ABI PRISM 3700 DNA analyzer (Functional Genomics Laboratory, University of Birmingham). The DNA sequences of the QRDR of gyrA from nalidixic acid- and ciprofloxacin-sensitive S. enterica serovars Seftenberg, Fischerkietz, Newport, Virchow, and Saintpaul were determined to confirm their identity to that of S. enterica serovar Typhimurium NCTC 74.
|
|
|---|
Mutation detection by DHPLC analysis. The QRDR amplified from gyrA from nalidixic acid- and ciprofloxacin-sensitive strains of Salmonella serovars Senftenberg, Fischerkietz, Newport, Virchow, and Saintpaul were sequenced and shown to be identical to the equivalent region of gyrA in S. enterica serovar Typhimurium wild-type strain NCTC 74. The amplimer from the control strain NCTC 74 was mixed with each test amplimer for mutation detection analysis by DHPLC. DHPLC analyses were done at both 61 and 63°C to optimize mutation detection over the whole region of the DNA. Any change from the single-peak profile characteristic of wild-type NCTC 74 (Fig. 1a) indicated formation of heteroduplexes and therefore at least one mutation within the test DNA fragment.
![]() View larger version (10K): [in a new window] |
FIG. 1. DHPLC analyses of S. enterica strains at 61 and 63°C. The DHPLC profiles of S. enterica strains (mutations shown in parentheses) are shown in panels a to k as follows: a, NCTC 74 (wild type); b, L378 and L575 (Ser83-Phe); c, L400 (Asp72-Gly, Ser83-Phe, and Ala119-Ser); d, L522 (Ser83-Phe and Glu139-Ala); e, L471, L607 (Ser83-Tyr), and L537 (Ser83-Tyr and Ala131-Ala); f, L21 (Asp87-Gly); g, L24 (Asp87-Gly and Asp144-Asp); h, L469 (Asp87-Gly and Ala131-Gly); i, L90 (Asp87-Tyr); j, L574 (Asp82-Asn); k, L4 (Ala119-Glu).
|
Seven novel mutations were identified at five different loci not previously described in quinolone-resistant salmonella. These novel mutations were located within the QRDR at codons Asp72, Asp82, and Ala119. Novel mutations outside the QRDR but within the region of DNA amplified were at codons Ala131, Glu139, and Asp144.
The DHPLC profiles from each representative strain are shown in Fig. 1, and the mutations were confirmed by DNA sequencing in Table 1. Strains L378, L575, L400, and L522 contained changes in codon 83 resulting in a Ser
Phe substitution. Three different profiles were seen for these strains, indicating the presence of different heteroduplexes formed with NCTC 74 DNA. L378 and L575 share the identical profiles (confirmed by overlay of profiles) at both 61 and 63°C that proved characteristic of a Ser83-Phe substitution (Fig. 1b). L400 (Fig. 1c) and L522 (Fig. 1d) share the same type of profile at 61°C that is different to that of a single Ser83-Phe substitution. This was also true at 63°C, but when the profiles of L400 and L522 were overlaid using WAVEMAKER software, the heteroduplexes from L522 eluted earlier by 0.1 min, indicating they were different from L400. DNA sequencing confirmed that L400 and L522 contained multiple mutations at different loci (Table 1). Strains L471, L607, and L537 all shared the same profile (Fig. 1e) and contained mutations at codon Ser83 encoding a substitution to a tyrosine residue. Three peaks were seen at 63°C compared to two at 61°C. The additional mutation in L537 at Ala131 could not be resolved at these temperatures, presumably because the Ala131 mutation was towards the end of the test DNA fragment or a different analysis temperature is required for optimal mutation detection at this point. The Ser83-Phe profile (Fig. 1b) was quite different from the Ser83-Tyr profile (Fig. 1e).
L21 contains an Asp
Gly substitution at codon 87. It could not be differentiated from the wild type at 61°C but resolved into two peaks at 63°C (Fig. 1f) which is the optimum predicted melting temperature for this region. Strain L24 contains an additional silent substitution at Asp144-Asp (Fig. 1g), the L24 profile was different again from the single Asp87-Asn mutation in L21. L90 (Fig. 1i) and L469 (Fig. 1h) both contain a substitution at codon 87, but L469 has a further substitution at Ala131-Gly and consequently, the profile is different to that of L90. L4, which contains a single substitution at codon 119 nearer the 3' region of the DNA fragment, was better resolved at 63°C than at 61°C (Fig. 1k). L574 (Fig. 1j) contains a novel substitution at Asp82-Asn that is resolved at both 61 and 63°C.
Mutation detection by LightCycler GAMA analysis. All strains were tested for gyrA mutations between codons 82 and 88 by LightCycler GAMA using probes for the commonly found mutations Ser83-Phe, Ser83-Tyr, Asp87-Asn, Asp87-Gly, and Asp87-Tyr. Four types of mutation were found with these specific probes. A substitution at Asp87 in strain L90 was suggested by its melting curve but could not be confirmed using the three Asp87 probes. The Asp87-Tyr probe used recognized the TAT codon for tyrosine. DNA sequencing confirmed the mutation to be the TAC codon for the tyrosine substitution (Table 1). LightCycler GAMA analysis therefore requires several analyses using probes for each degenerate codon to confirm less-frequent mutations.
Mutation detection by SSCP analysis. The DNA amplified from all 14 strains, including the wild type, were analyzed for SSCP. Seven different patterns were detected by SSCP (Fig. 2). NCTC 74 shows wild-type pattern I. Patterns II, III, V, VI, and VII are characteristic of Ser83-Phe, Ser83-Tyr, Asp87-Gly, Asp87-Tyr, and Ala119-Glu substitutions, respectively. Pattern IV indicated a novel mutation that was confirmed as Asp82-Asn by DNA sequencing (Table 1).
|
View larger version (16K): [in a new window] |
FIG. 2. SSCP analysis of S. enterica strains. Lane 1, NCTC 74 (wild type); lane 2, L400 (pattern II); lane 3, L575 (pattern II); lane 4, L522 (pattern II); lane 5, L378 (pattern II); lane 6, L471 (pattern III); lane 7, L607 (pattern III); lane 8, L537 (pattern III); lane 9, L574 (pattern IV); lane 10, L21 (pattern V); lane 11, L24 (pattern V); lane 12, L469 (pattern V); lane 13, L90 (pattern VI); lane 14, L4 (pattern VII).
|
|
|
|---|
MAMA-PCR has also been used as a rapid method for detecting specific mutations within a short (21-bp) region of Campylobacter jejuni (13); however, speed is compromised by the need for analysis using combinations of several different probes. As with the GAMA method, this technique is limited to detecting known sequence variants.
GAMA requires individual oligonucleotide probes directed against the specific mutation including degenerate codons. Strains containing DNA that is homologous to the probes can be distinguished from those containing different mutations by their probe target melting temperatures. Probes are employed sequentially in order of mutation prevalence (Ser83-Phe is the first choice for salmonella) (7). LightCycler GAMA cannot confirm novel mutations because it is dependent upon specific probes but can suggest probe-DNA mismatches by a change in the melting curve profile. This technique frequently requires multiple oligonucleotide assays on each sample to determine their genotype. DNA samples that are mismatched to the probes must be sequenced. DHPLC requires one assay for each sample, and mutations are indicated simply by a shift in retention time or the characteristic separation of homoduplex and heteroduplex peaks.
The PCR product size is one of the critical factors in resolving denatured single-strand DNA, affecting the sensitivity and specificity of the SSCP technique (2). Pattern shifts associated with mutations close to the end regions of the DNA are also difficult to visualize by SSCP. The mutation at Glu139 in strain L522 was not seen as a conformational change by SSCP but was recognized as a shift in retention time and change in profile by DHPLC. The DHPLC WAVEMAKER utility software was able to predict melting temperatures throughout the length of DNA being analyzed, allowing optimization of mutation detection in specific regions of the amplimer. Mutations in several regions of the DNA were detected from one test sample. Further refinement of the run conditions may yield more dramatic shifts in elution profiles and detect mutations such as Ala131 in strain L469.
Although GAMA and SSCP detected the most common mutations described to date, the prevalence of previously undescribed mutations was not highlighted. This DHPLC method has extended our library of mutations within the QRDR of gyrA in quinolone-resistant S. enterica. DNA sequencing remains the "gold standard" for identifying mutations within the QRDR of gyrA (and other antibiotic resistance-conferring genes) and has recently become faster and more cost-effective. However, screening all topoisomerase genes (gyrA, gyrB, parC, and parE) from several hundred clinical isolates is still very costly. DHPLC provides a high-throughput method for detecting both previously documented mutations, multiple mutations, and novel mutations at the same time. The initial cost of the Transgenomic Wave DHPLC is offset by the accurate and high throughput of gyrA analysis that requires less operator time than the established PCR-based methods of SSCP and LightCycler GAMA. As a library of mutation standards is compiled, sequencing will be limited to the novel mutations. Our current work uses DHPLC to identify mutations in gyrB, parC, and parE, so that any relationship between MIC and specific mutations can be identified. Furthermore, large numbers of isolates will allow the prevalence of mutations in each gene to be determined.
We thank Anthony Jones, The Functional Genomics Laboratory, University of Birmingham, for DNA sequencing and all at Transgenomic, Crewe, United Kingdom for technical support.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»