Rapid Detection of Herpes Simplex Virus DNA in Genital Ulcers by Real-Time PCR Using SYBR Green I Dye as the Detection Signal
Carmen Aldea, Carmen P. Alvarez, Lola Folgueira, Rafael Delgado, and Joaquín R. Otero*
Servicio de Microbiología, Hospital 12 de Octubre, Madrid, Spain
Received 8 November 2001/
Accepted 4 December 2001

ABSTRACT
We have evaluated a real-time PCR procedure based on the LightCycler
technology for rapid detection of herpes simplex virus (HSV)
in genital lesions. Two sets of primers, corresponding to the
thymidine kinase and DNA polymerase regions, were used for the
amplification reactions in separate capillaries containing the
SYBR Green I dye as detection signal. In 28 of 118 samples (24%),
HSV was isolated by conventional cell culture. All cell culture-positive
samples were also positive by real-time PCR. Six additional
cell culture-negative samples were positive by PCR with both
sets of primers. Total processing time was less than 3 h. Real-time
PCR using SYBR Green I as detection signal is a sensitive procedure
for the rapid diagnosis of HSV in genital lesions.

TEXT
Herpes simplex virus (HSV) is frequently detected in mucocutaneous
lesions in the clinical virology laboratory (
2,
13). Conventional
cell culture still remains the diagnostic method of choice,
although enzyme-linked immunosorbent assay and immunofluorescence
techniques are available (
3). Nucleic acid technology based
on PCR has shown an interesting role in detection of HSV DNA
(
8,
10), and several protocols, adapted to clinical laboratories,
have been reported (
6,
14). However, conventional PCR techniques
have been so far relatively cumbersome, difficult to interpret,
and prone to contamination. Very recently, real-time PCR has
started to demonstrate its potential utility in the field of
clinical virology and, specifically, in the detection of herpesvirus
DNA (
1,
2,
9,
11,
12). The main features making this new technology
so attractively suitable for these applications, in comparison
with conventional PCR, are rapidness, possibility of accurate
quantification and, very important, reduction of likelihood
of contamination, since no postamplification analysis of the
tubes is required. Nevertheless, the value of this technology
for specific applications and the development of protocols to
be included in clinical laboratory routines remain to be established
through well-controlled clinical studies.
We have used a real-time PCR strategy, based on the Light Cycler technology, to detect HSV DNA in genital lesions from patients attending the sexually transmitted disease clinics of our institution, and the results were compared to those obtained by conventional cell culture. Swabs, taken from the surfaces of genital lesions and sent to the virology laboratory in 2 ml of viral transport medium (ViralPack; Biomedics S.L., Madrid, Spain), were inoculated to monolayers of A-549 and MRC-5 cells in tubes. These tubes were inoculated with 0.2 ml, incubated at 37°C in stationary phase, and scored daily for cytopathic effect (CPE) for 7 days or until CPE developed. When a characteristic HSV CPE was observed, a passage was done to two homologous monolayers in shell vials. These shell vials were incubated 24 h at 37°C and stained with specific fluorescent reagents to HSV type 1 (HSV-1) and HSV-2 (MicroTrak HSV 1-2 culture identification/typing test; Dade-Behring, Marburg, Germany). For the real-time PCR technique, 0.5 ml of the remaining transport medium was centrifuged at 12,000 x g for 10 min and the supernatant was vacuum aspirated so that the cellular pellet and 200 µl of transport media were left in the tube. DNA from this product was purified by a commercial procedure (High Pure Viral Nucleic Acid kit; Roche, Mannheim, Germany) and resuspended in water to a final volume of 50 µl. Two microliters of this purified DNA was used for real-time amplification in a final 10-µl reaction volume, using 1x Fast Start SYBR Green I Master Mix (Roche), MgCl2 (3 mM), and 0.5 µM concentrations of each primer. The capillary tubes were taken into the LightCycler instrument (Roche) and amplified as follows: 95°C for 7 min followed by 50 cycles of 95°C for 30 s, 62°C for 10 s, and 72°C for 12 s, followed by denaturation of amplification samples by slow increase of temperature (0.2°C/s) up to 99°C. Total processing time was less than 3 h. Samples were processed in duplicate with two different sets of primers, amplifying regions from thymidine kinase (Tk; 335 bp) and DNA polymerase (Pol; 215 bp), respectively (Tk-forward, GAC MAG CGC CCA GAT AAC AA; Tk-reverse, MCA GCA TRG CCA GGT CAA GC [GenBank accession no. M16321]; Pol-forward, GCT CGA GTG CGA AAA AAC GTT C; Pol-reverse, CGG GGC GCT CGG CTA AC [GenBank accession no. X03764 and X01712]; M being A or C and R being A or G) (2, 14). In order to use a quantitative control in the assay, these regions were amplified by conventional PCR from a control HSV-1 strain, and the fragments were cloned into pUC19. DH5
Escherichia coli was transformed with both constructions and, after expansion in culture, the plasmid was purified by double-banding CsCl ultracentrifugation and quantified. A panel of copies of the pUC19-Tk and Pol constructions, ranging from 1 to 106 copy numbers, was used for quantification (Fig. 1). Based on the fact that the 102-copy control of this panel was consistently detected by real-time PCR in repeated experiments, we decided to consider positive those samples showing specific signals for both sets of primers (melting temperature between 93 and 95°C) (Fig. 2) and a quantification higher than 10 DNA copies. Also for control purposes, two known samples and two cell cultures positive for varicella-zoster virus were processed, with negative results.
HSV was isolated in 28 of 118 samples (24%) processed by conventional
cell culture. Ten isolates (36%) were identified as HSV-1, and
18 (64%) were identified as HSV-2. All cell culture-positive
samples were positive by real-time PCR. Quantification of HSV
for these samples was in a range from 520 to 53
x 10
6 DNA copies
(geometric mean, 171,879 copies) for Tk primers and from 57
to 35
x 10
6 DNA copies (geometric mean, 38,795 copies) for the
Pol primer set. The global performance of the real-time PCR
on clinical samples is as follows: of 28 samples testing positive
with conventional cell culture, real-time PCR detected 28 samples
as positive and none as negative; of 90 samples testing negative
with conventional cell culture, real-time PCR detected 84 as
negative and 6 as positive. Taking conventional culture as the
"gold standard," sensitivity was 100%, whereas specificity was
93%. However, if we consider that in six culture-negative samples
the positivity of PCR was achieved with both sets of primers,
in independent reactions, and at copy numbers ranging from 360
to 7.8
x 10
6 with Tk primers (geometric mean, 70,498 DNA copies)
and from 15 to 3
x 10
6 with Pol primers (geometric mean, 16,328
DNA copies), we believe that these were false-negative culture
results rather than false-positive PCRs. Moreover, these real-time
PCR-positive cell culture-negative results were confirmed by
gel electrophoresis, showing amplification bands of the expected
molecular weights with both sets of primers.
Fluorescently labeled probes to detect the amplified products have been used in the majority of reports on real-time PCR for diagnostic purposes (5, 7). However, labeled probes are expensive and introduce an additional complexity to both the design and the parameters of the amplification reaction. Moreover, despite the use of specific probes, artifacts can occur, especially at amplification cycles beyond the 30th (1). No specific probes were used in our study, and the SYBR Green I dye provided the fluorescent signal (4). This approach is simpler, cheaper, and probably more sensitive, since many fluorescent labels, instead of just one molecule, are incorporated into the amplified fragment. On the other hand, the melting temperature of the amplified DNA (Fig. 2) allows a clear distinction of the specific products from artifacts, such as primer dimmer, that are also minimized by the hot-start step included in the procedure. To avoid unspecific signals and based in the quantification panel, we have established the positive cutoff at the 10-copy level, which represents a reasonable technical and clinical threshold. The only drawback of the system was the inability to differentiate accurately HSV-1 from HSV-2 in a single reaction, since the melting temperature of the fragments amplified in each type was measured within a too-narrow range. However, we think that HSV type identification is secondary to a rapid and consistent diagnosis and might well be performed, in a second step, on PCR-positive samples.
In conclusion, real-time PCR based in the capillary format of the LightCycler instrument and using the SYBR Green I fluorescent dye as the detection signal is a simple, rapid, sensitive, and specific tool for detection of HSV DNA from genital lesions.

ACKNOWLEDGMENTS
We acknowledge the technical assistance of C. Prieto, S. Maldonado,
and M. J. Babiano. C.P.A. is supported by Sociedad Española
de Enfermedades Infecciosas y Microbiología Clínica,
SEIMC.
This work was partially supported by grants from Fondo de Investigación Sanitaria FIS 99/514 and 01/1430 and FIPSE 3026/99 to R.D.

FOOTNOTES
* Corresponding author. Mailing address: Unidad de Virología, Servicio de Microbiología, Hospital 12 de Octubre, Madrid 28041, Spain. Phone: 34 91 3908428. Fax: 34 91 5652765. E-mail:
jrotero{at}hdoc.insalud.es.


REFERENCES
1
- Espy, M. J., T. K. Ross, R. Teo, K. A. Svien, A. D. Wold, J. R. Uhl, and T. F. Smith. 2000. Evaluation of LightCycler PCR for implementation of laboratory diagnosis of herpes simplex virus infections. J. Clin. Microbiol. 38:3116-3118.[Abstract/Free Full Text]
2
- Espy, M. J., J. R. Uhl, P. S. Mitchell, J. N. Thorvilson, K. A. Svien, A. D. Wold, and T. F. Smith. 2000. Diagnosis of herpes simplex virus infections in the clinical laboratory by LightCycler PCR. J. Clin. Microbiol. 38:795-799.[Abstract/Free Full Text]
3
- Johnston, S. L., and C. S. Siegel. 1990. Comparison of enzyme immunoassay, shell vial culture, and conventional cell culture for the rapid detection of herpes simplex virus. Diagn. Microbiol. Infect. Dis. 13:241-244.[CrossRef][Medline]
4
- Karlsen, F., H. B. Steen, and J. M. Nesland. 1995. SYBR green I DNA staining increases the detection sensitivity of viruses by polymerase chain reaction. J. Virol. Methods 55:153-156.[CrossRef][Medline]
5
- Lewin, S. R., M. Vesanen, L. Kostrikis, A. Hurley, M. Duran, L. Zhang, D. D. Ho, and M. Markowitz. 1999. Use of real-time PCR and molecular beacons to detect virus replication in human immunodeficiency virus type 1-infected individuals on prolonged effective antiretroviral therapy. J. Virol. 73:6099-6103.[Abstract/Free Full Text]
6
- Mitchell, P. S., M. J. Espy, T. F. Smith, D. R. Toal, P. N. Rys, E. F. Berbari, D. R. Osmon, and D. H. Persing. 1997. Laboratory diagnosis of central nervous system infections with herpes simplex virus by PCR performed with cerebrospinal fluid specimens. J. Clin. Microbiol. 35:2873-2877.[Abstract]
7
- Mullah, B., K. Livak, A. Andrus, and P. Kenney. 1998. Efficient synthesis of double dye-labeled oligodeoxyribonucleotide probes and their application in a real time PCR assay. Nucleic Acids. Res. 26:1026-1031.[Abstract/Free Full Text]
8
- Powell, K. F., N. E. Anderson, R. W. Frith, and M. C. Croxson. 1990. Non-invasive diagnosis of herpes simplex encephalitis. Lancet 335:357-358.[Medline]
9
- Read, S. J., J. L. Mitchell, and C. G. Fink. 2001. LightCycler Multiplex PCR for the laboratory diagnosis of common viral infections of the central nervous system. J. Clin. Microbiol. 39:3056-3059.[Abstract/Free Full Text]
10
- Rowley, A. H., R. J. Whitley, F. D. Lakeman, and S. M. Wolinsky. 1990. Rapid detection of herpes-simplex-virus DNA in cerebrospinal fluid of patients with herpes simplex encephalitis. Lancet 335:440-441.[CrossRef][Medline]
11
- Schalasta, G., A. Arents, M. Schmid, R. W. Braun, and G. Enders. 2000. Fast and type-specific analysis of herpes simplex virus types 1 and 2 by rapid PCR and fluorescence melting-curve-analysis. Infection 28:85-91.[CrossRef][Medline]
12
- Schalasta, G., M. Eggers, M. Schmid, and G. Enders. 2000. Analysis of human cytomegalovirus DNA in urines of newborns and infants by means of a new ultrarapid real-time PCR-system. J. Clin. Virol. 19:175-185.[CrossRef][Medline]
13
- Smith, T. F., A. D. Wold, M. J. Espy, and W. F. Marshall. 1993. New developments in the diagnosis of viral diseases. Infect. Dis. Clin. N. Am. 7:183-201.[Medline]
14
- Tang, Y. W., P. S. Mitchell, M. J. Espy, T. F. Smith, and D. H. Persing. 1999. Molecular diagnosis of herpes simplex virus infections in the central nervous system. J. Clin. Microbiol. 37:2127-2136.[Free Full Text]
Journal of Clinical Microbiology, March 2002, p. 1060-1062, Vol. 40, No. 3
0095-1137/02/$04.00+0 DOI: 10.1128/JCM.40.3.1060-1062.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Yu, K.-D., Di, G.-H., Yuan, W.-T., Fan, L., Wu, J., Hu, Z., Shen, Z.-Z., Zheng, Y., Huang, W., Shao, Z.-M.
(2009). Functional polymorphisms, altered gene expression and genetic association link NRH:quinone oxidoreductase 2 to breast cancer with wild-type p53. Hum Mol Genet
18: 2502-2517
[Abstract]
[Full Text]
-
Geretti, A M
(2006). Genital herpes. Sex. Transm. Infect.
82: iv31-iv34
[Full Text]
-
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R. III, Smith, T. F.
(2006). Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing. Clin. Microbiol. Rev.
19: 165-256
[Abstract]
[Full Text]
-
Geretti, A M, Brown, D W
(2005). National survey of diagnostic services for genital herpes. Sex. Transm. Infect.
81: 316-317
[Abstract]
[Full Text]
-
Namvar, L., Olofsson, S., Bergstrom, T., Lindh, M.
(2005). Detection and Typing of Herpes Simplex Virus (HSV) in Mucocutaneous Samples by TaqMan PCR Targeting a gB Segment Homologous for HSV Types 1 and 2. J. Clin. Microbiol.
43: 2058-2064
[Abstract]
[Full Text]
-
Issa, N. C., Espy, M. J., Uhl, J. R., Harmsen, W. S., Mandrekar, J. N., Gullerud, R. E., Davis, M. D., Smith, T. F.
(2005). Comparison of Specimen Processing and Nucleic Acid Extraction by the Swab Extraction Tube System versus the MagNA Pure LC System for Laboratory Diagnosis of Herpes Simplex Virus Infections by LightCycler PCR. J. Clin. Microbiol.
43: 1059-1063
[Abstract]
[Full Text]
-
Enomoto, Y., Yoshikawa, T., Ihira, M., Akimoto, S., Miyake, F., Usui, C., Suga, S., Suzuki, K., Kawana, T., Nishiyama, Y., Asano, Y.
(2005). Rapid Diagnosis of Herpes Simplex Virus Infection by a Loop-Mediated Isothermal Amplification Method. J. Clin. Microbiol.
43: 951-955
[Abstract]
[Full Text]
-
van Doornum, G. J. J., Guldemeester, J., Osterhaus, A. D. M. E., Niesters, H. G. M.
(2003). Diagnosing Herpesvirus Infections by Real-Time Amplification and Rapid Culture. J. Clin. Microbiol.
41: 576-580
[Abstract]
[Full Text]