This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van der Zee, A.
Right arrow Articles by Templeton, K. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van der Zee, A.
Right arrow Articles by Templeton, K. E.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, March 2002, p. 1126, Vol. 40, No. 3
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.3.1128.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.

LETTER TO THE EDITOR

Qiagen DNA Extraction Kits for Sample Preparation for Legionella PCR Are Not Suitable for Diagnostic Purposes


arrow
LETTER
 
Several reports describe the use of Qiagen columns as part of a Legionella PCR (1, 2). However, workers in two laboratories in The Netherlands have found that the Qiagen columns are contaminated with Legionella species.

Nucleic acid sample preparation kits are commercially available from many different suppliers. Some of the most commonly used are the silica-based gel membrane or glass fiber filter columns of Qiagen, which specifically bind DNA while contaminating RNA and proteins are removed. They are widely used to extract DNA from a variety of clinical specimens such as: sputum samples, bronchoalveolar lavage (BAL) samples, aspirates, biopsy specimens, and blood and tissue samples. Recovery of DNA from the columns is highly efficient, and PCR inhibitors are effectively reduced.

In the Tilburg laboratory, the Qiagen columns (QIAamp DNA mini kit; Qiagen, Hilden, Germany) have been used for the extraction of DNA from sputum samples or BAL samples, to be tested by the Legionella PCR/probe assay. Negative controls, consisting of water (guaranteed DNA and RNA free; Sigma), were processed after every four clinical samples. At one point, it was found that some of the negative controls were positive for Legionella species other than Legionella pneumophila. The occurrence of false positivity coincided with the use of a new batch of QIAamp columns. When water was processed in 20 columns, a Legionella-positive signal was seen after PCR in 4 of 20 columns but never in the unprocessed water (Fig. 1). All the individual components of the Qiagen kit were tested, showing that the source of the contamination was in the columns. The Qiagen distributor in the Netherlands provided the laboratory with 3 other batches of columns. A total 20 columns of each batch were tested. With one batch, all 20 columns tested were negative, but the other 2 batches were contaminated with Legionella DNA.



View larger version (81K):
[in this window]
[in a new window]
 
FIG. 1. Agarose gel containing the PCR products from DNA- and RNA-free water, processed by QIAmp DNA extraction (lanes 1 to 20), positive controls (lanes 21 to 23), and a negative control (lane 24). Lanes M contain marker DNA.

At the Leiden University Medical Center, a Legionella species-specific real-time PCR assay is being developed, and similar findings were obtained with the Qiagen columns while the specificity of the assay was being determined. Legionella species were extracted with Qiagen columns, with negative extraction controls included after every five samples. When a positive signal was seen in the extraction controls, all potential sources of contamination were investigated and the columns were found to be the source. Other extraction methods have now been employed to continue using the PCR.

The production of columns involves continuous flushing with water (Qiagen distributor [Westburg, Leusden, The Netherlands], personal communication), and during the process Legionella-containing amoeba, DNA, or bacterial cells present in the water may settle on the column material. Pretreatment of columns with DNAase did not eliminate the contamination. In collaboration with the manufacturer, many batches either pretreated with gamma irradiation or from different lots, have been tested. All batches were found to be contaminated; the level of Legionella contamination ranged from 10% to 70%. Our findings emphasize the importance of sufficient negative controls in PCR methods for detection and diagnosis of L. pneumophila and for species other than L. pneumophila, in order to detect the contamination. Although efficiently used for many applications, Qiagen columns at the present time are not suitable for laboratory diagnosis of Legionella infection.


arrow
REFERENCES
 
    1
  1. Cloud, J. L., K. C., Caroll, P. Pixton, M. Erali, and D. R. Hillyard. 2000. Detection of Legionella species in respiratory specimens using PCR with sequencing confirmation. J. Clin. Microbiol. 38:1709-1712.[Abstract/Free Full Text]
  2. 2
  3. Jonas, D., A. Rosenbaum, S. Weyrich, and S. Bhakdi. 1995. Enzyme-linked immunoassay for detection of PCR-amplified DNA of Legionellae in bronchoalveolar fluid. J. Clin. Microbiol. 33:1247-1252.[Abstract]
Anneke van der Zee*
Marcel Peeters
Caroline de Jong
Harold Verbakel

Laboratory of Molecular  Microbiology
St. Elisabeth Hospital
P. O. Box 747
5000 AS Tilburg
The Netherlands

Jantine W. Crielaard
Eric C.J. Claas
Kate E. Templeton

Leiden University Medical  Centre (LUMC)
Laboratory of Medical  Microbiology
2300 RC Lieden
The Netherlands

* Phone: 31 13 539 2676
Fax: 31 13 544 1264
E-mail: anzee{at}elisabeth.nl


Journal of Clinical Microbiology, March 2002, p. 1126, Vol. 40, No. 3
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.3.1128.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Diederen, B. M. W., Peeters, M. F., Metzgar, D. (2007). Are Oropharyngeal Swabs Suitable as Samples for Legionella-Specific PCR Testing?. J. Clin. Microbiol. 45: 3482-3483 [Full Text]  
  • (2007). Poster Abstracts. J. Nutr. 137: 278S-295S [Full Text]  
  • Templeton, K. E., Scheltinga, S. A., Sillekens, P., Crielaard, J. W., van Dam, A. P., Goossens, H., Claas, E. C. J. (2003). Development and Clinical Evaluation of an Internally Controlled, Single-Tube Multiplex Real-Time PCR Assay for Detection of Legionella pneumophila and Other Legionella Species. J. Clin. Microbiol. 41: 4016-4021 [Abstract] [Full Text]  
  • Evans, G. E., Murdoch, D. R., Anderson, T. P., Potter, H. C., George, P. M., Chambers, S. T. (2003). Contamination of Qiagen DNA Extraction Kits with Legionella DNA. J. Clin. Microbiol. 41: 3452-3453 [Full Text]  
  • Rantakokko-Jalava, K., Jalava, J. (2002). Optimal DNA Isolation Method for Detection of Bacteria in Clinical Specimens by Broad-Range PCR. J. Clin. Microbiol. 40: 4211-4217 [Abstract] [Full Text]  

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van der Zee, A.
Right arrow Articles by Templeton, K. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van der Zee, A.
Right arrow Articles by Templeton, K. E.