Journal of Clinical Microbiology, August 2002, p. 2908-2912, Vol. 40, No. 8
0095-1137/02/$04.00+0 DOI: 10.1128/JCM.40.8.2908-2912.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
Department of Laboratory Medicine,1 Department of Microbiology, University of Washington,3 Washington State Public Health Laboratories, Seattle, Washington2
Received 29 January 2002/ Returned for modification 5 April 2002/ Accepted 13 May 2002
|
|
|---|
|
|
|---|
The diagnosis of pertussis has been problematic (17). Although culture of pertussis is highly specific and often considered the diagnostic standard, sensitivity has been reported to be as low as 25 to 50% when judged against serology (9, 10). Direct fluorescent-antibody (DFA) assay has been found to be prone to false-positive results (6), and although serodiagnosis can be sensitive and specific (20), its requirement of a convalescent-phase specimen makes serology of minimal clinical utility.
Several PCR assays for the diagnosis of pertussis infection have been developed, and clinical studies have compared the sensitivity and specificity of these PCR tests to culture, serology, and DFA assay. In general, pertussis PCR has been found to be as or more sensitive than culture, although the reported sensitivity of various pertussis PCR assays versus serologic evidence of infection has ranged from 21 to 61% (11, 19, 21). More recently, real-time PCR assays have also been reported (7, 18). However, it is difficult to compare different studies which used PCR diagnosis, since many studies differ in DNA purification techniques, PCR primers, reaction conditions, and product detection methods. In particular, there have been no studies with clinical specimens that directly compare the most commonly employed product detection techniques of gel electrophoresis (using agarose or polyacrylamide) and dot blot hybridization. Furthermore, few studies have examined the utility of specific PCR diagnostic assays in the context of routine clinical diagnostic testing. Clinical diagnosis with routinely collected specimens is complicated by lower incidence rates, leading to a lower positive predictive value for diagnostic assays than would be encountered in a high-incidence population experiencing a pertussis outbreak.
A PCR assay for B. pertussis based on detection of the pertussis-specific multiply repeated IS481 sequence has been previously described (8, 12, 14). A PCR assay based on this method was first used at the Washington State Department of Health (DOH) in 1996. By 1997, this assay, in conjunction with culture and DFA analysis, was used for the routine detection of B. pertussis. We were interested in assessing the comparative sensitivities and specificities of this PCR assay with those of culture and DFA assay among the routine clinical respiratory swabs. In addition, since agarose gel electrophoresis detection of PCR products is not sequence specific, we compared this method (PCR-gel) to a highly sensitive and sequence-specific dot blot hybridization assay with a 32P-labeled oligonucleotide probe.
|
|
|---|
Between 1 January and 28 February 1998 all clinical swabs sent by private physicians or community or public health clinics to the DOH for pertussis evaluation were stored at -20°C after routine processing. After storage for <2 months at -20°C, the swabs were randomly divided between each of two study site labs (site 1 and site 2) and processed independently for DNA by personnel proficient in molecular biology techniques. DNA aliquots were shared between the sites to allow PCR studies for each swab to be independently performed at each site. PCR-gel product detection was performed at both sites and dot blot hybridization was performed at one site (site 2).
Specimen processing. Swabs were placed in 1.5-ml Eppendorf tubes, and the swab handles were cut with clean scissors distal from the swab itself. Swabs were then solubilized and processed with QiaAmp kits (Qiagen, Inc., Valencia, Calif.) by using buffers included in the kits and following the manufacturer's tissue extraction procedure.
PCR primers and hybridization probes. Standard purity synthetic deoxynucleotide primers were purchased (Gibco-BRL, Inc./Invitrogen Corp., Carlsbad, Calif.) and dissolved to concentrations of 1 mM in distilled water. Primers for amplification of the IS481 B. pertussis-specific repeat sequence were BP1 (5'-GATTCAATAGGTTGTATGCATGGTT-3') and BP2 (5'-AATTGCTGGACCATTTCGAGTCGACG-3'). Amplification of the human globin gene as an internal positive control was performed with primers HG1 (5'-CAACTTCATCCACGTTCACC-3') and HG2 (5'-GAAGAGCCAAGGACAGGTAC-3'). An oligonucleotide probe, 5'-ACACCCATAAGCATG-3', was synthesized for specific dot blot detection of amplification products from the B. pertussis IS481 gene. A probe for dot blot detection of amplification products from the human globin gene was also synthesized (5'-AGAGCCATCTATTGC-3') and used for a limited number of specimens, but dot blot hybridization with the globin probes was not performed systematically for all specimens.
The specificities of primers and probes were evaluated by performing PCRs on 1 ng of genomic DNA isolated from clinical Bordetella spp. isolates (B. pertussis, B. parapertussis, and B. holmesii) and from clinical isolates of organisms identified as potential respiratory tract colonizers or pathogens, including Archanobacterium pyogenes, Bacillus fragilis, Escherichia coli, Enterobacter cloacae, Enterococcus faecium, Haemophilus influenzae, Legionella pneumophila, Mycoplasma pneumoniae, Moraxella catarrhalis, Peptostreptococcus spp., Staphylococcus aureus, and Streptococcus pyogenes (group A). The sensitivities of primers and probes were evaluated with serial dilutions of pertussis genomic DNA starting at 40 pg (10 genome equivalents) and diluting to 0.04 pg (0.01 genome equivalents).
As a result of the target being multiply repeated, the IS481 B. pertussis PCR assay used in this study is highly sensitive with a detection limit of
1 to 0.5 genome equivalents by agarose gel electrophoresis and 0.5 to 0.1 genome equivalents by dot blot analysis (data not shown). PCR amplification was detectable only from B. pertussis and the closely related B. holmesii but not from B. parapertussis or other respiratory pathogens and commensals. This finding has been previously reported (15).
PCRs. PCRs were performed in 25-µl volumes with 0.2 mM (each) dATP, dGTP, dCTP, and dUTP, 2.5 µl of Taq buffer, 5.0 µl of Qiagen Q-solution, 0.2 µl of Taq polymerase (Qiagen, Inc.), and 0.5 µM primer. Uracil DNA glycosylase (0.25 µl) (New England Biolabs, Beverly, MA) was added to each reaction mixture to reduce the risk of contamination with PCR products (16). The reaction mixtures were multiplexed with all four primers (BP1, BP2, HG1, and HG2), and PCR was performed with a Perkin Elmer 6600 (site 1) or an Ericomp thermocycler (site 2) with one 10-min denaturation step at 94°C, 30 cycles of amplification of 1 min at 94°C, 30 s at 60°C, and 45 s at 72°C, and a final 5-min extension at 72°C. PCR analysis was performed independently at each site; the number of repeated runs for a given specimen at each site depended on the consistency of the results obtained for that sample and the amount of specimen remaining. Overall, PCR was performed on each specimen at each site at least once and up to four times, with detection by gel electrophoresis at both sites as well as by dot blot hybridization at site 2. Multiplexed PCRs with high levels of pertussis amplification were repeated with human globin primer pairs alone. A negative-control reaction mixture with water substituted for specimen DNA was included after every fourth clinical specimen reaction mixture. One positive-control reaction mixture with 1 genome equivalent of B. pertussis genomic DNA was included for each PCR run.
PCR product detection. (i) Agarose gel. The 154-bp pertussis and 268-bp human globin amplification products were separated on a 1% Metaphor agarose gel (FMC Corporation, Philadelphia, Pa.) in TAE buffer (50x TAE is 242 g of Tris base, 57.1 ml of glacial acetic acid, and 100 ml of 0.5 M EDTA, pH 8.0) with 10 µl of PCR product and 2 µl of loading buffer (0.25% bromophenol blue, 0.25% xylene cyanol FF, 30% glycerol) and run at 100 V for 30 min; clinical specimens and negative controls were loaded onto gels in the same order that they were manipulated for PCR. Gels were stained for 15 min in 0.5 mg of ethidium bromide/ml, destained for 30 min in water, and visualized on a UV transilluminator.
(ii) Dot blot hybridization. After PCR-gel analysis, 6 µl of PCR product was denatured with 0.6 µl of denaturing solution (3.6 N NaOH, 1 µl of 1-mg/ml sheared salmon sperm DNA). From this mix, 2 µl was spotted on GeneScreen nylon membranes (New England Nuclear/Perkin Elmer Life Sciences, Boston, Mass.), which were cross-linked on a UV irradiator (Stratagene, La Jolla, Calif.). Prehybridization was done in 0.8 M NaCl, 0.2 M Tris-Cl (pH 8.0), 0.05 M EDTA-Na2, 1% sodium dodecyl sulfate, and 0.5% nonfat milk. Specific oligonucleotides were 5' end labeled with [32P]ATP (New England Nuclear/PerkinElmer Life Sciences) and polynucleotide kinase (New England Biolabs, Beverly, Mass.) at 37°C for 30 min, with a final specific activity of 3 x 105 to 5 x 105 counts/min/µg. Hybridization was performed for 2 h at 30°C in prehybridization buffer with 0.1 to 0.3 pM of specific labeled oligonucleotide. Filters were washed three times for 10 min each in 0.1x SSC (1x SSC is 0.15 M NaCl plus 0.015 M sodium citrate) (pH 7.0) with 1% sodium dodecyl sulfate at 34°C and exposed to Kodak XAR-5 film. We assessed detection sensitivity by using 8-h (short) and 24-h (long) exposures. Individual short- or long-exposure dot blot signals were classified as positive if the signal was greater than the signal from PCR-negative controls or classified as negative if the signal was less than that of the controls.
Clinical symptoms. Clinical symptoms reported by the patients were collected from the request slips that accompanied the swabs and entered into the lab result database; the date of symptom onset was generally not available. Variables were created to identify cases in which cough or chronic cough were reported or in which the patient had a positive test for respiratory syncytial virus (RSV) (no details on the type of test were obtained from the request slips).
Data analysis.
Results from multiple gel runs at each testing site and short or long exposure dot blot analyses at one testing site were combined into final results as follows. (i) Results were first analyzed by a specific detection method: PCR-gel, dot blot with short exposure, or dot blot with long exposure. A specimen was positive by a specific detection method if >2 PCR runs had been performed and the pertussis amplicon was detected by that method in
50% of the runs. If only 2 runs were performed, specimens were classified positive, indeterminate, or negative if pertussis amplicons were present on both, one, or no runs, respectively. If both globin and pertussis PCR results were negative by electrophoresis, the specimen was classified as inadequate. (ii) PCR results from short- and long-exposure dot blots were then combined into a final dot blot result. If the results of the short and long exposures were in agreement, then that result was used as the final dot blot result. If the short exposure result was negative and the long exposure result was positive, the final dot blot result was positive. If the short exposure result was positive and the long exposure result was negative or indeterminate, the final result was indeterminate. In the event of an indeterminate short exposure, the final result would be classified as indeterminate, except if the long exposure were positive, in which case the final result would be positive.
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. PCR, culture, and DFA assay results
|
Seven specimens demonstrated the presence of high levels of pertussis amplification and the absence of globin on multiplex PCR; all seven demonstrated the 268-bp globin amplicon when tested by globin PCR alone. For specimens that had high levels of globin amplification on multiplex PCR, no discrepancies in pertussis results were noted even when PCR was repeated with pertussis primers alone. No contamination was present, as measured by the absence of the 154-bp pertussis band in 203 negative-control specimens.
When results of gel electrophoresis detection at both sites were combined, 10 of 225 specimens were positive for pertussis.
Based on negative electrophoresis results for both pertussis and globin PCR products, 47 of 225 specimens were classified as inadequate for PCR.
PCR with detection by dot blot hybridization. Repeat dot blot assays for pertussis were performed on each specimen two to four times (a mean of three repeats for long exposures and two repeats for short exposures). Six hundred eighty-five PCR assays were tested with short exposures (8 h), and 455 PCR assays were tested with long exposures (24 h). Results differed from the majority of results for the same specimen in 34 of 685 (5%) of the short exposures and in 13 of 455 (2.8%) of the long exposures.
Thirty-one specimens were identified as positive by either short- or long-exposure dot blot analysis. Two specimens positive by long exposure but negative by short exposure were classified as dot blot positive. No specimens had an indeterminate short-exposure result with a positive long-exposure result. When short- and long-exposure results of dot blot hybridization assays were combined, 30 of 225 specimens were positive for the pertussis PCR amplicon. One specimen with a positive short-exposure result and a negative long-exposure result was given a final dot blot classification of indeterminate. The indeterminate specimen was associated with negative-pertussis and positive-globin PCR-gel results with two of four short-exposure dot blots interpreted as positive and both long-exposure results classified as negative. One of the 47 specimens initially classified as inadequate for PCR by gel electrophoresis was positive on two of four short-exposure dot blots and two of four long-exposure dot blots. This specimen was therefore reclassified as positive by pertussis dot blot and therefore adequate for PCR; thus, based on gel and dot blot detection, 179 specimens were adequate for PCR.
Dot blot detection with the globin oligonucleotide probe was only performed on a small number of specimens, including some specimens that were negative by gel detection. The globin hybridization results for those specimens tested did not differ from the PCR-gel results (data not shown), possibly reflecting the difference in copy number for the two genes (2 copies of the globin gene per human haploid cell and 80 copies of the IS481 insertion sequence per pertussis cell) and characteristics of the PCR and probe hybridization.
Comparison of conventional culture, DFA assay, PCR-gel, and PCR dot blot analysis. Table 2 summarizes the relationships among the overall results obtained from the different testing methods. Among the nine adequate specimens that were culture positive for B. pertussis, eight were positive by pertussis PCR (either gel or dot blot detection) and one was negative. Two PCR-gel-positive specimens were negative on culture. Dot blot detection identified 22 positive specimens that were culture negative; 20 of these were negative by PCR-gel. All specimens positive by PCR-gel were also positive by PCR dot blot analysis. Of three adequate specimens in which culture and PCR-gel results were discordant, two (one PCR positive and one culture positive) had a DFA assay performed with negative results for both (data not shown). A fourth specimen with discordant culture and PCR-gel results (culture positive and PCR-gel negative) was found to be inadequate for PCR analysis. The overall sensitivities of specimens adequate for PCR analysis by DFA assay, PCR-gel detection, and PCR dot blot detection were 44, 89, and 89%, respectively, of those for culture detection. The sensitivity of the DFA assay was 44 and 15% of that found for gel and dot blot detection, respectively (data not shown). The detection sensitivity of culture was 80 and 27% of that found for PCR-gel and PCR dot blot detection, respectively.
|
View this table: [in a new window] |
TABLE 2. Comparison of DFA, PCR, and culture assays for specimens considered adequate
|
|
View this table: [in a new window] |
TABLE 3. Comparison of pertussis laboratory test results and clinical findings (n = 95)
|
|
|
|---|
In this report we compare the laboratory test results of four different assays for B. pertussis with 225 community-acquired clinical specimens. When assessed without regard to the adequacy of the specimen for PCR, the sensitivities of culture with PCR-gel detection as a "gold standard" and PCR-gel detection with culture as a "gold standard" were both 80%. Among specimens identified as adequate for PCR analysis, gel electrophoresis detection of pertussis PCR amplicons had a sensitivity of 89% of that of culture, whereas the sensitivities of culture versus gel and dot blot detection of PCR amplicons were 80 and 27%, respectively. The sensitivity of the DFA assay was 44% of that of culture and PCR with gel detection; the sensitivity of the DFA assay was 15% of that of PCR with dot blot detection. The low sensitivity of DFA is notable since the assay performed here was based on a monoclonal antibody. These data, therefore, reemphasize the insensitivity of this assay compared to either culture or PCR and underscore that it should only be used in conjunction with other assays.
Despite the higher sensitivity of PCR with agarose gel detection than that of culture among specimens deemed adequate for PCR, at least one specimen in our cohort was negative for pertussis by PCR but positive by culture. This is slightly lower than, but consistent with, the results of previous studies that found 2% of specimens were negative for B. pertussis culture but positive for pertussis PCR (17). Furthermore, over 20% of all specimens in this study were deemed to be inadequate for PCR analysis. Since at least one of these specimens was culture positive for B. pertussis, specimen inadequacy can have a significant impact on measured PCR sensitivity and could explain some of the differences in PCR sensitivity reported in the literature. We cannot determine if inadequate specimens arose from compromised specimen collection or inefficient specimen extraction or if streaking the swab for culture reduced the specimen quality for subsequent PCR analysis. Regardless of the explanation, these data suggest that clinical laboratories performing PCR assays for pertussis should consider routinely monitoring specimen adequacy. Furthermore, PCR sensitivity would likely be higher if two swabs are collected simultaneously from each patient (possibly from opposite nares) with one processed for culture and one processed for PCR. These results also suggest that, particularly in the absence of a routine assay for specimen adequacy, at this time PCR should not replace culture in the routine diagnosis of pertussis.
We analyzed our data to assess the reproducibility of the pertussis and globin PCR assays performed at each participating site. The higher variability found with the globin assay is likely due to the high copy number of the IS481 sequence in the pertussis genome. Although overall test results were generally highly reproducible, significant differences in rates of discrepant results were noted between the sites. We conclude that periodic and standardized determination of PCR assay reproducibility is therefore an important quality control mechanism that should be considered in any clinical laboratory planning to use PCR for clinical diagnosis of pertussis.
We placed a high emphasis on limiting contamination during PCR analysis through the use of barrier (laminar flow hood, filtered pipette tips, and frequent glove changes) and enzymatic (uracil glycosylase) methods. As a result, none of the more than 200 negative-control specimens run during this study were found to be positive by any detection method. In view of this lack of cross-contamination, it is highly significant that pertussis-specific dot blot hybridization detected nearly three times the number of positive specimens as identified by either PCR-gel or culture. These results may represent the enhancement of the sensitivity of PCR to detect organisms at a point when they are no longer culturable (21). Alternatively, the high number of positive PCR results by dot blot detection may suggest the presence of colonizing organisms at a level not detectable by standard culture. Although we did not find any difference in clinical symptoms exhibited by persons testing positive for pertussis by each of our assays, with only 35% of adequate specimens having an associated cursory clinical history, our data are insufficient to assess the relationship of PCR dot blot positivity to clinical symptoms. Bordetella bronchiseptica is known to colonize dogs (5), and detection of canine colonization with B. pertussis has recently been reported (1). While pertussis colonization in humans would not represent a significant clinical problem to the colonized individual, it could have more-significant public health implications, particularly if colonization did occur and was not affected by vaccination. Larger prospective studies of pertussis PCR with dot blot detection are needed to further understand these findings.
|
|
|---|