Previous Article | Next Article ![]()
Journal of Clinical Microbiology, May 2003, p. 1888-1893, Vol. 41, No. 5
0095-1137/03/$08.00+0 DOI: 10.1128/JCM.41.5.1888-1893.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.
New England Research Center, Waltham, Massachusetts,1 Rush-Presbyterian Hospital, Chicago, Illinois,2 University of Alabama, Birmingham, Alabama,3 New England Newborn Screening Program, University of Massachusetts, Boston, Massachusetts,4 Africa Centre, Durban, South Africa,5 University of California, Los Angeles, California,6 Johns Hopkins University, Baltimore, Maryland,7 Columbia University, New York, New York,8 University of Massachusetts, Worcester, Massachusetts,9 Roche Molecular Systems, Pleasanton, California,10 bioMerieux, Durham, North Carolina,11 National Institute of Child Health and Development, Bethesda, Maryland,12 University of North Carolina, Chapel Hill, North Carolina,13
Received 3 July 2002/ Returned for modification 20 September 2002/ Accepted 29 January 2003
|
|
|---|
|
|
|---|
Whole blood dried on filter paper (dried blood spots [DBSs]) has been used to qualitatively detect HIV antibodies (13, 15), HIV DNA (1, 3, 5-7, 9, 10, 11, 12, 16, 18) and HIV RNA (4, 14, 17; J. L. Gerstel and A. M. Comeau, Proc. 10th Natl. Neonatal Screening Symp., abstr. P-19, p. 64, 1994). In addition, dried plasma spots (DPSs) have also been used to quantitate the HIV load (8). Although the stabilities of antibodies and DNA in DBSs have been determined (2, 6, 13), there has been some question regarding the stability of the HIV RNA when it is dried and stored at room temperature (14, 17).
The purpose of this study was to compare two different methods for quantitatively measuring HIV RNA in DBSs and DPSs and to assess their long-term stability at room temperature and at -70C.
(This study was presented in part at the 12th World AIDS Conference, Geneva, Switzerland, 28 June to 3 July 1998 [S. Cassol, A. Comeau, S. Fiscus, G. Aldrovandi, J. Sullivan, J. Bremer, and B. Jackson, Abstr. 12th World AIDS Conf., abstr. 33166, 1998].)
|
|
|---|
Panel 1 consisted of seronegative plasma and whole blood, to which fivefold serial dilutions of a well-characterized HIV type 1 (HIV-1) stock with from 0 to 500,000 copies/ml was added (nominal concentrations). Each specimen was tested in duplicate by the participating laboratories, and each panel was tested at two different time points (panels 1A and 1B).
Panels 2 and 3 each consisted of liquid plasma, DPSs, and DBSs from three HIV-1-infected patients and one uninfected patient, all in triplicate. For the six HIV-1-infected patients (three different patients for each of the two panels), the nominal concentrations determined by the Virus Quality Assurance Laboratory by the Roche Diagnostics (Branchburg, N.J.) Amplicor HIV-1 Monitor assay with liquid plasma were as follows: for panel 2, 1,157, 16,620, and 231,040 copies/ml, respectively; for panel 3, 1,064, 99,980, and 65,332 copies/ml, respectively.
Panel 3 was designed to evaluate the stability of HIV RNA in DBSs and DPSs during storage at room temperature and -70°C. Each panel consisted of triplicate blood or plasma spots from four HIV-infected patients (12 spots for each panel). One complete set (blood and plasma) was assayed at baseline. Four sets (samples B and D) were placed in storage at room temperature, and the other four sets (samples C and E) were stored at -70°C. One set of blood and plasma spots from each storage condition was assayed after 2, 4, 26, and 52 weeks of storage.
HIV-1 RNA assays. Assays for detection of HIV-1 RNA were conducted over a 3-year period (September 1997 to June 2000), and multiple kit lots were used. Three (panels 1A, 1B, and 2) or four (panel 3) laboratories used the NucliSens HIV-1 QT assay (bioMérieux, Inc. [formerly Organon Teknika], Durham, N.C.) with minor modifications. One DPS or DPS was placed in 9 ml of NucliSens lysis buffer and rocked at room temperature for 2 h to elute the RNA from the filter paper. Once the filter paper was removed, the manufacturer's instructions were followed for the remainder of the procedure.
Five (panels 1A and 1B) or six (panel 2) laboratories used a modified Amplicor HIV-1 Monitor assay (version 1.0; Roche Diagnostics) to quantitate the RNA in the blood and plasma spots. HIV RNA was eluted from the filter paper by treatment with a chaotrope, organic reagent, and detergent (CORD) solution consisting of 33% (vol/vol) buffered phenol (pH 4.3), 1.34 M guanidinium isothiocyanate, 0.2% (vol/vol) Sarkosyl, 0.3% (vol/vol) sodium dodecyl sulfate, 0.2% (vol/vol) mercaptoethanol, 0.6% (wt/vol) glycogen, and 8 mM sodium citrate. The DBS or DPS was cut or punched into small pieces and incubated in 0.75 ml of CORD reagent containing 0.5 µg of tRNA and 3.3 µl of the kit quantitation standard at 56°C, with shaking, for 30 min. The RNA was then extracted from the mixture with chloroform, followed by alcohol precipitation and elution with the HIV-1 Monitor specimen diluent (100 µl). Amplification and detection of the extracted RNA (50 µl) were performed according to the manufacturer's guidelines. The CORD reagent was prepared by Roche Molecular Systems and distributed to the laboratories that used the HIV-1 Monitor assay.
Statistical methods. Data from the three panels were transformed to base 10 logarithms for analysis. The data for the HIV-negative specimens were excluded from all of the analyses. Data from the NucliSens and Monitor assays were analyzed separately. Linear regressions of the log10 estimated HIV RNA concentration on the log10 nominal HIV RNA concentration were used to analyze the data for panels 1A and 1B. The analysis was restricted to six laboratories from which results were obtained for both rounds of testing (Monitor assay, four laboratories; NucliSens assay, two laboratories). Predictor variables were added to the model to test for variations in the results between DBSs and DPSs, between the two panels, or among laboratories. More complex predictors were added to determine if differences between panels or between specimen types varied over laboratories or if any of the differences varied with nominal concentration.
Analysis of variance was used for panel 2. Indicator variables for the donor were included in all models. Hematocrit-corrected estimates of the concentrations from DBSs with those from DPSs were compared with estimates of the concentrations from plasma in separate analyses. Predictors were added to the models to determine if differences between specimen types varied among donors or laboratories.
The stability of HIV RNA in stored DBSs and DPSs was assessed by using regressions on the log10 estimated RNA concentration on time in storage and donor to model the results for panel 3. The analysis was stratified by specimen type (DPSs versus DBSs) and storage condition (room temperature versus -70°C) to form four separate regressions. Variables were added to the models to determine if the rate of change in HIV RNA concentration in storage varied among donors or laboratories.
In some cases, results that were below the limit of detection of an assay were included in an analysis. Estimates that were below the limit of detection for the NucliSens kit were set at 400 copies/ml. Estimates that were below the limit of detection for the Monitor test were set at values that were calculated by substituting an optical density of 0.2 units for the optical density for the undiluted amplified sample. This is the minimum RNA concentration that would have produced a positive result by the Monitor test, given the results for the internal quantitation standard in each assay.
|
|
|---|
The samples with nominal concentrations of 800 copies/ml were excluded from the statistical comparisons of estimates of the concentrations from DBSs and DPSs because nearly half of the results were below the limits of detection of the two kits (NucliSens assay, 8 of 12 from DPSs and 7 of 12 from DBSs; Monitor assay, 9 of 19 from DPSs and 7 of 21 from DBSs). Results at a nominal concentration of 4,000 copies/ml that were below the limit of detection of the assay were included in the analysis, as described earlier (Nuclisens assay, 4 of 12 from DPSs and 2 of 12 from DBSs; Monitor assay, 1 of 22 from DPSs and 3 of 21 from DBSs).
Log-log plots of the estimated HIV RNA concentrations from DBSs against the nominal RNA concentrations are shown separately for the NucliSens assay (Fig. 1A) and the Monitor assay (Fig. 1B). On average, estimates by the NucliSens assay for panel 1A were 0.11 log10 (29%) higher than estimates for panel 1B (P = 0.011), and the results from DBSs were, on average, 0.11 log10 (29%) higher than those from DPSs. There was no evidence that the differences between log-transformed estimates of the concentrations from the two panels or two specimen types varied among nominal concentrations or among laboratories.
![]() View larger version (18K): [in a new window] |
FIG. 1. Log10 estimated HIV RNA concentrations plotted against log10 nominal HIV RNA concentrations for the NucliSens and Monitor assays. Panel 1 specimens were tested on two different occasions (round A and round B). The horizontal line represents the median estimated concentration at each nominal concentration.
|
Log-log plots of median hematocrit-adjusted estimated HIV RNA concentrations from DBSs in panel 2, for each donor in each laboratory, against the median for plasma, for data combined across laboratories, are shown separately for the NucliSens assay (Fig. 2A) and the Monitor assay (Fig. 2B). By the NucliSens assay, the hematocrit-corrected estimates of the concentrations from DBSs were, on average, 0.078 log10 (16.5%) lower than those from plasma (P = 0.16), with no detectable variation in the difference among laboratories (P = 0.39) or donors (P = 0.49). Similar results for panel 2 were seen for the comparison of DPSs and plasma by the NucliSens assay (data not shown).
![]() View larger version (22K): [in a new window] |
FIG. 2. Results for panel 2 showing the median log10 hematocrit-adjusted (Hct Adj.) estimated HIV RNA concentrations in DBSs in each laboratory plotted against the median log10 estimated HIV RNA concentrations in plasma for all laboratories in which the same kit was used. The dotted line represents the line of equivalence.
|
Panel 3 was designed to evaluate the effects of long-term storage on RNA levels in DBSs and DPSs (Fig. 3) and was tested only by the NucliSens assay. Data through 52 weeks of storage were obtained from three laboratories, and data through 26 weeks of storage were obtained from a fourth laboratory. The results for one of three HIV-infected donors were excluded because 40% of the values were below the limit of detection of the assay. Values below the limit of detection were obtained for DBSs and DPSs stored at both temperatures and for DBSs and DPSs at all time points for this donor.
![]() View larger version (21K): [in a new window] |
FIG. 3. Median log estimated RNA concentrations for DBSs versus time (weeks) in storage. The effect of storage at room temperature (left) or at -70°C (right) for DBSs was tested by the NucliSens assay. Each symbol is the median for one patient at a given time point in a given laboratory. The line segments join the medians for data from all laboratories combined.
|
|
|
|---|
Variation in the Monitor assay made analysis difficult, and the sources of this variation were difficult to pinpoint. The variability might be due to the modified RNA extraction method that had to be used for the dried spots. Phenol-chloroform extractions are more technically demanding, and differences in the recovery of the appropriate phase during the extraction may affect HIV RNA recovery. Potential sources of variation include the retention of various levels of inhibitors such as heme and iron, errors during the RNA extraction, and reagent or kit variability. Furthermore, the reagents used for the modified Monitor extraction method were in their initial stages of development and, hence, were not completely optimized. To the best of our knowledge, Roche no longer supports this application and these reagents are not available commercially.
On the other hand, the Monitor assay appeared to be somewhat more sensitive, particularly in detecting specimens with lower viral loads. This is probably a function of the differences in the amount of the actual RNA eluate that went into the amplification steps for the two assays. For the Monitor assay, the RNA was eluted in 100 µl of diluent and half was used for amplification. The specimen input for the plasma spot was equivalent to 25 µl, a volume comparable to that used for the standard Monitor assay. The NucliSens assay elutes the RNA into 50 µl of diluent, but only 5 µl is used for amplification. The specimen input for the plasma spot was equivalent to 5 µl, which is 1/4 to 1/20 the volume used for plasma analysis by the NucliSens assay. The NucliSens assay could potentially be made more sensitive by reducing the elution volume used during the extraction.
HIV RNA was stable in DBSs and DPSs stored at room temperature and at -70°C for at least 1 year (Fig. 3), and possibly longer. The differences observed in our experiments were probably due to factors such as interassay variation and/or lot-to-lot variation in the kits and are not considered to be clinically significant. Interassay variation would account for the small positive changes if results in a given laboratory were unusually low at early time points or unusually high at later time points, as was the case in some laboratories. These data confirm those of O'Shea et al. (17) regarding the stability of HIV RNA dried on Guthrie cards. Previous results suggesting that HIV RNA was lost with increasing time of storage (14) was probably due to differences in the paper used.
Although the sensitivity of an RNA assay with DBSs may never reach the sensitivity of an assay with whole plasma, it may still be sensitive enough given recent changes in treatment guidelines (patients should be treated when viral load is >50,000 copies/ml or when the CD4 count is <350 cells/mm3). In this study we were able to reliably measure viral loads of 4,000 copies/ml or greater. The potential to improve this sensitivity exists and may be warranted. DBSs offer an easy and inexpensive means for the collection and storage of blood, since they are stable and noninfectious and can easily be sent to centralized testing laboratories for analysis. DBSs clearly provide the perfect means for the collection of specimens under field conditions for the diagnosis of HIV infection and the monitoring of antiretroviral therapy and vaccine efficacy.
We thank Kevin Byron, Don Decker, Jim Ellerbrock, Jacalyn Gerstel-Thompson, Michelle Janes, Richard Pilon, Jana Parsons, Jody Schock, Sal Scianna, and Art Sunhachawee for expert technical assistance and Suzanne Granger for statistical and graphic expertise.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»