Previous Article | Next Article ![]()
Journal of Clinical Microbiology, April 2004, p. 1719-1722, Vol. 42, No. 4
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.4.1719-1722.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Laboratoire de Parasitologie-Mycologie, Centre Hospitalier Universitaire,1 Faculté de Médecine, UMR5093 "Génome des Protozoaires Parasites,",2 CNRS/Université Montpellier I, Montpellier, France3
Received 9 May 2003/ Returned for modification 20 July 2003/ Accepted 11 January 2004
|
|
|---|
1 Toxoplasma genome per reaction tube). Nevertheless, when clinical samples were tested, both methods significantly differed in their technical sensitivities and specificities. Only one method appeared adequate for samples containing blood or tissue. |
|
|---|
Human clinical samples were received from gynecology and obstetrics departments throughout the region of Languedoc (Southern France) and from the Infectious Diseases Department of the Centre Hospitalier Universitaire of Montpellier during routine PCR diagnosis for toxoplasmosis. A total of 96 samples were selected to be tested with both PCR methods: 21 amniotic fluid (AF), 38 placenta, 17 cord blood, 15 peripheral blood, and 5 miscellaneous (liver biopsy, aqueous humor, cerebrospinal fluid, and sputum) samples. In addition, negative control samples (10 AF and 6 placenta samples) were obtained from women who were either nonimmune or presented with long-standing immunity against toxoplasmosis and for whom a diagnosis of recent toxoplasmosis was ruled out.
AF samples were prepared as described previously (13). Peripheral blood was collected, and the buffy coat portion was prepared as reported earlier (17). Placentae (300 g) were ground, trypsinized, filtered, and washed three times in 0.9% NaCl. Buffy coat (300-µl) and ground-placenta (1-ml) samples were lysed in 2 and 3 volumes, respectively, of TNN lysis buffer (0.5% Tween 20, 0.5% Nonidet P-40, 10 mM NaOH) with 10 mM Tris and 320 µg of proteinase K/ml for 3 to 16 h. The DNA was extracted by a simplified phenol-chloroform method (17), which was shown by previous comparative experiments to be as efficient as commercial extraction kits (reference 18 and data not shown).
For the preparation of Toxoplasma DNA and mimic samples, ascitic fluid containing tachyzoites was drawn from a Swiss-Webster female mouse infected with the RH strain of Toxoplasma gondii. Parasites were precisely counted and prepared according to a simplified method (13); the DNA was then diluted in distilled water for a Toxoplasma DNA serial dilution assay (SDA). Mimic AF and placenta samples were prepared by extracting a pool of known Toxoplasma-negative samples under sterile conditions and adding various amounts of Toxoplasma DNA. Mimic blood samples were prepared as described previously (17), except that the buffy coat was prepared and the DNA was extracted as described above, and aliquots of this DNA were then mixed with various dilutions of Toxoplasma DNA. For the SDA and the three types of mimic samples, the aim was to test the DNA equivalent of 25, 10, 5, 2, 1, 0.5, 0.1, 0.05 and 0.01 parasite genome(s) per PCR tube.
As described above, PCR amplification was carried out in two separate assays using different primer sets (4, 6). The reaction conditions of both assays, termed methods T and B, were independently and thoroughly optimized in the presence of human DNA as described elsewhere (17). The optimized PCR conditions for method T were the following: 5 µl of 10x buffer, 0.6 mg of bovine serum albumin ml1, deoxynucleoside triphosphates at a concentration of 200 µM each, 2 mM MgCl2, 50 pmol of each primer, and 1.5 U of Taq DNA polymerase (Goldstar; Eurogentec), for a total volume of 50 µl including 5 µl of sample DNA. For the B22-B23 primer set, the optimized conditions were identical except that the amounts of primers and Taq polymerase were 10 pmol and 1 U, respectively. The hot-start technique (Dynawax; Eurogentec) was used to increase specificity. The reaction mixtures were cycled in an M.J. Research PTC-100 thermal cycler by using the following conditions: 94°C for 3 min; 40 cycles of 94°C for 30 s, 57°C (for primer set T1-T4) or 59°C (for primer set B22-B23) for 30 s, and 72° for 30 s; and 72°C for 10 min. All samples were tested in quadruplicate and, for some mimic samples, additional replicate experiments were performed to precisely determine the detection limits of the methods. In addition, for each sample, one internal control tube was included for detection of PCR inhibition; it consisted of a minimal amount of purified parasite DNA (equivalent to 0.8 Toxoplasma genome) added to the 5 µl of sample DNA. Three negative control tubes that each received 5 µl of H2O instead of DNA were included in each test to detect carryover contaminations. Extreme physical separation and decontamination procedures (17) were used to avoid contaminations by amplicons.
The reaction products were visualized under UV light after electrophoresis in a 3% agarose gel. The expected fragment sizes were 194 and 114 bp for the T1-T4 and B22-B23 primer methods, repectively. All gels presenting bands of the expected sizes were subjected to Southern blot analysis and hybridized with an
-32P-labeled B1 gene-specific DNA probe in order to check the specificity of the amplified product. The B1 probe was a generous gift from John Boothroyd and Eduardo Ortega-Barria of the Stanford University School of Medicine (16). It consisted of a 2.2-kb EcoRI genomic DNA fragment comprising a single repeat from the B1 gene. A result was considered positive when one reaction yielded an amplification product hybridizing to the specific DNA probe.
In some instances, PCR products were gel purified by electroelution and cloned into the pGEMT plasmid vector (Promega), and their nucleotide sequences were determined in both directions from double-stranded DNA by use of dye-primer technology with a Vistra (Amersham) automated sequencer. Raw sequences were submitted to BLASTN searches in the GenBank database.
Toxoplasma SDA. The analytical sensitivities of both assays, determined by a Toxoplasma SDA, were very similar and indeed quite high, i.e., at least 0.5 (and as low as 0.05) parasite genome equivalent (PGE) per reaction tube. Below 0.5 PGE per reaction tube, both assays gave inconsistent though reproducible results, i.e., only a portion of the reactions was positive, thus defining the detection limit of these methods. This finding implies that, at these low concentrations, more reactions must be carried out in each experiment to affirm a positive PCR (7, 18, 19). At 0.1 PGE and more so at 0.05 PGE per reaction tube, method B (with six and four positive reactions, respectively, out of eight) performed better than method T (with four and eight positive reactions, respectively, out of eight). None of the methods detected 0.01 PGE.
Comparison of two PCR methods using artificial human samples. In order to mimic nonideal conditions of clinical laboratory practice and analyze the effect of host DNA upon the performances of both methods, we then thoroughly optimized the methods with AF DNA as well as placenta and blood DNA. The presence of AF DNA did not alter the performance of either method in comparison to that of the Toxoplasma SDA (Table 1): both methods could consistently detect 0.5 PGE/reaction tube (theoretically corresponding to 2 to 3 PGE per ml of AF) and inconsistently down to 0.05 PGE/reaction tube (0.25 PGE/ml). This result compares well with the best sensitivity estimates reported by other authors (8). The difference between the two methods was more visible when tests were performed in the presence of placenta and blood DNA, even though the level of sensitivity was still high for both, i.e., <1 Toxoplasma genome/reaction. With placenta and blood DNA, the detection limit of method B was fourfold lower than that of method T with regards to constant detection, i.e., 0.5 and 2 PGEs/PCR tube, respectively. Below these values, as in the SDA, the reactions were inconsistently positive, i.e., at 0.1 to 0.05 PGE and 1 to 0.1 PGE per reaction tube for methods B and T, respectively (Table 1). It should be stressed that the intramethod reproducibility of both assays was high with both the SDA and the seeded samples, including those assays with low parasite concentrations.
|
View this table: [in a new window] |
TABLE 1. Comparison of two PCR methods (using artificial samples) in the presence of human DNA
|
Overall, 64 samples were positive by at least one of the two methods. All but 1 sample (98.4%) were positive with method B, but only 48 samples (75%) were positive with method T (Table 2). Regarding AF samples, both methods performed equally well: nine samples were 100% positive and one was weakly positive by both methods. When blood and placenta clinical samples were used, the differences between the methods were much more obvious. Methods B and T detected 98 and 69%, respectively, of all the positive blood- or tissue-containing samples (Table 2). Among those, method T detected only 53% of the weakly positive samples that were detected by method B.
|
View this table: [in a new window] |
TABLE 2. Comparison of two PCR methods for the detection of Toxoplasma in clinical biological samples
|
With regards to specificity, it is essential to note that no contamination of the PCR was observed during or before the course of the study, as inferred from the consistent negativity of
1,500 negative controls as well as that of all the negative control samples. The technical specificity was assessed on the presence of spurious amplification products of the expected size. In this respect, method T proved less specific in the absence of specific DNA probe hybridization. Indeed, 31% of the negative or weakly positive samples exhibited spurious amplification products of the expected size with method T compared to 8% with method B. Moreover, in contrast to method T, method B (i) did not yield spurious amplifications with AF samples and (ii) yielded only false weakly positive results, i.e., in only a proportion of the reactions for a given sample. Spurious products obtained with both methods were cloned, sequenced, and compared against the EMBL nucleotide sequence database: their sizes differed by only a few base pairs from the original products, and their sequences matched nonannotated sequences of human chromosomes 3 and 10 for methods T and B, respectively.
Conclusions. With regards to the prenatal diagnosis of congenital toxoplasmosis by the use of AF, both methods T and B performed equally well and therefore appear adequate; but, with primer set T, an additional step for confirming the identity of the PCR product (which may also be achieved through an enzyme-linked immunosorbent-PCR assay) is of utter importance. For prenatal diagnosis, the fact that both methods perform equally well would tend to validate the current choice of B1 gene-based PCR assays, which, in any case, appear clearly more sensitive than assays targeting the single-copy P30 gene (reviewed in reference 1). In contrast, for the diagnosis of congenital toxoplasmosis at birth or for the diagnosis of toxoplasmosis in immunocompromised patients, we recommend the use of primers B22 and B23 for their higher sensitivity, specificity, and practicability. The additional step mentioned above may still be necessary with these primers, especially in the presence of weak positives (as defined above). On the other hand, the development of more secure and more efficient methods such as real-time PCR should be encouraged (3, 21), as these methods (i) reduce contamination risks, (ii) ensure specificity, and (iii) suppress the cumbersome processing of gels and Southern blots. However, they do not remove the need for a fine optimization of the PCR itself, as shown by the sensitivities usually reported for B1 gene-based real-time PCR assays, with detection thresholds ranging from 10 to 0.75 PGE per reaction depending on the reports (5, 9, 14, 21), i.e., no better than the results presented here. More intralaboratory comparisons and more DNA targets should continue to be investigated to ensure consistent progress in the molecular diagnosis of toxoplasmosis.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»