Previous Article | Next Article ![]()
Journal of Clinical Microbiology, May 2004, p. 1977-1981, Vol. 42, No. 5
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.5.1977-1981.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Stephan Schaefer,1,
and Wolfram H. Gerlich1
Institute of Medical Virology,1 Department of Internal Medicine II, Infectious Diseases Unit, University Hospital, Justus Liebig University, D-35392 Giessen, Germany2
Received 27 June 2003/ Returned for modification 31 August 2003/ Accepted 24 January 2004
|
|
|---|
|
|
|---|
Some efforts have been made to establish real-time protocols for HCV quantification by using the SYBR Green format on LightCycler (17) or the TaqMan technology (8, 10). These published real-time-based techniques are two-step procedures with separate reverse transcription (RT), or they use only the nonspecific SYBR Green for generation of the signal.
One aim of our study was to establish a convenient protocol by using all the options of the LightCycler for improving specificity, such as hybridization probes and a touch-down annealing program for temperature, and to increase the sensitivity by optimized one-tube RT-PCR conditions. After this optimization, the assay was validated with the international standard for HCV RNA and a World Health Organization (WHO) reference panel for HCV genotypes, and results were compared with those of the Roche (Mannheim, Germany) Monitor HCV assay.
HCV particles contain a core protein which most likely encapsidates the viral RNA. Recently, a sensitive enzyme immunoassay (EIA) for detection of the HCV core protein has been developed (2, 18) which detects 1.5 pg of core protein even in the presence of HCV antibodies. It is not clear whether there exists a defined ratio of the number of HCV RNA genomes to the number HCV core protein molecules, but it has been suggested that such an assay of HCV core antigen may be suitable for monitoring of interferon and ribavirin therapy (2, 20). Because conventional RNA quantification methods show a high standard deviation, it is not clear whether the variable ratio of HCV RNA and core antigen is due to the inaccuracy of the assays or whether both have no simple stoichiometric relation. Since our in-house real-time PCR seemed to be very accurate, it appeared suitable to assess the ratio of RNA to core protein more precisely than before.
|
|
|---|
Twenty-one sera with HCV RNA from the diagnostic laboratory of our institute were tested in parallel by the competitive RT-PCR Amplicor Monitor test kit (Roche Diagnostics) and in duplicate (except for two sera) by the LightCycler assay.
All sera were immediately stored at 20°C, aliquoted, and thawed only once before HCV RNA testing and the HCV core antigen assay.
Primers and probes. The primers used were NCR-s (5'-TGC GGA ACC GGT GAG TAC A; positions 193 to 175) and NCR-as (5'-CTT AAG GTT TAG GAT TCG TGC TCA T; positions 24 to 1) (nucleotide positions are relative to the sequence of GenBank accession no. M58335, first codon). The hybridization probes were HCV-NCR-LR (5'-LC Red640-TGC CTG ATA GGG TGC TTG CGA GT-p; positions 52 to 30) and HCV-NCR-FL (5'-GGT CGC GAA AGG CCT TGT GGT A-FL; positions 75 to 54). Primer and probe sequences were selected for optimal conservation between HCV isolates.
RNA extraction and preparation. Viral RNA was extracted from 140 µl of serum or plasma by using the QiaAmp viral RNA kit (catalog no. 52904; Qiagen, Hilden, Germany) according to the manufacturer's instructions. To avoid the addition of salt to the RT-PCR mixture, one step was altered in the standard protocol: instead of elution with 60 µl of the proposed elution buffer, we used 60 µl of RNase-free water. Because the target sequence in the end of the 5' noncoding region (NCR) region of the HCV genome contains stable secondary structures of the internal ribosomal entry site (7, 12), 10 µl of RNA was mixed with 1 µl (10 pmol) of antisense primer, incubated for 1 min at 94°C for breaking secondary structures and 1 min at 56°C for annealing of the primer, and then stored on ice. From this freshly prepared RNA extract, 9 µl was used for the one-tube RT-PCR.
One-tube RT and amplification. The RT-PCR was performed by using the LightCycler RNA amplification kit for tests with hybridization probes (catalog no. 2015145; Roche Diagnostics) with 6.5 mM MgCl2. The hybridization probes were added in unequal molarity with 8 pmol of the detection probe (HCV-NCR-LR) and 4 pmol of the anchor probe (HCV-NCR-FL). Adding 10 pmol each of primer (NCR-s and NCR-as) also results in an asymmetric concentration, since the same amount of primer NCR-as was already added for preincubation of the RNA extract. This results in an increased efficiency of amplification.
The RT-PCR conditions were 12 min at 55°C for RT, 30 s at 95°C for denaturation of the reverse transcriptase, followed by 45 cycles of 3 s at 95°C (slope 20°C/s) and 7 s at 64°C (first annealing temperature) to 54°C (touchdown second annealing temperature), with a decreasing step size of 1°C per cycle, and extension for 14 s at 72°C (slope 2°C/s). After the last cycle, a melting curve analysis was performed from 50 to 90°C. The fit point mode for the LightCycler was used for evaluation.
HCV core antigen. For the measurement of the HCV core antigen, we used a preliminary second-generation HCV core EIA (trak-C; Ortho Clinical Diagnostics, Raritan, N.J.) with an optical density cutoff of 1.5 pg of core antigen/ml. Samples with core antigen values above 150 pg/ml were diluted and measured again.
HCV RNA standard. To calibrate the quantification, a highly HCV-positive plasma sample from a blood donor was tested in parallel to the first international standard, 96/790, for HCV (500,000 IU/ml) (15) and then diluted with HCV-negative plasma to a concentration of 106 IU/ml. The calibration of this secondary standard was validated in an international trial for quantifying the WHO standard 96/790 (15).
|
|
|---|
![]() View larger version (12K): [in a new window] |
FIG. 1. Calibration curve obtained with six dilutions of the secondary standard serum plotted as cycle number at the crossing point versus log international units per milliliter.
|
![]() View larger version (13K): [in a new window] |
FIG. 2. Reproducibility and linearity of 24 real-time PCR runs by using the dilution series made from 24 independent extractions of the reference serum. Standard deviations are indicated by error bars.
|
![]() View larger version (15K): [in a new window] |
FIG. 3. Melting curve analysis of the fluorescence resonance energy transfer signal generated by the binding of the two hybridization probes to the plus strands of the amplicon. Data for five dilutions of genotype 1b standard serum (melting point [Tm] = 68.8°C) and five sera of genotype 2a (Tm = 58.7°C) are shown as the first derivative [d(f2/f1)] versus temperature.
|
The use of specific primers, specific hybridization probes, and touchdown annealing temperature combined with a one-tube system is for the quantification of HCV RNA first described in this study. This combination ascertains a high overall specificity of the procedure. The touch-down protocol also reduces the amplification of undesirable side products. The small number of pipetting steps due to the one-tube RT-PCR and the combined amplification and signal generation within a closed system prevented contaminations. All negative controls remained negative during melting curve analysis as well as during agarose gel electrophoresis (data not shown).
Testing 21 samples in parallel with the routinely used Roche HCV Monitor test confirmed the sensitivity of our in-house RT-PCR (Fig. 4). All 21 samples positive by the Monitor test were also positive by the in-house test. The results shown in Fig. 4 suggest that the Monitor test reaches saturation at 5 x 106 IU/ml. Two samples with that result had >107 IU/ml by the in-house test and were outside the 95% prediction interval of correlation (Fig. 4). The two assays were almost perfectly proportional to each other below the saturation level of the Monitor test (correlation coefficient, 0.9578; regression slope, 1.01), particularly at low concentrations. Adding the values >107 IU/ml to the regression, the correlation coefficient is 0.9397 and the slope 1.092. But the real-time PCR generated, on the average, 1.5-times-lower results. Given a 95% prediction interval of around factor 2.5 for the correlation of the two assays (Fig. 4), this difference is comparatively insignificant. Due to the very good reproducibility of the real-time assay, the relatively large variance of correlation may be due to the competitive Monitor assay, which is in general believed to have a 95% confidence interval of ca. a half log10 step (14).
![]() View larger version (21K): [in a new window] |
FIG. 4. Correlation between the LightCycler real-time and Roche Monitor competitive RT-PCR for 21 serum samples. Linear regression was calculated with real-time HCV RNA values of <107 IU/ml ( ) (r2 = 0.9578) and indicated together with the 95% prediction interval (black and dotted lines, respectively). Theoretically, both assays should give identical values, as shown by the grey line. , values of >107 IU/ml.
|
In the melting curve analysis, all specimens of genotype 2 showed a 10°C lower melting temperature of 58.5 to 60.2°C (Fig. 3) of the hybridization probes due to a conserved C-T exchange at position 72, which is found at the fourth position in the probe HCV-NCR-FL. This lower melting point of the hybridization probe HCV-NCR-FL did not affect the quantification and efficiency of amplification.
The LightCycler method and the HCV core antigen EIA were applied in parallel to 256 serial serum samples from 23 patients undergoing an interferon-ribavirin combination therapy. The sera were from early time points before or within the first 3 days of treatment. One hundred ninety-seven samples were positive by both assays, 4 were only HCV RNA positive, 2 were only HCV core antigen positive, and 51 were negative by both assays. Thus, assuming all results to be truly positive, the sensitivity of the HCV RNA assay was 99.0%, and that of the core assay was 98.0%. The four core-negative samples had between 80 and 940 IU of RNA/ml. The two RNA-negative samples had 2.7 and 3.7 pg of core antigen/ml. Tanaka et al. (18) also reported a sensitivity of 98% for their version of the core assay, but Zanetti et al. (20) found only 82% sensitivity.
The quantitative relation of RNA and core antigen is shown in Fig. 5. From the mean of the RNA/core ratios of the samples positive by both tests, we calculated that 1 pg of total HCV core antigen corresponds on the average to 7,890 (±410 [standard error]) IU of HCV RNA. Using the same HCV core EIA and the Monitor assay, an almost identical ratio of 8,000 IU/pg was found by Bouvier-Alias et al. (2), but the high standard deviation of the Monitor assay for HCV RNA disabled the interpretation of the high variability of the RNA/core ratio. In our study, the correlation between both parameters was rather low, with r2 = 0.744. In contrast, the correlation (r2) of the measured and the true concentrations in the calibration curves was for both assays always >0.99 and mostly >0.999. Zanetti et al. (20) also found a relatively low correlation (r2 = 0.83) between HCV RNA with the Roche Monitor assay and the preliminary version of the trak-C assay.
![]() View larger version (21K): [in a new window] |
FIG. 5. Correlation between HCV RNA quantification by the LightCycler and measurement of HCV core antigen with EIA (trak-C) for 197 serum samples from follow-up with 23 interferon-treated patients. The linear regression (black line) and 95% prediction interval (dotted line) are indicated.
|
Theoretically, HCV, as a member of the Flaviviridae virus family, may contain an icosahedral capsid of T3 or T4 symmetry with 180 or 240 core protein subunits and one RNA genome (6). Assuming 240 subunits, a molecular mass of 19,000 Da for core protein and 1 IU of HCV RNA corresponding to 3 RNA molecules, 1 pg of virus cores ought to contain 130,000 HCV genome molecules. However, the measured ratio never exceeded 20,000 IU or 60,000 genomes per pg of core protein in our study and was on the average ca. 24,000 genomes/pg. Thus, on the average, only 18% of the core protein would be associated with HCV particles containing RNA and 240 core subunits, whereas the majority of the protein would be associated with structures devoid of HCV RNA. Such structures have been proposed by Maillard et al. (9).
Alternatively, particles would contain one genome and ca. 1,000 core subunits on the average. This is very unlikely because the particles are believed to be 50 nm in diameter (6) or less (19), and this size would not accommodate so many subunits.
The excess of core antigen over HCV RNA enhances the clinical sensitivity of the core antigen EIA. Theoretically, at an analytical sensitivity of 1.5 pg/ml, no sample containing <65,000 IU/ml should be detectable by the core EIA. However, 81 core-positive sera from interferon-treated patients contained less RNA, and 12 sera contained <1,000 IU/ml.
The question of whether subviral particles are present in HCV infection is mostly relevant for structural and clinical questions. Our data support the possible existence of RNA-free but core antigen-containing structures, either secreted by the infected cell or generated by in vivo degradation. As in the case of hepatitis B (HBsAg and HBeAg), the excess of viral antigen of HCV could function as a decoy for the immune system. Therefore HCV RNA and HCV core antigen levels in serum are not equivalent or simply stoichiometrically related parameters but could reveal new information about infection status upon treatment follow-up.
In conclusion, we have established a real time quantitative RT-PCR for HCV which is conveniently performed in one tube and uses hybridization probes for increased specificity. The primers used are well conserved in HCV genotypes 1 to 6, thus enabling a quantitative PCR with identical efficiency of all genotypes contained in the WHO reference panel. The comparison with the competitive PCR shows that the larger dynamic range of real-time PCR is required for accurate quantitation without testing expensive dilution series. The comparison with the HCV core EIA shows that the EIA is surprisingly sensitive (98%) in this special interferon-treated group, missing only very few HCV RNA positive samples. However, it appears that levels of HCV core antigen do not strictly correlate to HCV RNA. The factors influencing the ratio of HCV core protein to HCV RNA are the subjects of further studies.
We thank Uli Birk for assistance with the testing of diagnostic sera and W. R. Willems for sera pretested with the Amplicor Monitor.
C.G.S. was supported by a grant of the ENHCV consortium of the European Union.
Present address: DLR Projektträger des BMBF, Bonn, Germany. ![]()
Present address: Department of Virology, Institute for Medical Microbiology, University of Rostock, D-18055 Rostock, Germany. ![]()
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»