JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strålin, K.
Right arrow Articles by Törnqvist, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strålin, K.
Right arrow Articles by Törnqvist, E.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, July 2004, p. 3377, Vol. 42, No. 7
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.7.3377.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

LETTER TO THE EDITOR

Legionella pneumophila Serogroup 1 Antigen Can Be Detected in Sputum Samples by an Immunochromatographic Assay


    LETTER
 Top
 Letter
 Reference
 
The NOW immunochromatographic test (ICT) (Binax, Portland, Maine) for detection of Legionella pneumophila serogroup 1 antigen was recently reported (P. C. Wever, D. W. Notermans, I. I. Tulevski, J. K. M. E. Schattenkerk, and M. D. de Jong, Letter, J. Clin. Microbiol. 41:2265, 2003) to be positive in bronchoalveolar lavage fluid from a patient with Legionnaires' disease. In order to test if the ICT could be used on sputum samples, we collected repeated samples from a 75-year-old man with previous myocardial infarction, who turned out to have legionellosis. Five days after onset of illness, he was admitted with a right-sided community-acquired pneumonia (CAP) and a Fine's score of 120. He was initially treated with cefuroxime, and on day 2 from admission, when he was tested ICT positive in a urine sample, the treatment was switched to ciprofloxacin monotherapy. The patient was intubated and received mechanical ventilation between days 2 and 8 and between days 9 and 13, and the antibiotic treatment was discontinued on day 22. He improved and was discharged from the hospital on day 38. Sputum samples were collected on days 1, 8, 13, and 20, after which he was unable to expectorate sputum. On days 5 and 10, endotracheal secretion samples were taken. Routine bacterial cultures were negative, but the first sputum sample was culture positive for Legionella spp., which was identified as L. pneumophila serogroup 1 at the Legionella reference laboratory, Uppsala University Hospital, Uppsala, Sweden. Legionella culture of the sputum sample from day 8 and of both endotracheal secretion samples was also performed, with negative results. When the four sputum samples and two endotracheal secretion samples were tested with ICT, they all produced positive results, without any manipulation prior to testing. The patient also remained ICT positive in five urine samples taken at the same times as the lower respiratory tract specimens from day 5 to day 20. When two sputum samples, one endotracheal secretion sample, and three urine samples were retested after a period of freezing, all remained ICT positive.

As a pilot control study, ICT was tested on frozen sputum and urine samples from five hospitalized patients with CAP and a median Fine's score of 115 (range, 46 to 191). All samples produced negative results. The patients had well-established CAP causes: i.e., blood and sputum cultures positive for Streptococcus pneumoniae (n = 2), blood and sputum cultures positive for Haemophilus influenzae, complement fixation test and sputum PCR positive for Mycoplasma pneumoniae, and microimmunofluorescence test and sputum PCR positive for Chlamydia pneumoniae.

ICT applied on sputum samples has promising potential for clinical use, as Legionella culture is limited by a low sensitivity (1) and Legionella PCR has been complicated by the risk of intermittent contamination of some commercial DNA extraction kits (A. van der Zee, M. Peeters, C. de Jong, H. Verbakel, J. W. Crielaard, E. C. J. Claas, and K. E. Templeton, Letter, J. Clin. Microbiol. 40:1126, 2002). Because of its speed and ease of performance, ICT can be used for bedside examination. Further studies are needed to investigate the clinical usefulness of the assay applied to sputum samples. As urine excretion of Legionella antigen has been suspected to be delayed (1), it would be interesting to investigate if sputum samples will be ICT positive earlier than urine samples in the course of Legionnaires' disease.

(The present study was part of a prospective study of pneumonia etiology approved by the ethics committee of the Örebro County Council [868-1999].)


    ACKNOWLEDGMENTS
 
The prospective study, of which the present study was a part, is supported by grants from the Research Committee of Örebro County Council and the Örebro University Hospital Research Foundation.


    REFERENCE
 Top
 Letter
 Reference
 

  1. Waterer, G. W., V. S. Baselski, and R. G. Wunderink. 2001. Legionella and community-acquired pneumonia: a review of current diagnostic tests from a clinician's viewpoint. Am. J. Med. 110:41-48.[CrossRef][Medline]
Kristoffer Strålin*
Ingegerd Alriksson
Eva Törnqvist

Departments of Infectious Diseases  and Clinical Microbiology
Örebro University Hospital
SE-70185 Örebro, Sweden

* Phone: 46196023619,Fax: 4619184855,E-mail: kristoffer.stralin{at}orebroll.se


Journal of Clinical Microbiology, July 2004, p. 3377, Vol. 42, No. 7
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.7.3377.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.





This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strålin, K.
Right arrow Articles by Törnqvist, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strålin, K.
Right arrow Articles by Törnqvist, E.


Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS