Journal of Clinical Microbiology, August 2004, p. 3758-3765, Vol. 42, No. 8
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.8.3758-3765.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Institute of Pathology,1 Institute of Gynecology, Alfons,3 Department of First Internal Medicine, Private Medical School, Salzburg,4 Division of Oncology, Department of Internal Medicine, Karl-Franzens University, Graz, Austria2
Received 14 November 2003/ Returned for modification 10 January 2004/ Accepted 14 March 2004
|
|
|---|
= 0.661) and HPV18 (
= 0.781) status as measured by real-time PCR and conventional PCR, indicating similar sensitivities. We recognized an inhibitory effect of formalin fixation and paraffin embedding on the evaluation of real-time PCR quantification. |
|
|---|
For a pathologist, the retention of morphology and the histological context of a tumor is very important. Especially in the case of cervical carcinoma, the phenomenon of koilocytosis indicates an infection with human papillomavirus (HPV) (4) that can only be detected by microscopic analysis of tissue sections. Moreover, episomal and integrated viral DNA can only be differentiated by ISH due to the staining pattern (8). With the use of chromogenic tyramide-signal-amplified ISH (CISH) it is even possible to detect and localize single or very few HPV copies within infected nuclei (15, 36, 49). However, this technique is rather cost-intensive and quite involved for routine applications.
Conventional PCR is held to be the most sensitive detection method available (9, 16, 20, 27, 37, 41). Although this is probably true, it has some limitations, as does ISH, in that it cannot quantify viral load in a prognostic-diagnostic significant manner. This restriction can be circumvented by the use of real-time quantitative PCR. Real-time PCR allows the detection and quantification of products generated during PCR process. The reagents most commonly used for real-time PCR include 5' nuclease assay with TaqMan probes, molecular beacons, and SYBRGreen I intercalating dyes. We used SYBRGreen technology because it is easier to handle in routine applications and to optimize. The use of FFPE specimens for real-time PCR is not yet frequently a standard method in laboratories and therefore is not often reported (28, 29, 33). It is also rarely used for quantification of HPV (46).
HPV is known to be a major risk factor in the development of genito-anal neoplasia (19, 51). Low-risk HPV types (e.g., HPV type 6 [HPV6] and HPV11) are distinguished from intermediate-risk (e.g., HPV31, -33, and -51) and high-risk (e.g., HPV16 and -18) HPV types (3, 32). In particular, high-risk HPV types are involved in almost 100% of the instances of cervical cancer. Cervical squamous cell carcinomas develop from progenitor lesions, so-called cervical intraepithelial neoplasias (CINs; I to III). Viral load of human papillomavirus might be of prognostic-diagnostic significance (21, 31, 45). With increasing amounts of high-risk HPV, the risk for the development of squamous intraepithelial lesions and CINs and further transformation to invasive cervical carcinoma, as well as the severity of cervical disease, is likely to increase (22, 44, 45). Although high-risk HPV is known to be a major risk factor for the development of cervical cancer from CIN, its role in established cervical cancer concerning progression and clinical outcome is still controversial (11, 12, 14, 21, 26, 34, 35, 39). The amount of viral DNA present in the tumor could represent an important aspect for course and strength of disease. Since methods for viral load determination are available and becoming more reliable, that question gains in importance (5, 30, 38).
Ideally, a quantitative assay for viral nucleic acids should possess high sensitivity, specificity, and reproducibility, yield an accurate determination of copy number, and be fast and easy to use in routine work. We compared the applicability, handling, and sensitivity of real-time PCR versus CISH and conventional PCR for the detection of HPV in FFPE cervical cancer tissues.
|
|
|---|
Cervical cancer cell lines (SiHa, HeLa, and CasKi) were obtained from the American Type Culture Collection (Rockville, Md.). They are infected with ascending copy numbers of HPV. SiHa cells contain 1 to 2 copies of HPV16, and CasKi cells contain about 600 copies of HPV16; HeLa cells harbor 40 to 50 copies of HPV18. These cell lines were used for the establishment of an external standard curve for real-time PCR and served as positive controls.
CISH. For the CISH method, the Enzo Diagnostics kit was used with different probe mixtures for HPV6 and -11 (HPV6/11), -16/18, and -31/33/51 in combination with the Dako GenPoint kit. This method allows the detection and localization of single or very few copies of HPV-infected nuclei. The tyramide reporter molecule amplifies the number of the biotin molecules, which enhances the binding of streptavidin-peroxidase complex. Then, 4-µm sections were mounted and baked onto silanized slides at 60°C for 1 h, and the protocol was performed according to the manufacturer's recommendations.
Extraction of DNA from FFPE sections and cultured cells. First, 5 to 20 10-µm sections (dependent on tissue size) were collected in 1.5-ml Eppendorf tubes for DNA isolation. To prevent cross-contamination, each block was cut after thorough cleaning of the microtome with a new blade. DNA extraction was carried out by using the QiaAmp DNA minikit (Qiagen) and the appropriate spin columns according to the manufacturer's protocol. The quality (ratio of 260/280 nm) and quantity (absorbance at 260 nm) of isolated DNA were determined by optical density measurement.
HeLa, CasKi, and SiHa cells were grown for about 5 days in the appropriate medium (HeLa and CasKi cells, Dulbecco modified Eagle medium; SiHa cells, RPMI 1600 [Gibco-BRL, Grand Island, N.Y.]). DNA isolation was performed with the QiaAmp DNA minikit according to the protocol for cultured cells grown in monolayer. An aliquot of the cultured cells was collected before adding proteinase K and fixed in 4% buffered formalin to count the cells in a Bürker-Türk cell counter. The number of copies of viral DNA per microliter was derived from the number of cells estimated to be present in that same volume.
Conventional PCR. HPV detection was made by PCR with DNA from paraffin-embedded cervical cancer tissue. A universal HPV primer pair (termed "consensus primer") and primer pairs specific for the high-risk HPV16 and -18 were used. The frequently used MY09-MY11 consensus primer contains several degenerate nucleotides and is thus a mixture of 24 primers capable of amplifying a 450-bp fragment within the conserved L1 region common to numerous HPV types; it therefore recognizes a wide spectrum of HPV types (18, 20). This primer pair is routinely used in our lab. The primer sets for HPV16 (E6/E7 region; product size, 96 bp) and HPV18 (product size, 115 bp) (1) were as follows: primer set HPV16fwd (accession no. AF469197, bases 389 to 408; 5'-GGTCGGTGGACCGGTCGATG-3') and HPV16rev (accession no. AF469197, bases 465 to 484; 5'-GCAATGTAGGTGTATCTCCA-3) and primer set HPV18fwd (accession no. AY262282, bases 7004 to 7023; 5'-CCTTGG ACGTAAATTTTTGG-3') and HPV18rev (accession no. AY262282, bases 7100 to 7119; 5'-CACGCACACGCTTGGCAGGT-3'). Amplification reactions contained a final volume of 50 µl and were performed with 1x Taq PCR master mix kit (Qiagen), 0.5 µM concentrations of each primer, and either 5 µl of nondiluted or 5 µl of 1/10-diluted DNA samples. PCR was performed by using the following cycling conditions: first, 3 min at 95°C; then 40 cycles of 95°C for 15 s, 59°C (for HPV18) or 60°C (for HPV16) for 20 s, and 72°C for 25 s; with a final elongation of 7 min at 72°C. The cycling protocol for MY09/MY11 was as follows: 3 min 95°C; followed by 35 cycles of 95°C for 30 s, 55°C for 30 s, and 72°C for 90 s; with a final elongation of 7 min at 72°C. The quality of sample DNA was validated by amplification of a 286-bp fragment of the housekeeping gene ß-globin. 5 µl of each PCR product was electrophoresed in a 1.5% agarose gel (Agarose Multi-Purpose; Roche). Images were recorded by using the Geldoc 2000-System (Bio-Rad).
Real-time PCR. The I-Cycler instrument (Bio-Rad) permits the simultaneous amplification and quantification of the PCR-product at each cycle. We used the SYBRGreen system for the determination of absolute amounts of viral DNA by standardizing with DNA from cultured cells containing known copy numbers of HPV, which were included in each run in duplicates in the form of a series consisting of five dilutions with amounts ranging from 102 to 106 copies of HPV to create an external standard curve. The final standard regression straight line was made up of the breakpoint signals of both series. A master mix with the SYBRGreen PCR core reagents (PE Biosystems) was optimized for the I-Cycler instrument and contained the following: 5 µl of each probe (diluted 1/100 in H2O), respectively; 5 µl of the cell line-DNA dilution; 1x SYBRGreen buffer; 5 mM MgCl2; a 0.25 mM concentration of each deoxynucleoside triphosphate; a 0.5 µM concentration of each primer; and 1.25 U of AmpliTaq Gold polymerase in a final volume of 50 µl. The reaction mix and samples were loaded into a 96-well plate (Bio-Rad). The thermal cycler conditions were as follows: 40 cycles of 95°C for 12 min, 95°C for 15 s, 59°C (for HPV18) or 60°C (for HPV16) for 20 s, and 72°C for 25 s. A calibration with an external calibration plate containing 50 µl of 40 µM calibration dye (Bio-Rad)/well was performed prior to each run. The absolute viral copy number in the unknown samples was calculated from the Ct value by using the I-Cycler software. Each sample was measured twice, and the average copy number, rounded to whole decimal powers, was used in further calculations and statistics. Normalization was carried out by extrapolating the concentration of copy numbers present in the samples on the basis of known amounts (determined by optical density measurement) applied in real-time PCR.
Specificity and sensitivity of real-time PCR.
Melting curve analysis was performed after PCR amplification to prove product specificity in real-time PCR. Starting at 60°C, the temperature in the thermal chamber was raised to 95°C at a transition rate of 1°C/s. PCR products were considered to be specific if they had deviations of
1°C from their expected melting temperatures. Deviations of >1°C indicated that the starting quantity was too small and that the product has been contaminated by unspecific primer-dimer melting signals, thus limiting the instrument's ability for accurate PCR product specification.
Differences in sensitivity between a gel-free (real-time PCR) and a gel-required (conventional PCR) system should become obvious in comparisons of the sensitivity of product visualization. Therefore, we used starting amounts of HPV16 ranging from 101 to 106 copies of HPV DNA from Caski cells. One dilution series was performed in DNA from HPV-negative paraffin-embedded cervical cancer material, and another one was performed in non-paraffin-embedded DNA from HeLa cells. Both samples contained approximately the same amounts of "background DNA" (for the paraffin-embedded sample, 66 ng of DNA/µl; for the HeLa cells, 80 ng of DNA/µl).
The influence of paraffin embedding on the efficacy of amplification and real-time PCR evaluation was tested as follows. The same amount of HPV16 target DNA (104 copies [from CasKi cells]) was added to dilution series made from different HPV-negative paraffin samples and three non-paraffin-embedded samples (HeLa cells). The DNA concentration of the six paraffin-embedded samples ranged from 62.5 to 86 ng/µl, and the DNA concentrations of the HeLa cells were 72, 80, and 91.3 ng/µl. This assay was used to compare nondiluted and diluted paraffin-embedded DNA samples with each other and with DNA from fresh cell material (HeLa cells). We used three 10-fold dilutions to determine at which point of the PCR the inhibiting effects of paraffin (if any) disappeared. Again, this assay was performed by using both real-time PCR and conventional PCR. Visualization of conventional PCR on gel was compared to the results obtained from I-Cycler instrument.
Controls. For ISH, HPV-positive cases for HPV6/11, -16/18, and -31/33/51 and FFPE cell lines were used. DNA isolated from the cell lines mentioned above (SiHa and CaSki cells for HPV16 and HeLa cells for HPV18) were used as positive controls for conventional PCR and real-time PCR. In conventional PCR and real-time PCR, a negative control containing reagents only was used, and in ISH HPV-negative cases served as negative controls.
Statistical analysis. Statistical analyses were performed by using the SPSS statistical package (SPSS, Inc., Chicago, Ill.). Kappa statistics were used to assess concordance between pairwise grouped methods. The kappa statistics evaluates the level of agreement adjusted for agreement expected to occur by chance alone. Kappa statistics less than 0.4 represents fair too poor agreement, values of 0.4 to 0.8 represents moderate to good agreement, and values of more than 0.8 represent excellent agreement. Survival analysis was performed by Kaplan-Meyer-statistics (log-rank test).
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Incidence of HPV-positive cases as determined by CISH, conventional PCR, and real-time PCR
|
|
View this table: [in a new window] |
TABLE 2. Quantification of HPV by real-time PCR
|
= 0.313, 95% confidence interval [CI] = 0.134 to 0.492 [indicating a concordance of 66.2%]).
There was also a fair concordance between the HPV16/18 status as measured by ISH and PCR (
= 0.275, 95% CI = 0.124 to 0.425). Of 63 ISH-positive cases, 58 (92.1%) were also found to be positive by conventional type-specific PCR. Of 80 ISH-negative cases, only 30 (37.5%) were determined to be negative with conventional type-specific PCR.
A fair concordance was also found between ISH and real-time PCR for HPV16/18 status (
= 0.259, 95% CI = 0.111 to 0.407), with a similar trend: of 64 HPV16/18-positive cases as determined by ISH, 63 (95.3%) were also found to be positive by real-time PCR, but of 82 ISH-negative cases, only 27 (32.9%) were found to be negative by real-time PCR.
(ii) Real-time PCR versus conventional PCR.
We found a substantial degree of agreement between the HPV16 status revealed by real-time PCR and that determined by conventional PCR (
= 0.661, 95% CI = 0.539 to 0.783). Of 97 HPV16-positive cases as determined by real-time PCR, 87 (89.7%) were also found to be positive by conventional PCR. Of the 61 HPV16-negative samples as determined by real-time PCR, 46 (75.4%) were also found to be negative by conventional PCR.
As in the case of HPV16, there was also considerable concordance (
= 0.781, 95% CI = 0.662 to 0.900) between HPV18 status measured by real-time PCR and that measured by conventional PCR. Of 34 HPV18-positive results determined by real-time PCR, 29 (85.3%) were also found to be positive by conventional PCR, and of 127 HPV18-negative results determined by real-time PCR, 120 (94.5%) were also found to be negative by conventional PCR.
Influence of formalin fixation and paraffin embedding on real-time PCR and optimization of SYBRGreen assay conditions. When DNA from paraffin-embedded material was used in real-time PCR, the I-Cycler instrument displayed strongly increased relative fluorescence units right from the start up, which was in contrast to that of the control (non-paraffin-embedded material). This resulted in an underestimation of the starting target DNA quantity after baseline subtraction. This can be seen in the results of the test assay, which show that a more accurate absolute quantitative measurement was reached by a dilution of the paraffin-embedded samples (Fig. 1). In paraffin-embedded samples, viral DNA was measured in proportion at higher dilutions of paraffin-embedded DNA, approaching the actual amount of HPV16 present in the samples. Using nondiluted paraffin samples, there was again a clear underestimation of the actual amount of HPV16 DNA. This effect was not seen with DNA from HeLa cells. A 1 in 100 dilution was used for the subsequent real-time PCR assays because at this dilution nonspecific interference was minimal.
![]() View larger version (60K): [in a new window] |
FIG. 1. Positive effect of dilution of FFPE tissue on copy number determination. A, actual amount (copy numbers) of HPV in each sample; B to G, paraffin-embedded samples; I and J, non-paraffin-embedded samples (HeLa cells); n.d., nondiluted samples; 1:10 to 1:1,000, dilution series of samples.
|
Sensitivity of real-time PCR.
We used a dilution series of HPV16 from 101 to 106 copies, diluted with either DNA from paraffin-embedded tissue or cultured cells. There was slight variation in the detection limits at 100 and l01 copies of HPV16 between conventional PCR and real-time PCR (Fig. 2). This result was probably due to slight handling variations during gel preparation, to pipetting variations, or to the use of different cycling instruments. When we compared the results with paraffin-embedded material versus non-paraffin-embedded material obtained by real-time PCR on gels, no difference in sensitivity was seen (Fig. 2C and D). A difference in the detection limit between paraffin-embedded and non-paraffin-embedded material was evident when we evaluated the results from the I-Cycler software. The results of HPV16 diluted in paraffin-embedded DNA were continually underestimated, and at a starting amount of
10 copies a dramatic reduction in detection was apparent. Only 7% of the actual amount was measured when we used 1 or 10 copies of HPV16 diluted in paraffin-embedded DNA, and a starting amount of 101 copies gave a negative value. The melting temperature was specific for all sample dilutions (83°C), except when 101 copies were diluted in HeLa cell DNA, in which case the melting temperature was reduced to 82°C. We interpret this as being the result of the formation of primer-dimers, which also explains the overestimation of copy number.
![]() View larger version (94K): [in a new window] |
FIG. 2. Dilution series of HPV16 (106 to 101 copies). Comparison of sensitivity between paraffin- and non-paraffin-embedded material performed by conventional PCR and real-time PCR visualized on gel. Rows: A, conventional PCR, paraffin-embedded material (DNA from archival HPV-negative cervical cancer tissue sample); B, conventional PCR, non-paraffin-embedded material (DNA from HeLa-cells); C, real-time PCR, paraffin-embedded material (DNA from archival HPV-negative cervical cancer tissue sample); D, real-time PCR, non-paraffin-embedded material (DNA from HeLa cells).
|
|
View this table: [in a new window] |
TABLE 3. Incidence of HPV-positive cases as determined by ISH, conventional PCR, and real-time PCR
|
Patients in tumor stage I with lower viral load of HPV16 (up to 1,000 copies/ng DNA) showed significantly better survival than HPV16-negative patients (P = 0.037). This tendency was also seen in the subgroup of patients without parametrial (P = 0.094), vaginal (P = 0.084), and parametrial lymph node (P = 0.098) infiltration.
Patients with a high viral load of HPV16 (>1,000 copies/ng) DNA tended to have a better prognosis than HPV-negative patients. This was statistically not significant, but in the subgroup of patients with lymphatic space invasion (P = 0.086) and lymph node infiltration (P = 0.063), this trend was maintained.
|
|
|---|
Our findings indicate a higher sensitivity of both real-time PCR and conventional PCR for the detection of HPV16/18 compared to CISH. We found a considerable concordance between HPV16 and -18 status measured by real-time PCR and versus that determined by conventional PCR. We recognized an inhibitory effect of formalin fixation and paraffin embedding on real-time PCR, resulting in underestimation of the viral copy number.
When we compared CISH with PCR, we found that almost all of the HPV16/18-positive cases identified by ISH were also positive by both PCR and real-time PCR, but only a few of the HPV16/18 ISH-negative cases were also found to be negative by PCR and real-time PCR. These findings indicate a greater sensitivity of HPV16/18 PCR compared to CISH for HPV16/18.
From the cases found to be positive by ISH and negative by consensus PCR, some conclusions can be drawn. For example, the fact that some PCR-negative tissues were strongly positive by ISH indicates that the problem of consensus PCR negativity was not due to low sensitivity. This is most likely due to the length of the template of the consensus primer pair MY09/MY11, which may be fragmented as a consequence of formalin fixation and paraffin embedding (13), which makes it difficult to amplify sequences longer than 200 bp (24). The type-specific primer pairs for HPV16 and -18 amplify products by 96 and 115 bp, respectively, thus explaining the higher prevalence of positive cases (74.1%). These results agree with those of Baay et al. (1), whose primers in HPV16 and -18 were used for the present study. Another reason for the different detection rates could be due to a more efficient amplification with the type-specific primers as a result of diluting the template 1 in 10. This was done due to a paucity of material and because template dilution had a positive effect on the efficiency of previously performed real-time PCR.
The reason for ISH-negative cases that are determined to be positive by consensus PCR could be the specificity. The MY09-MY11 primer pair detects more than 25 different types of human papillomaviruses (20), whereas the ISH hybridization reaction has only probes for seven types of HPV. Another aspect to be considered is that the presence of the virus may not be homogeneously distributed throughout the tissue block and the viral DNA may not be present in equal amounts in the sections processed for ISH and PCR. Nevertheless, when we compared the detection rates of the different methods, consensus PCR detected far fewer HPV-positive cases (37.3%). It has been reported that the use of the MY/GP-nested PCR significantly increases the positivity rate of HPV DNA detection and should be used for samples with a low viral load of HPV (10, 20).
The detection rate with MY09/MY11 was lower compared to those of some other studies (2, 20, 48). This could be due to the fact that most experiments were performed with non-paraffin-embedded material. The lower incidence of HPV-positive cases compared to other studies could also be due to the well-known problem of long-term storage of paraffin-embedded tissue and its influence on DNA quality. Thus, we also did an analysis of positivity by time. The "newer" cases were significantly more often HPV positive than the "older" cases. This finding again reflects the problems associated with the archiving of FFPE tissue.
Other studies have reported essentially the same frequency of HPV-positive cases in archival tissue, and Baay et al. reported that the use of one general primer pair in paraffin-embedded tissue grossly underestimates the prevalence of HPV in the studied population (1, 37, 46).
Upon comparing conventional PCR and real-time PCR, we found a considerable concordance between HPV type-specific (HPV16 and -18) PCRs. The prevalence for high-risk HPV infections detected by these two methods also coincides with those reported in other studies (1, 21, 37, 46). Nevertheless, 37 discrepant results between type-specific conventional PCR and real-time PCR indicates problems with intersystem variation or possibly reporting of false-negative cases by real-time PCR due to deviations in melting temperatures or reporting of false-positive cases by real-time PCR due to unspecific signals. SYBRGreen has the disadvantage of binding double-stranded DNA of any sequence, thus making accurate product determination more difficult. A problem with discerning specific from unspecific peaks in the melting curves was also reported by Szuhai et al. (46). The use of real-time PCR methods based on specific probes (TaqMan probes) might overcome the problem of nonspecificity and thus permit more accurate quantification.
The higher false-negative rate obtained by real-time PCR for HPV16/18 (17.1%) compared to that obtained by conventional PCR for HPV16/18 (9.8%) could reflect the overdilution of several samples. This may have been avoided by repeating the real-time PCR procedure with lower sample dilutions.
Whereas real-time PCR works well with fresh samples, additional problems are encountered in studies with archival tissues. Archival tissue contributes to the complexity of the assay because of the need to dilute the samples to reduce nonspecific paraffin interference that results in a reduction in assay sensitivity. Another aspect to be considered is that PCR-based assays in general suffer from dilution artifacts due to variations in tumor cell content within the given specimen (43). In terms of real-time PCR, an improvement in quantitative assays can be attained by using microdissected tumor material.
Real-time PCR is becoming more and more available due to its possible application for time-saving high-throughput analysis. However, it is still a very expensive test. In particular, the use of this technology in FFPE specimens requires dilution of the extracted DNA by 1:10 to 1:1,000 (Fig. 2), suggesting that every specimen needs to be tested three times (at dilutions 1:10, 1:100, and 1:1000), multiplying the cost. Adding to the "teething problem" of this technology in FFPE specimens is the difficulty in interpreting certain curves because of nonspecific amplifications and the eventual need to run a gel to resolve the problem. The inability to type HPV, rather than having to run even more reactions, and the need to microdissect tumor tissue to perform real time-PCR also add to the cost.
With respect to the clinical relevance of HPV viral load, our findings indicate that HPV16-positive patients with stage I carcinoma had a significantly better prognosis than HPV-negative patients. In several other studies a similar trend has been observed. Riou et al. found that stage I cervical cancer patients with no detectable HPV DNA showed a higher risk of overall relapse and of distant metastases than comparable HPV-positive patients (39). Higgins et al. also reported that HPV-negative carcinomas were associated with elevated mortality (17). In the study of Ikenberg et al., patients with HPV-negative tumors tended to have a higher risk of death (21). Compared to other studies (44, 45) we did not find a statistically significant increase of HPV viral load with increasing severity of disease. However, in contrast to these studies we did not compare different stages of CINs but different stages of invasive carcinomas.
In performing further subgroup analysis, we found out that patients with a lower viral load of HPV16 in early stage carcinoma had a significantly better survival rate than HPV16-negative patients. We suppose that an infection with HPV16 in early stage cervical carcinoma may favor prognosis due to an altered immune status shifted from a silent to an active status. Tumor cells are well known for their ability to escape from immune surveillance by inducing an immunosuppressed state. Thus, any infection could be helpful and supportive for activating the immune system. It is even suggested that an infection with HPV benefits the prognosis of cancer patients due to an activated immune status (31).
In the subgroup of women with a higher-stage carcinoma with lymph node infiltration and lymphatic space invasion, a high viral load of HPV16 tended to favor prognosis compared to HPV16-negative patients. However, poorly differentiated tumor cells show an extremely altered metabolism, including loss of cell cycle control mechanisms, with p53 as an often mutated tumor suppressor gene. In both HPV-positive and HPV-negative tumors, there is loss of function of wild-type p53in the former because the protein product of the viral E6 gene complexes with that of the p53 gene, leading to its inactivation, and in the latter because the protein itself is altered (23). Ikenberg et al. also found a weak trend for better survival in patients with a higher copy number but independent of the FIGO stage (21). The fact that lower viral load of HPV16 in higher-stage carcinoma is associated with a poorer outcome compared to higher viral load suggests that patients with lower viral load have more "potent" HPV E6/E7 proteins or other oncogenic factors. This might also explain the observation that high-risk HPVs of all types are able to induce malignant transformation even when present at low levels (50).
However, in many cases of CIN I, the cell is cured of the virus and reverts to a morphologically normal state. Thus, the immune system seems to play an important role in viral clearance, regression of dysplasia, and tumor development and progression in general; maybe it is even the decisive factor, if a HPV infection appears in a latent form without any consequences for the organism or if cervical cancer can develop. It is possible that some of the HPV-negative tumors could represent a form of carcinoma in which HPV has already been cleared and the immune status has returned to a dormant state. However, the absence of HPV in some tumors could also indicate that (i) they originated through different oncogenic mechanisms and that they may represent a biologically distinct subset of tumors that carry a poorer prognosis (39) or (ii) that there may be some "nastier" HPV types that were not detected, causing the poor outcome.
In summary, we observed a greater sensitivity of both real-time PCR and conventional PCR compared to CISH. However, there are still some problems concerning performance and evaluation of real-time PCR with FFPE material. It appears that cervical cancer patients can be divided into groups differing in their clinical outcome: an HPV16-negative subgroup revealing a poor prognosis and, in contrast, a lower-stage subgroup with a lower viral load and a higher-stage subgroup with a higher viral load, both showing a better survival. These findings are crucial in order to offer each patient an individualized therapy, and it highlights the importance of quantifying viral load, thus emphasizing the necessity of real-time PCR.
|
|
|---|