Previous Article | Next Article ![]()
Journal of Clinical Microbiology, August 2004, p. 3809-3812, Vol. 42, No. 8
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.8.3809-3812.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Department of Medicine, Monash University,1 Infectious Diseases Unit, The Alfred Hospital, Melbourne,4 Victorian Infectious Diseases Reference Laboratory, North Melbourne, Victoria, Australia,2 Department of Medicine, The University of Texas Medical Branch at Galveston, Galveston, Texas3
Received 10 November 2003/ Returned for modification 15 December 2003/ Accepted 26 January 2004
|
|
|---|
|
|
|---|
Mutations leading to lamivudine resistance are generally detected by conventional DNA sequencing after PCR amplification of a selected portion of the viral polymerase gene. The advantage of sequencing includes obtaining information over a span of several nucleotides. However, sequencing is expensive and laborious and has a low level of sensitivity for minority quasispecies, usually only detecting to a level of 20% of the total virus population (8). Other molecular techniques developed to detect the changes associated with lamivudine resistance include restriction fragment length polymorphism, a 5' nuclease assay, a real-time PCR assay using the LightCycler (4, 16), and line probe assay technology (15) (INNO-LiPA HBV DR; Innogenetics, Ghent, Belgium). Using the principle of primer selection, we have developed a quantitative sensitive real-time PCR assay able to detect minority drug-resistant quasispecies at a level of 1 in 1,000. This assay is useful in the early detection of drug resistance and will assist in the study of viral fitness in vivo.
Serum samples were collected from 38 individuals chronically infected with HBV and were either naïve to antiviral therapy or had commenced treatment with lamivudine (n = 21). A total of 75 samples were analyzed, including 38 samples from individuals naïve to lamivudine and 37 samples from individuals on lamivudine.
HBV DNA was extracted from 200 µl of serum by using the QIAamp DNA Mini kit (QIAGEN, Chatsworth, Calif.). Amplification of the HBV polymerase gene has been described previously (5). The INNO-LiPA HBV DR (Innogenetics) testing was performed in accordance with the methods previously published (15). HBV viral load was determined by using real-time PCR as previously described (10).
Discrimination between the wild type and two mutants (rtM204I and rtM204V) was possible by using primers in which the relevant base pair mutation was at or near the terminal 3' base of the primer. A primer-template mismatch at the 3' terminus significantly compromises polymerase efficiency and allows for discrimination between mutants and the wild type even with a single base pair mismatch (9). The efficiency of discrimination by the primer between wild-type and mutant templates is dependent on the specific 3'-terminal base, with maximal reduction of PCR product yield of 100-fold with a A:G, G:A, or C:C mismatch (9).
We designed a common forward primer to a highly conserved sequence within the polymerase open reading frame encoding the C domain of the viral enzyme (RM1, 5'-CACCTGTATTCCCATCCCAT-3') and different reverse linear primers that would allow selective amplification of YVDD (rtM204V), YIDD (rtM204I), and YMDD (wild type) quasispecies (Fig. 1). The amplicon was detected and quantified by using real-time PCR and a molecular beacon (5'-FAM-GGTCCCATTTGTTCAGTGGTTCGTAGGGCTTTGGGACC-DABCYL-3') that annealed to a highly conserved region between the forward and reverse primers. The total viral load was quantified by using a separate PCR with primers and beacon in the precore region (10). Real-time PCR was performed with conditions identical to those previously described (10).
![]() View larger version (19K): [in a new window] |
FIG. 1. Location and sequence of the common forward primer (RM1), common beacon, and specific reverse primers. The target sequence of each mutation is shown.
|
As expected, nonspecific priming to the alternate template (i.e., mutant primers to wild-type template and vice versa) was observed. The degree of cross-priming was first quantified by using a dilution series of template ranging from 108 to 102 copies, and PCR was performed with the mismatched primers (Fig. 2). In most cases, nonspecific priming occurred when the mismatched target was present at >106 copies per PCR. The calculated copy number (of the mismatched target) was at least 4 logs less than the actual copy number present, representing a trivial degree of cross-priming. Mixing experiments were then performed over a 4-log range (wild-type and mutant species were mixed, with concentrations ranging from 102 to 106 copies per PCR; Fig. 3). The actual and calculated copy numbers were identical for the wild-type and mutant templates. The intra-assay variability of each assay was similar to that of the precore quantitative assay (11) and was calculated to be 0.3 log (data not shown).
![]() View larger version (15K): [in a new window] |
FIG. 2. Dilutions of known concentrations of plasmids containing the wild-type (Wt, open squares) or rtM204V and rtM204I mutations (closed diamonds and circles, respectively) were tested with primer sets designed to detect the rtM204V and rtM204I mutations. The actual copy number per PCR is demonstrated on the x axis. The calculated copy number per PCR is shown on the y axis. (a) M204V primers accurately quantify the M204V template. When the M204V primers are used to detect the wild-type template, a false-positive signal is detected when the concentration of the wild-type template is >106 copies; however, the calculated value (or false-positive detection) is reduced to 100 copies. (b) The discrimination between the wild type and mutants is less stringent for the wild type when the M204I primers are used, but the reduction in signal remains at least 4 logs.
|
![]() View larger version (23K): [in a new window] |
FIG. 3. Mixing experiments of mutant (M204V) and wild-type DNA were performed and analyzed by using primers containing the wild-type or mutant sequence. Discriminatory real-time PCR accurately quantified wild-type and mutant input DNA over a 4-log range independent of whether 106 (upper panels), 104 (middle panels), or 102 (lower panels) copies of mutant (left panels) or wild type (right panels) were added. Both the wild type (diamonds) and mutants (crosses) were accurately detected over a 4-log range regardless of their input ratio.
|
|
View this table: [in a new window] |
TABLE 1. Comparison of results obtained by DNA sequencing with those obtained by discriminatory real-time PCR
|
The remaining 12 samples having a discordant result were all identified by sequencing as rtM204I, and in each case the viral isolate contained the sequence ATT. The primer used to detect rtM204I (primer RM5) was designed to detect sequence ATC. Given that stringency of primer binding is most efficient when there is complementarity at the 3' end of the primer, we presume that primer RM5 was inefficient in binding to mutant virus containing ATT. Therefore, for detection of rtM204I variants, a mix of primers specific for both the G/C and the G/T substitution were subsequently used.
Three commonly described sequences can code for rtM204I: ATC, ATT, and ATA. The most common sequence coding for rtM204I in all HBV genotypes is ATT. We designed primers that specifically recognized each of these three sequences (primers RM5, RM6, and RM7, respectively). Data for cross-priming of RM5 to wild-type template has been shown in Fig. 2. RM6 behaved in a fashion similar to that of RM5, with minimal cross-priming to the wild type. The specificity of RM7 for the wild type (i.e., the mismatched template) was 1 log less than that of RM5 and RM6. Due to this lack of specificity, RM7 was not used in the primer mix. When the sensitivity of detection of RM5 and RM6 was evaluated to detect the nonmatched mutant quasispecies, we determined that RM5 detected ATC only (i.e., the complementary sequence) and did not detect ATT or ATA. RM6, however, was able to prime to ATA as well as the complementary sequence ATT. Therefore, the combination of RM5 and RM6 will reliably detect the three major mutants that code for rtM204I.
A further four isolates containing the ATT variant of rtM204I (three specimens contained only rtM204I while one contained a mixture of rtM204 and M204I, as determined by sequencing) were studied by using the rtM204I primer mix. There was concordance between sequencing and real-time PCR for the rtM204-M204I mixture and one of the rtM204I mutants. For the other two rtM204I mutants, the dominant quasispecies detected by real-time PCR was rtM204I (but in a mixture with the wild type).
Five individuals were monitored over time following the introduction of lamivudine in order to determine the relative kinetics of wild-type and drug-resistant quasispecies by using discriminatory real-time PCR, sequencing, and LiPA (Fig. 4). In all but one case discriminatory real-time PCR detected the drug-resistant species at the same time it was detected by LiPA.
![]() View larger version (25K): [in a new window] |
FIG. 4. Longitudinal study of HBV viral load and quasispecies analysis following introduction of lamivudine (shown on the x axis in months). Total HBV viral load (dashed lines), M204V (closed squares), and the wild type at M204 (open squares) were quantified over time. Results from LiPA and PCR sequencing are shown above each graph as M (wild type), V (M204V), I (M204I), or ND (not done).
|
The most common reason for discrepant results between sequencing and our discriminatory real-time PCR assay could be attributed to polymorphisms in the YMDD region. By the inclusion of two primers for detection of the YIDD change, we were able to detect all three variants (ATC, ATT, and ATA). For the YVDD mutant, the primer only detected GTG and not the minor infrequent double mutation (GTT). The GTT mutation occurs at a significantly lower frequency, accounting for approximately 1% of YVDD variants (A. Bartholomeusz and L. Yuen, personal communication). We designed primers that also detected these YVDD quasispecies, but significant nonspecific cross-priming occurred in the wild type, making this approach impractical. Given the infrequent prevalence of these mutations, we did not think that the ability to detect only the GTG variant would compromise the clinical utility of the assay.
The discriminatory real-time PCR assay for lamivudine-resistant mutations could potentially be applied to the clinical setting to monitor HBV-infected patients receiving antiviral therapy while simultaneously measuring HBV viral load. As newer antiviral agents are introduced, such as adefovir and tenofovir, and as resistance is encountered (2), the application of these assays could allow for an earlier change in antiviral therapy before viral breakthrough occurs.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»