This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Foglia, G.
Right arrow Articles by Michael, N. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Foglia, G.
Right arrow Articles by Michael, N. L.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, August 2004, p. 3850-3852, Vol. 42, No. 8
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.8.3850-3852.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

Use of Rapid and Conventional Testing Technologies for Human Immunodeficiency Virus Type 1 Serologic Screening in a Rural Kenyan Reference Laboratory

Ginamarie Foglia,1 G. Donald Royster IV,2 K. Monique Wasunna,3 Rukia Kibaya,3 Jennifer A. Malia,4 Eva K. Calero,4 Warren Sateren,4 Philip O. Renzullo,4 Merlin L. Robb,4 Deborah L. Birx,4 and Nelson L. Michael4*

U.S. Army Medical Research Unit—Kenya,1 Kenya Medical Research Institute, Nairobi, Kenya,3 Uniformed Services University School of Medicine, Bethesda, Maryland 20814,2 U.S. Military HIV Research Program, Division of Retrovirology, Walter Reed Army Institute of Research, Rockville, Maryland 208504

Received 6 January 2004/ Returned for modification 10 April 2004/ Accepted 4 May 2004


arrow
ABSTRACT
 
We report a prospective comparison of human immunodeficiency virus type 1 testing by enzyme immunoassay and Western blot with four rapid tests of 486 subjects performed in rural Kenya. Rapid test sensitivity was 100%. Specificity ranged from 99.1 to 100%. Combined use of two Food and Drug Administration-approved rapid tests yielded a single false-positive result.


arrow
TEXT
 
Point-of-care diagnosis of human immunodeficiency virus type 1 (HIV-1) infection is critical to increasing serologic awareness and to reduce risk behaviors associated with HIV-1 transmission (7). Rapid HIV-1 tests yield results during a single visit, providing a considerable benefit in settings where return visit adherence is low (6, 22). Rapid HIV-1 tests have been widely used outside the United States (1-4, 8-11, 13, 15, 18, 20, 21, 23). However, studies documenting the direct comparison of reference enzyme immunoassay (EIA) and Western blot HIV-1 testing to rapid HIV-1 testing, in which both modalities were prospectively executed with fresh specimens by the same staff in field laboratories, are few and not recent (19). We report such a study with modern rapid tests in rural Kenya.

Study subjects. Blood samples were obtained from subjects enrolled in the U.S. Military HIV Research Program's HIV and Malaria Cohort Study in Kericho, Kenya. This study of 2,803 adult residents of a Kenyan highland tea plantation is gathering data on HIV incidence and infection risk factors. Volunteers, enrolled in the summer of 2003, return semiannually for physical examination and HIV-1 testing. The study was approved by the appropriate human use review boards.

HIV-1 serologic testing. Serologic point-prevalence HIV-1 testing was performed on-site at the Walter Reed Project laboratory by Kenyan staff. Fresh venous blood specimens from 486 study subjects who were enrolled during July and August 2003 were subjected to initial EIA screening with the Genetic Systems rLAV test (Bio-Rad Laboratories, Redmond, Wash.). If the initial EIA was nonreactive, the sample was interpreted as HIV-1 antibody negative. If the initial EIA result was reactive, the sample progressed to testing with the Vironostika HIV-1 Microelisa system (Organon Teknika, Durham, N.C.), using duplicate serum aliquots. Repeatedly reactive samples (at least two of three reactive EIA reactions) were subjected to confirmatory testing with the Genetic Systems HIV-1 Western blot (Bio-Rad Laboratories). Both EIA and the Western blot tests are approved by the U.S. Food and Drug Administration (FDA).

Rapid serologic testing was performed at the Walter Reed Project laboratory on the same day as phlebotomy. Anticoagulated whole blood (EDTA) was used for the OraQuick HIV-1 (OraSure Technologies, Inc., Bethlehem, Pa.), UniGold Recombigen HIV (Trinity Biotech, Inc., Wicklow, Ireland), and Determine HIV-1/2 (Abbott Laboratories, Inc., Abbott Park, Ill.) tests. Serum was used for the Reveal HIV-1 test (MedMira, Inc., Halifax, Nova Scotia, Canada). The OraQuick HIV-1 and Reveal HIV-1 tests were approved by the FDA for serologic detection of HIV-1 antibody at the time of testing, while the UniGold Recombigen HIV test was approved 23 December 2003.

HIV-1 nucleic acid testing. Frozen plasma samples shipped to Walter Reed Army Institute of Research were subjected to the HIV-1 Monitor test, version 1.5 (Roche Diagnostics, Indianapolis, Ind.), in the standard mode from subjects whose sera tested reactive by rapid test devices but nonreactive by rLAV EIA.

Statistical methodology. Sensitivity, specificity, and predictive values were calculated as described previously (5). Fisher's exact test was performed with StatView, version 5.0.

Initial EIA testing was nonreactive on 424 specimens and reactive on 62 specimens. Subjects whose specimens were nonreactive by initial EIA were defined as HIV-1 seronegative (true negative). All 62 initial EIA reactive specimens were concordantly reactive with both the Vironostika HIV-1 EIA and Genetic Systems HIV-1 Western blot. These subjects were defined as HIV-1 seropositive (true positive), yielding an HIV-1 seroprevalence of 12.8% (95% confidence intervals [CI], 9.8 to 15.7%).

All 62 true-positive specimens were reactive by the OraQuick HIV-1, Determine HIV-1/2, and UniGold Recombigen HIV rapid tests (Table 1). Sixty-one of these specimens were reactive by the Reveal HIV-1 test (remaining sample not tested).


View this table:
[in this window]
[in a new window]
 
TABLE 1. Test results and operating characteristics of four rapid HIV-1 tests

Seven specimens nonreactive by reference serology were reactive in eight rapid test evaluations (false positive) (Table 1). False-reactive results were noted with OraQuick HIV-1 (three specimens), Determine HIV-1/2 (four specimens), and Reveal HIV-1 (one specimen) testing. One specimen was reactive with both the OraQuick HIV-1 and Reveal HIV-1 test. No false-reactive results were observed with the UniGold HIV test. Quantitative HIV-1 RNA testing was below the level of detection on all seven specimens.

Rapid test sensitivity was 100%, with the 95% CI ranging from 92.6 to 100% (Table 1). Specificity ranged from 99.1% (Determine HIV-1/2) to 100% (UniGold HIV), with the 95% CI ranging from 97.4 to 100%. The positive predictive value (PPV) ranged from 93.9 (Determine HIV-1/2) to 100% (UniGold HIV). The lower bounds of the 95% CI for PPV for the Determine HIV-1/2 and UniGold HIV tests were 84.4 and 92.7%, respectively. The negative predictive value for all tests was 100%, with the lower bound of the 95% CI calculated as 98.9%.

Rapid test positive and negative predictive values are given with the observed prevalence (12.8%) and three hypothetical prevalences (Table 2). Singleton rapid test screening predicts the presence of HIV-1 infection with high confidence in populations with an HIV-1 prevalence of 10.0% or greater. This fell sharply in hypothetical populations with a prevalence of 1.0% for the three rapid test devices with specificities less than 100%. Negative predictive values for singleton HIV-1 rapid screening were 100% for all input HIV-1 prevalences.


View this table:
[in this window]
[in a new window]
 
TABLE 2. Positive and negative predictive values for four HIV-1 rapid tests used in populations with the observed HIV-1 prevalence rate and three hypothetical rates

All four HIV-1 rapid serologic tests were as sensitive as either EIA for the detection of HIV-1 antibody. Only the UniGold HIV test was as specific as the conventional HIV-1 tests. Putative falsely reactive rapid tests were not the result of enhanced serodetection over EIA in primary HIV-1 infection, as shown by the inability to detect HIV-1 RNA in these specimens.

OraQuick HIV-1 specificity was lower in the Kericho cohort (specificity, 99.3%; 95% CI, 97.8 to 99.8%) compared with U.S.-based testing (specificity, 100%; 95% CI, 99.7 to 100%; OraQuick Rapid HIV-1 antibody test, package insert, item 3001-0951, October 2003) (P < 0.01 by Fisher's exact test). Reduced specificity with other rapid tests has been previously reported in African settings (12). Antiretrovirus-associated reduction of OraQuick HIV-1 sensitivity (16) was not observed, as these drugs were introduced into Kericho (via the President's Emergency Program for AIDS Relief) 9 months after this study concluded.

Several additional observations merit discussion. First, the use of serial EIA screening tests provided no benefit over a single-screening EIA in this high-prevalence cohort. Second, only paired EIA or EIA and UniGold HIV testing provided the same diagnostic accuracy as conventional serology. Third, the combination of two FDA-approved rapid tests, OraQuick HIV-1 and Reveal HIV-1, would have resulted in a false-positive diagnosis of HIV-1 infection in a single subject. Fourth, parallel screening with two rapid tests would not have increased the sensitivity of detection of HIV-1 antibody in the study population in agreement with recent results by others (14). Last, the PPV of screening HIV-1 rapid tests degraded significantly when applied to hypothetical populations with an HIV-1 prevalence of 1.0%. Such populations define the HIV-1 prevalence seen in sexually transmitted disease clinics in large U.S. urban areas (17), underscoring the critical need for confirmatory HIV-1 testing in these settings.

We demonstrate that robust HIV diagnostic operational research can be executed in regional field laboratories. Rapid HIV-1 tests are critical to the implementation of antiretroviral delivery programs in resource-limited areas. However, newer rapid tests with high specificity will likely be needed to best realize this goal.


arrow
ACKNOWLEDGMENTS
 
We thank Bernard M. Branson and Jose L. Sanchez for manuscript review. This study would not have been possible without the support of the employees and management of James Finlay Kenya, Ltd., and the initial efforts of Darrell Singer.

This work was supported in part by Cooperative Agreement no. DAMD17-93-V-3004, between the U.S. Army Medical Research and Materiel Command and the Henry Jackson Foundation for the Advancement of Military Medicine.

The views expressed here are the private opinions of the authors and are not to be considered as official or reflecting the views of the U.S. Army or the U.S. Department of Defense. Use of trade names is for identification only and does not imply endorsement by the U.S. government.


arrow
FOOTNOTES
 
* Corresponding author. Mailing address: Division of Retrovirology, Walter Reed Army Institute of Research, 1600 East Gude Dr., Rockville, MD 20850. Phone: (301) 251-5051. Fax: (301) 762-7460. E-mail: nmichael{at}hivresearch.org. Back


arrow
REFERENCES
 
    1
  1. Bakari, J. P., S. McKenna, A. Myrick, K. Mwinga, G. J. Bhat, and S. Allen. 2000. Rapid voluntary testing and counseling for HIV. Acceptability and feasibility in Zambian antenatal care clinics. Ann. N. Y. Acad. Sci. 918:64-76.[Medline]
  2. 2
  3. Behets, F., K. Bishagara, A. Disasi, S. Likin, R. W. Ryder, C. Brown, and T. C. Quinn. 1992. Diagnosis of HIV infection with instrument-free assays as an alternative to the ELISA and Western blot testing strategy: an evaluation in Central Africa. J. Acquir. Immune Defic. Syndr. 5:878-882.
  4. 3
  5. Behets, F. M., B. Edidi, T. C. Quinn, L. Atikala, K. Bishagara, N. Nzila, M. Laga, P. Piot, R. W. Ryder, and C. C. Brown. 1991. Detection of salivary HIV-1-specific IgG antibodies in high-risk populations in Zaire. J. Acquir. Immune Defic. Syndr. 4:183-187.
  6. 4
  7. Brattegaard, K., J. Kouadio, M. L. Adom, R. Doorly, J. R. George, and K. M. De Cock. 1993. Rapid and simple screening and supplemental testing for HIV-1 and HIV-2 infections in west Africa. AIDS 7:883-885.[Medline]
  8. 5
  9. Brenner, D., and O. Gefeller. 1997. Variation of sensitivity, specificity, likelihood ratios and predictive values with disease prevalence. Stat. Med. 16:981-991.[CrossRef][Medline]
  10. 6
  11. Centers for Disease Control and Prevention. 2001. Routinely recommended HIV testing at an urgent-care clinic, Atlanta, Georgia, 2000. Morb. Mortal. Wkly. Rep. 50:538-541.[Medline]
  12. 7
  13. Centers for Disease Control and Prevention. 1998. Update: HIV counseling and testing using rapid tests—United States, 1995. Morb. Mortal. Wkly. Rep. 47:211-215.[Medline]
  14. 8
  15. Giles, R. E., K. R. Perry, and J. V. Parry. 1999. Simple/rapid test devices for anti-HIV screening: do they come up to the mark? J. Med. Virol. 59:104-109.[CrossRef][Medline]
  16. 9
  17. Gresenguet, G., C. Tevi-Benissan, C. Payan, B. Pascal, M. Matta, M. A. Dragon, and L. Belec. 1993. Alternative strategy for the diagnosis of HIV infection in sub-Saharan Africa. Value of the sequential combination of the ELISA test and a 2nd generation rapid test. Bull. Soc. Pathol. Exot. 86:236-242.[Medline]
  18. 10
  19. Koblavi-Deme, S., C. Maurice, D. Yavo, T. S. Sibailly, K. N'Guessan, Y. Kamelan-Tano, S. Z. Wiktor, T. H. Roels, T. Chorba, and J. N. Nkengasong. 2001. Sensitivity and specificity of human immunodeficiency virus rapid serologic assays and testing algorithms in an antenatal clinic in Abidjan, Ivory Coast. J. Clin. Microbiol. 39:1808-1812.[Abstract/Free Full Text]
  20. 11
  21. Liu, A., P. H. Kilmarx, S. Supawitkul, T. Chaowanachan, S. Yanpaisarn, S. Chaikummao, and K. Limpakarnjanarat. 2003. Rapid whole-blood finger-stick test for HIV antibody: performance and acceptability among women in northern Thailand. J. Acquir. Immune Defic. Syndr. 33:194-198.
  22. 12
  23. Makuwa, M., S. Souquiere, M. T. Niangui, P. Rouquet, C. Apetrei, P. Roques, and F. Simon. 2002. Reliability of rapid diagnostic tests for HIV variant infection. J. Virol. Methods 103:183-190.[CrossRef][Medline]
  24. 13
  25. McKenna, S. L., G. K. Muyinda, D. Roth, M. Mwali, N. Ng'andu, A. Myrick, C. Luo, F. H. Priddy, V. M. Hall, A. A. von Lieven, J. R. Sabatino, K. Mark, and S. A. Allen. 1997. Rapid HIV testing and counseling for voluntary testing centers in Africa. AIDS 11:S103-S110.
  26. 14
  27. Menard, D., E. E. Mavolomade, M. J. Mandeng, and A. Talarmin. 2003. Advantages of an alternative strategy based on consecutive HIV serological tests for detection of HIV antibodies in Central African Republic. J. Virol. Methods 111:129-134.[CrossRef][Medline]
  28. 15
  29. Mitchell, S. W., S. Mboup, J. Mingle, D. Sambe, P. Tukei, K. Milenge, J. Nyamongo, O. K. Mubarak, J. L. Sankale, and D. S. Hanson. 1991. Field evaluation of alternative HIV testing strategy with a rapid immunobinding assay and an agglutination assay. Lancet 337:1328-1331.[CrossRef][Medline]
  30. 16
  31. O'Connell, R. J., T. M. Merritt, J. A. Malia, T. C. VanCott, M. J. Dolan, H. Zahwa, W. P. Bradley, B. M. Branson, N. L. Michael, and C. C. De Witt. 2003. Performance of the OraQuick rapid antibody test for diagnosis of human immunodeficiency virus type 1 infection in patients with various levels of exposure to highly active antiretroviral therapy. J. Clin. Microbiol. 41:2153-2155.[Abstract/Free Full Text]
  32. 17
  33. Schwarcz, S. K., T. A. Kellogg, W. McFarland, B. Louie, J. Klausner, D. G. Withum, and M. H. Katz. 2002. Characterization of sexually transmitted disease clinic patients with recent human immunodeficiency virus infection. J. Infect. Dis. 186:1019-1022.[CrossRef][Medline]
  34. 18
  35. Spielberg, F., C. M. Kabeya, R. W. Ryder, N. K. Kifuani, J. Harris, T. R. Bender, W. L. Heyward, and T. C. Quinn. 1989. Field testing and comparative evaluation of rapid, visually read screening assays for antibody to human immunodeficiency virus. Lancet i:580-584.
  36. 19
  37. Stetler, H. C., T. C. Granade, C. A. Nunez, R. Meza, S. Terrell, L. Amador, and J. R. George. 1997. Field evaluation of rapid HIV serologic tests for screening and confirming HIV-1 infection in Honduras. AIDS 11:369-375.[CrossRef][Medline]
  38. 20
  39. Tribble, D. R., G. R. Rodier, M. D. Saad, G. Binson, F. Marrot, S. Salah, C. Omar, and R. R. Arthur. 1997. Comparative field evaluation of HIV rapid diagnostic assays using serum, urine, and oral mucosal transudate specimens. Clin. Diagn. Virol. 7:127-132.[CrossRef][Medline]
  40. 21
  41. Webber, L. M., C. Swanevelder, W. O. Grabow, and P. B. Fourie. 2000. Evaluation of a rapid test for HIV antibodies in saliva and blood. S. Afr. Med. J. 90:1004-1007.[Medline]
  42. 22
  43. Wiley, D. J., R. R. Frerichs, W. L. Ford, and P. A. Simon. 1998. Failure to learn human immunodeficiency virus test results in Los Angeles public sexually transmitted disease clinics. Sex. Transm. Dis. 25:342-345.[Medline]
  44. 23
  45. Wilkinson, D., N. Wilkinson, C. Lombard, D. Martin, A. Smith, K. Floyd, and R. Ballard. 1997. On-site HIV testing in resource-poor settings: is one rapid test enough? AIDS 11:377-381.[CrossRef][Medline]


Journal of Clinical Microbiology, August 2004, p. 3850-3852, Vol. 42, No. 8
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.8.3850-3852.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Eller, L. A., Eller, M. A., Ouma, B. J., Kataaha, P., Bagaya, B. S., Olemukan, R. L., Erima, S., Kawala, L., de Souza, M. S., Kibuuka, H., Wabwire-Mangen, F., Peel, S. A., O'Connell, R. J., Robb, M. L., Michael, N. L. (2007). Large-Scale Human Immunodeficiency Virus Rapid Test Evaluation in a Low-Prevalence Ugandan Blood Bank Population. J. Clin. Microbiol. 45: 3281-3285 [Abstract] [Full Text]  
  • Gasasira, A. F., Dorsey, G., Kamya, M. R., Havlir, D., Kiggundu, M., Rosenthal, P. J., Charlebois, E. D. (2006). False-positive results of enzyme immunoassays for human immunodeficiency virus in patients with uncomplicated malaria.. J. Clin. Microbiol. 44: 3021-3024 [Abstract] [Full Text]  
  • Singer, D. E., Kiwanuka, N., Serwadda, D., Nalugoda, F., Hird, L., Bulken-Hoover, J., Kigozi, G., Malia, J. A., Calero, E. K., Sateren, W., Robb, M. L., Wabwire-Mangen, F., Wawer, M., Gray, R. H., Sewankambo, N., Birx, D. L., Michael, N. L. (2005). Use of Stored Serum from Uganda for Development and Evaluation of a Human Immunodeficiency Virus Type 1 Testing Algorithm Involving Multiple Rapid Immunoassays. J. Clin. Microbiol. 43: 5312-5315 [Abstract] [Full Text]  

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Foglia, G.
Right arrow Articles by Michael, N. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Foglia, G.
Right arrow Articles by Michael, N. L.