Previous Article | Next Article ![]()
Journal of Clinical Microbiology, October 2005, p. 5316-5318, Vol. 43, No. 10
0095-1137/05/$08.00+0 doi:10.1128/JCM.43.10.5316-5318.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.
Centers for Disease Control and Prevention, Office of Workforce and Career Development, Epidemic Intelligence Service, State Branch, Atlanta, Georgia,1 Tennessee Department of Health, Communicable and Environmental Disease Services,2 Vanderbilt University School of Medicine, Department of Preventive Medicine,3 Centennial Medical Center, Microbiology Laboratory, Nashville, Tennessee4
Received 1 July 2005/ Accepted 7 July 2005
|
|
|---|
|
|
|---|
Patient 1 was an infant, born at 32 weeks of gestation, admitted to the SCN on the first day of life with respiratory distress and hypoglycemia. Empirical treatment with ampicillin and gentamicin was begun. A peripheral blood sample that was drawn at admission was culture negative. An umbilical artery catheter (UAC) was placed on the third day, and the infant developed sepsis 2 days later. P. putida was cultured from blood drawn peripherally and from the catheter. Clinical improvement followed modification of the antimicrobial therapy; the umbilical artery catheter was removed on day 10, and the patient was discharged at age 3 weeks.
Patient 2 was an infant born 8 days after patient 1, at 34 weeks of gestation. Patient 2 was admitted to the SCN with respiratory distress immediately following delivery; empirical treatment with ampicillin and gentamicin was started. An umbilical artery catheter was placed 20 min after birth and discontinued on the next day. P. putida was cultured from blood drawn from the catheter following its initial insertion and flushing. Because peripheral blood cultures were negative and the patient never developed clinical signs of sepsis, the positive blood culture was interpreted as pseudobacteremia. The patient was discharged at age 2 weeks.
The isolation of P. putida from patient 2's blood sample followed the positive culture from patient 1 by 7 days; at that time, these neonates were the only patients in the SCN. No additional reports of Pseudomonas infection among hospital A patients were identified from our review of clinical microbiology laboratory records and SCN patient medical records from late 2000 through March 2001.
Environmental cultures from the SCN were obtained and included samples from lotions, soaps, work surfaces, syringes, and catheter tips. Similarly, cultures were done with samples obtained from the hospital pharmacy, including work surfaces, sinks, equipment, vials, and stock solutions. Environmental cultures of samples from faucets and surfaces were obtained from other selected areas of the hospital, including intensive care units. Cultures were also obtained for samples from the hands and nails of pharmacy workers and SCN nurses. Among the more than 130 samples tested, only one yielded P. putida. The positive sample represented an unused vial of umbilical artery catheter heparin flush solution compounded in the hospital pharmacy and was from the same batch as that used on patients 1 and 2. Genomic DNA from P. putida isolates was compared using standard methods for pulsed-field gel electrophoresis (12). P. putida isolates from the flush solution and multiple isolates from both patients all had identical DNA banding patterns (Fig. 1). Intrinsic contamination (6) was ruled out by the absence of similar reports from other hospitals and by sterility testing of unopened stock solutions from the same lots of saline (n = 2) and heparin (n = 10) used to prepare the flush solution.
![]() View larger version (101K): [in a new window] |
FIG. 1. Pulsed-field gel electrophoresis of genomic DNA from Pseudomonas putida isolates following overnight digestion with SpeI. Isolates were obtained from patient blood cultures and an unused container of umbilical artery catheter flush solution from the same batch used on the patients.
|
We reviewed hospital A's pharmacy practices related to the preparation of sterile products, including the observation of a mock preparation of UAC heparin flush solution. Although the exact source or mechanism of contamination could not be identified, several pharmacy practices may have led to unrecognized extrinsic contamination. The flush solution was prepared in a class 100 laminar-flow hood by pharmacy technicians who were typically not wearing gloves or other protective attire (e.g., laboratory jacket, gown, or mask), as required by state regulations and related guidelines when the anticipated dispensing time is >28 h away (2, 3). Each vial was prepared by using sterile syringes to transfer, separately, 1.5 ml of a 10-unit/ml concentration of preservative-free heparin flush (obtained from 1-ml vials) and 28.5 ml of 0.5 N saline into a sterile 30-ml vial. The saline was obtained from a 500-ml bag, which was opened <24 h before use. Notably, the heparin vial and saline bag stoppers were wiped using pads that were stacked in an open container of 70% alcohol, rather than the standard individually foil-wrapped alcohol pads. This might have facilitated the introduction of bacterial contaminants from a technician's hand or other source. Completed vials of flush solution were sealed and held under refrigeration until dispensed, with a 30-day expiration limit. Sterility testing of the final product was not performed. We also found that vial labeling did not always identify the technician who compounded the sterile product and that log records for prepackaged compounded solutions were sometimes incomplete.
To evaluate the effects of potential extrinsic contamination during the preparation of preservative-free flush solutions, we investigated the in vitro persistence of P. putida in a half-strength normal saline plus heparin solution. The saline-heparin solution was prepared by taking 28.5 ml of sterile 0.5 N saline and adding 1.5 ml of a 10-unit/ml concentration of heparin flush solution. This saline-heparin solution was then filter sterilized with a 0.45µm filter and added to sterile glass bottles in 30-ml aliquots. Colonies of P. putida obtained from overnight growth on sheep blood agar were suspended in the same sterile saline-heparin solution to achieve a 0.5 MacFarland standard. Dilutions of this suspension were then inoculated into the bottles of the saline-heparin solution to yield approximate initial concentrations of 102 and 103 CFU/ml. Four bottles of each concentration were incubated at either room temperature (21°C to 22°C) or refrigerator temperature (4°C to 5°C). A 0.1-ml sample of the inoculated saline-heparin solution was removed from each bottle on days 0 to 7, 14, 21, and 35 by using a sterile syringe and plated onto sheep blood agar; colony counts were determined using a standard method (15) after 24 h of incubation at 32°C. The in vitro survival curves for P. putida incubated at either room or refrigerator temperature demonstrated persistence, with generally stable or increasing colony counts following an initial decrease during the first week (Fig. 2). Even under refrigerated conditions, the 102- and 103- CFU/ml inocula exhibited growth at 21 and 35 days, respectively.
![]() View larger version (9K): [in a new window] |
FIG. 2. In vitro survival curves for Pseudomonas putida in 0.5 N saline plus heparin. Survival was monitored at room temperature (21°C to 22°C) (dash-dot line) and at refrigerator temperature (4°C to 5°C) (solid line) for two levels of inocula: 102 CFU/ml (fine lines) and 103 CFU/ml (heavy lines).
|
Lack of adherence to sterile practices by pharmacies compounding injectable medications represents an important patient safety concern (7, 14, 16). To address this problem, a series of recommendations and guidelines that address pharmacy-prepared sterile products have been developed (1, 2). Adherence to these guidelines, however, has left much room for improvement and suggests that conditions similar to those described in the hospital A pharmacy were not atypical of many hospital pharmacies in the United States (13). The publication in 2004 of enforceable practice standards for compounding sterile preparations was an encouraging development (10). Growing awareness and implementation of these standards are needed to further improve the safety of sterile products administered to neonates and other patients.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»