Previous Article | Next Article ![]()
Journal of Clinical Microbiology, April 2005, p. 1581-1586, Vol. 43, No. 4
0095-1137/05/$08.00+0 doi:10.1128/JCM.43.4.1581-1586.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.
Department of Oral Health Sciences,1 Division of Functional Morphology, Dental Research Center, Nihon University School of Dentistry, Tokyo,2 Department of Preventive Dentistry, Faculty of Dental Science, Kyushu University, Fukuoka, Japan3
Received 30 August 2004/ Returned for modification 14 October 2004/ Accepted 24 November 2004
|
|
|---|
|
|
|---|
The molecular methods that have been used to date (3, 6, 17) are expensive and complicated to perform. Varying degrees of success have been realized using PCR-based assays for detecting S. pneumoniae with primers specific to repetitive regions or to genes encoding rRNA (7, 9, 12), pneumolysin (18, 19, 23), or autolysin (5, 14, 18). Autolysin and pneumolysin, which are encoded by the lytA and ply genes, respectively, represent potential targets for the specific detection of S. pneumoniae. Both genes are essential for pathogenesis and are well-characterized virulence markers (1). The restricted allelic variation of lytA (4, 21) makes this gene an ideal target for specific identification in clinical and epidemiological studies. For example, the gene may allow the differentiation of S. pneumoniae from the genotypically similar species Streptococcus mitis and Streptococcus oralis, which are commensals of the human oral cavity (11).
The application of this strategy was complicated by the recent report of organisms that are genetically and phenotypically related to S. mitis yet harbor pneumolysin and autolysin genes (22), which were previously thought to be associated with pneumococci. This could result in the possible overestimation of S. pneumoniae (20). However, there are several variations in the autolysin gene sequences of nonpneumococcal organisms compared to the sequences of S. pneumoniae strains. Clarifying and using the consensus sequence for S. pneumoniae strains could lead to the more highly specific and sufficiently reliable molecular diagnosis of S. pneumoniae infection.
In seeking such diagnostic specificity, we investigated the applicability of a novel nucleic acid amplification method, loop-mediated isothermal amplification (LAMP) (16). LAMP amplifies DNA with high specificity, efficiency, and speed under isothermal conditions. The LAMP reaction requires a DNA polymerase with strand displacement activity and a set of four specially designed inner and outer primers that recognize six distinct sequences on the target DNA. Only simple, cost-effective equipment amenable for use in hospital laboratories is required. This method also exhibits extremely high amplification efficiency, owing, in part, to its isothermal nature; no time is lost as a result of changes in temperature, and the reaction can be conducted at the optimal temperature for enzyme function. Moreover, the inhibition reaction that occurs at later stages of amplification, which typically confounds PCR, is less likely to occur. Therefore, LAMP constitutes a potentially valuable tool for the rapid diagnosis of infectious diseases, such as those caused by S. pneumoniae, in commercial or hospital laboratories.
Our goal was to establish a highly sensitive and species-specific LAMP-based S. pneumoniae DNA amplification method and to examine its reliability in discriminating among species.
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Specificity of the LAMP primers used to identify S. pneumoniae
|
![]() View larger version (36K): [in a new window] |
FIG. 1. (A) Nucleotide sequences of S. pneumoniae R6 autolysin gene used for LAMP primer. The sequences used for LAMP primers are shown in boldface. *, consensus sequence among S. pneumoniae strains. (B) Schematic representation of primers used in this study.
|
Analysis of LAMP products. The LAMP reaction causes turbidity in the reaction tube proportional to the amount of amplified DNA. Therefore, we observed the turbidity in the reaction tube with the naked eye. For further confirmation, the amplified products were also detected using electrophoresis in 3% agarose gels, followed by ethidium bromide staining. To confirm the sensitivity and the possibility of real-time LAMP quantification of S. pneumoniae, a Loopamp real-time turbidimeter (LA-200; Teramecs, Kyoto, Japan) was used.
To confirm the structures of the amplified products, some of the amplified products were digested with the restriction enzyme TasI (Fermentas Inc., Hanover, Md.) and their sizes were analyzed by electrophoresis in 3% agarose gels, followed by staining with ethidium bromide. Furthermore, to confirm the structure of the amplified LAMP products, the amplified products were sequenced using a BigDye Terminator V3.1 cycle sequencing kit (Applied Biosystems, Foster City, Calif.) and an ABI PRISM 377 DNA sequencer (Applied Biosystems) in accordance with the manufacturers' instructions. The primers used to sequence the target region (between F1 and B1) were as follows: F2 primer, 5'-CACTCAACTGGGAATCCGC-3', and B2 primer, 5'-CCAGGCACCATTATCAACAGG-3' (Fig. 1).
PCR assay. Template DNA from clinical isolates was used at identical concentrations for the LAMP and conventional PCR assays. Sensitivity was compared using autolysin (lytA)-encoding PCR primer sets (14), and selectivity was compared using autolysin (lytA)- and pneumolysin (ply)-encoding PCR primer sets (14, 19). The sequences of the PCR primers were as follows: for lytA, 5'-CAACCGTACAGAATGAAGCGG-3' and 5'-TTATTCGTGCAATACTCGTGCG-3', and for ply, 5'-ATTTCTGTAACAGCTACCAACGA-3' and 5'-GAATTCCCTGTCTTTTCAAAGTC-3'.
The PCR mixture (10 µl) consisted of 0.2 mM concentrations of each deoxyribonucleoside triphosphate, 10 mM Tris-HCl buffer (pH 8.3), 50 mM KCl, 2 mM MgCl2, 1 U of Ex Taq DNA polymerase (TaKaRa Bio Inc.), 0.5 µM concentrations of each primer, and 1 µl of template DNA. PCR was performed with a thermal cycler (MJ Research, Waltham, Mass.) for 30 cycles. Each cycle consisted of 1 min at 94°C, 1 min at 55°C, and 1 min at 72°C for the ply gene and 15 s at 94°C, 15 s at 53°C, and 15 s at 72°C for the lytA gene. Samples (2 µl) of the PCR amplification products were subjected to electrophoresis on a 3% agarose gel.
Clinical isolates with ply or lytA genes. From 15 oral mucosa swab samples of healthy children (5 to 6 years old), we isolated 25 alpha-hemolytic streptococci in which genes encoding pneumolysin (ply) or autolysin (lytA) were detected using conventional PCR with the primers described above (14, 19). The identification of these isolates involved standard criteria, as follows. The optochin sensitivity test used a 6.5-mm-diameter disk containing 5 µg of optochin (Eiken Chemical Co., Ltd., Tochigi, Japan) in an atmosphere of 5% CO2. The absence of an inhibition zone at least 13 mm in diameter was interpreted as a negative result, whereas a zone of inhibition at least 13 mm in diameter constituted a positive result. Bile solubility was tested, as previously described (8). A commercial system, API 20 Strep (bioMérieux, Lyon, France), was used according to the manufacturer's instructions.
|
|
|---|
|
View this table: [in a new window] |
TABLE 2. Sensitivities of the LAMP and PCR assays for S. pneumoniae ATCC 6305
|
![]() View larger version (112K): [in a new window] |
FIG. 2. Sensitivities of electrophoretic analysis of LAMP-amplified products. Lanes M, 100-bp ladder used as a size marker; lane 1, 106 copies of genomic DNA from S. pneumoniae ATCC 6305; lane 2, 105 copies; lane 3, 104 copies; lane 4, 103 copies; lane 5, 102 copies; lane 6, 10 copies; lane 7, 1 copy; lane 8, no template; lane 9, LAMP product from lane 1 after TasI digestion. The digested fragments were 102 and 111 bp.
|
To evaluate the species specificity of the LAMP primers, we tested 10 Streptococcus species and 7 non-Streptococcus species (Table 1). Significant amplification of the DNA originating from S. pneumoniae was observed after a 35-min incubation. By contrast, the other strains were not amplified, even after a 60-min incubation. The specificity of the amplification was confirmed by TasI digestion to ensure that the amplification product had sequences corresponding to the selected target. The resulting digestion products were 102 and 111 bp, in good agreement with the predicted size (Fig. 2). The structures of the amplified products were confirmed by sequencing, and the obtained sequences were compared to sequences in the targeted region in the lytA gene (bases 132 to 152 in the original sequence) of S. pneumoniae strains (between F1 and B1) (Fig. 1). These results matched the expected nucleotide sequences perfectly (data not shown).
Previously, we isolated 25 alpha-hemolytic streptococci in which genes encoding pneumolysin (ply) or autolysin (lytA) were detected using conventional PCR. Using three standard tests (the optochin sensitivity test, the bile solubility test, and API 20 Strep [bioMérieux]), we identified 4 S. pneumoniae strains and 21 atypical strains, including 3 S. oralis, 17 S. mitis, and 1 streptococcus species (Table 3). To confirm its ability to evaluate clinical isolates, the LAMP assay was used to screen these 25 isolates (Table 3). The concentration of genomic DNA in each isolate was 106 copies per assay mixture, allowing direct comparison of the results of the PCR and LAMP assays. LAMP detected 4 positive isolates and 21 negative isolates; PCR detected 8 positive isolates and 17 negative isolates for the lytA gene and 21 positive isolates and 4 negative isolates for ply gene. Moreover, the LAMP assay detected the 4 S. pneumoniae isolates and none of the 21 other isolates while PCR produced 4 false-positive results for lytA and 17 false-positive results for ply.
|
View this table: [in a new window] |
TABLE 3. Detection of Streptococcus pneumoniae in clinical isolates of oral streptococci by PCR and LAMP methods
|
![]() View larger version (29K): [in a new window] |
FIG. 3. (A) Real-time sensitivity of S. pneumoniae LAMP, as monitored by the measurement of turbidity. Shown from left to right in the figure are the curves of decreasing concentrations (1,000,000 to 1) of bacteria. The detection limit was 10 copies. (B) The relation between the threshold times (Tt) of each sample and the log of the amount of initial template DNA.
|
|
|
|---|
PCR-based technology holds more promise. Concerning pneumococci, the putative virulence factors pneumolysin (ply) and autolysin (lytA) offer compellingly specific diagnostic targets. As yet, however, PCR has not established a routine foothold in clinical laboratories because it is a time-consuming complex and needs a high-precision thermal cycler. Reaction equipment that is much simpler and amenable for use in hospital laboratories is required.
By contrast, the LAMP assay reported here is advantageous owing to its simple operation, rapid reaction, and easy detection. LAMP operates under isothermal conditions at 63°C for 1 h. Therefore, no time is lost as a result of changes in temperature, as is the case with thermal cycling with PCR. Moreover, LAMP requires only simple reaction equipment; it can be performed using a regular laboratory bath or heat block that provides a constant temperature of 63°C. It is even possible to determine the reaction directly with the naked eye, without electrophoretic analysis, unlike PCR. Since the LAMP assay is simple and relatively easy to perform, even a clinical microbiological laboratory that has not performed PCR or molecular testing could introduce this technology.
In this study, of 25 clinical isolates that harbored virulence-factor-encoding genes (lytA or ply), 17 nonpneumococcal isolates were detected for the ply gene (Table 3). This result was concordant with a report of the presence of pneumolysin in viridans group streptococci which concluded that the ply gene is not specific for S. pneumoniae while the lytA gene is highly specific for S. pneumoniae (15). It was thought that lytA separated S. pneumoniae from the genotypically similar species S. mitis and S. oralis (11). Recently, however, the existence of organisms that appear to be genetically and phenotypically related to S. mitis, but which harbor the autolysin gene normally associated with pneumococci, was reported (22). In fact, we detected 4 nonpneumococcal isolates for the lytA gene out of 25 clinical isolates (Table 3). We must now consider how to differentiate S. pneumoniae from closely related alpha-hemolytic streptococci.
Fortunately, there are several variations of autolysin genes in nonpneumococcal organisms to the lytA gene sequences of S. pneumoniae type strains. Therefore, by clarifying and using these consensus genes for S. pneumoniae, a more specific and sufficiently reliable molecular diagnosis of S. pneumoniae infection should be possible. In addition, the selectivity of the LAMP reaction is extremely high because it uses four primers that recognize six distinct regions of the target DNA (16). From the alignment analysis of the lytA gene sequences among four S. pneumoniae strains and nine other streptococcus strains that harbor the autolysin gene, we were able to evaluate the lytA consensus sequence specific for S. pneumoniae strains (Fig. 1A). Then, we designed LAMP primers including these S. pneumoniae-specific consensus sequences (Fig. 1A). This may have influenced the high selectivity of the LAMP assay and might be why LAMP did not detect the four nonpneumococcal strains in which PCR detected lytA (Table 3).
As the LAMP reaction progresses, the reaction by-product pyrophosphate ions bind to magnesium ions and form a white precipitate of magnesium pyrophosphate. Therefore, the results of the LAMP reactions can be judged simply by the naked eye. This characteristic feature of the LAMP reaction can be used to detect the reaction end point simply by gauging the presence of a precipitate. In 2004, Mori et al. (13) reported that real-time turbidity measurements of the LAMP reaction by using a simple, inexpensive apparatus (Loopamp real-time turbidimeter) permits quantitative analysis of the minute amounts of nucleic acids present in a sample, with a high degree of precision, over a wide range. In this study, we also tried to use the LAMP assay to quantify template S. pneumoniae in real time by reading the optical density at 650 nm every 6 s with a Loopamp real-time turbidimeter.
The curve obtained using the real-time turbidity measurements had a high linearity (Fig. 3B). This indicated that the quantity of template DNA of an unknown concentration can be determined by comparing its threshold time with the threshold times of template DNA of known concentrations. Therefore, using the real-time turbidity monitoring system, we will be able to estimate the concentration of S. pneumoniae DNA from clinical samples. In the clinical laboratory, optochin and bile reactions can be replaced by a LAMP test. Alternatively, we can utilize this technique for direct detection from clinical specimens in order to reduce laboratory time. In this case, quantitative detection using the Loopamp real-time turbidimeter is helpful for the diagnosis of pneumococcal infection.
In conclusion, we have established a LAMP-based S. pneumoniae DNA amplification method and we report that its reliability in species discrimination is high. This assay may allow more sensitive, specific, and practical detection of S. pneumoniae than previous detection methods. LAMP is potentially useful for the reliable routine diagnosis of S. pneumoniae infections.
We are grateful to Muneaki Tamura, Department of Bacteriology, Nihon University School of Dentistry, and Yutaka Arimoto, Department of Pediatrics, St. Marianna University School of Medicine, for their contributions to this work. We are also thankful to Kazumitu Sano, Department of Clinical Laboratory, Nerima-Hikarigaoka Nihon University Hospital, for his technical support in this study.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»