Previous Article | Next Article ![]()
Journal of Clinical Microbiology, July 2005, p. 3290-3296, Vol. 43, No. 7
0095-1137/05/$08.00+0 doi:10.1128/JCM.43.7.3290-3296.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.
Department of Microbiology,1 Department of Ophthalmology, Fukushima Medical University School of Medicine, 1 Hikarigaoka, Fukushima 960-1295,2 Visual Sciences, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido 060-8638, Japan3
Received 4 October 2004/ Returned for modification 20 November 2004/ Accepted 10 March 2005
|
|
|---|
|
|
|---|
HSV-1 and HSV-2 infections and even some VZV infections cause similar clinical symptoms, for example, cutaneous vesicles, keratitis, and acute retinal necrosis (ARN), and the causative agent cannot be distinguished based on the clinical features. However, different clinical courses and prognoses are caused by each virus. HSV-2 genital herpes tends to recur, but HSV-1 genital herpes does not (7). VZV ARN is severer and has a worse prognosis than HSV ARN (4). The identification of the virus is important for the determination of treatment and for an understanding of the clinical progress and prognosis; therefore, an effective laboratory method is urgently needed for the diagnosis of HSV-1, HSV-2, and VZV infections.
At present, molecular methods such as dot blotting, in situ hybridization, and PCR have been developed for pathogen detection. In particular, PCR has been used for numerous recent applications for pathogen detection and pathology research. However, these methods require precision instruments for amplification and DNA extraction, which are the major obstacles to the widespread use of these methods in relatively small-scale clinical laboratories such as those in private clinics. Recently, a new, rapid, and sensitive technique called loop-mediated isothermal amplification (LAMP) was developed (13). LAMP is a nucleic acid amplification method which relies on autocycling strand-displacement DNA synthesis performed by the Bst DNA polymerase large fragment. The amplification products are stem-loop DNA structures with several inverted repeats of the target and structures with multiple loops. The LAMP reaction can be conducted under isothermal conditions ranging from 60 to 65°C by using only one type of enzyme and four primers recognizing six distinct regions. The most important merit of this method is that no denaturation of the DNA template is required (11). Moreover, when two primers, termed loop primers, are added, the LAMP reaction time can be shortened (12). With this modification, the LAMP method is able to amplify the target DNA in a shorter time than and with an extremely high specificity compared to the PCR method. Moreover, the LAMP method produces a large amount of amplified product, resulting in easier detection, such as detection by visual judgment based on the turbidity or fluorescence of the reaction mixture (10). Recently, several investigators have reported the rapid identification of Mycobacterium (6), human herpesvirus 6 (5), human herpesvirus 7 (22), West Nile virus (14), and the severe acute respiratory syndrome coronavirus (3) and have commended the usefulness of the LAMP assay.
For the present study, we used a LAMP assay as the detection system for the diagnosis of HSV-1, HSV-2, and VZV infections. The sensitivity, specificity, and applicability of this method for the direct detection of HSV-1, HSV-2, and VZV from clinical specimens were also evaluated.
|
|
|---|
DNA extraction. Virus DNA was extracted from infected cells or clinical samples by proteinase K treatment and phenol-chloroform extraction. After ethanol precipitation, the DNA was suspended in H2O and stored at 20°C until use.
LAMP method. We used six primers for the LAMP assay, including two outer primers (F3 and B3), a forward inner primer (FIP), a backward inner primer (BIP), and two loop primers (LPF and LPB). The location and sequence of each primer are shown in Fig. 1 and Table 1, respectively. FIP consisted of F1 and F2, and BIP consisted of B1 and B2. F3 and B3 were located outside of F2 and B2. Since additional loop primers increase the amplification efficiency, we also synthesized loop primers (LPF and BPF). HSV-1-, HSV-2-, and VZV-specific primers were designed to target the UL1 to UL2, US4, and ORF62 gene regions, respectively. In order to design virus-specific primers, we selected regions of low homology with the nucleotide sequences of the other two viruses.
![]() ![]() ![]() View larger version (94K): [in a new window] |
FIG. 1. Location and sequence of LAMP target and primer regions for HSV-1 (A), HSV-2 (B), and VZV (C). The single nucleotide polymorphisms of three HSV-1 strains (the G1-4, conj10, and KH15 strains) are shaded. Arrows indicate the nucleotide bases of strains with polymorphism.
|
|
View this table: [in a new window] |
TABLE 1. Primers used for LAMP
|
PCR. For an assessment of the sensitivity of the LAMP assay for HSV-1 and HSV-2, PCRs were performed with three primer sets. The first primer set (primer set 1) was B3 and F3, as used in the LAMP assay for HSV-1 and HSV-2 (Table 1). Secondly, we designed a primer set (primer set 2) for HSV-1 and HSV-2 (Table 2). PCR amplification was performed in 15-µl reaction mixtures containing 10 mM Tris, 50 mM KCl, 1.5 mM MgCl2, a 200 µM concentration of each deoxynucleoside triphosphate, a 500 nM concentration of each primer, and 0.5 unit of Taq DNA polymerase. Initial denaturation was done at 95°C for 3 min, followed by 40 cycles of denaturation (30 s at 95°C), annealing (1 min at 55°C and 50°C for primer set 1 and primer set 2, respectively), and extension (45 s at 72°C).
|
View this table: [in a new window] |
TABLE 2. Primers used for PCR
|
Quantification of HSV DNA. The copy numbers in HSV-1 and HSV-2 DNA samples were analyzed by real-time PCR using a LightCycler (Roche Molecular Biochemicals). For each assay, 2 µl of an extracted DNA sample was added to 18 µl of PCR mixture in each reaction capillary, according to the manufacturer's instructions. The PCR mixture contained 1x FastStart DNA polymerase reaction buffer including deoxynucleoside triphosphates, Taq polymerase, and SYBR green I (Roche Molecular Diagnostics), 3 mM MgCl2, and a 0.5 µM concentration of each of the primers. The sequences of the primers for HSV-1 were 5'-TGTGGTCGTCGACGATTGCAGCAT-3' and 5'-TGGGAGTGACCCGCGTGGTCGA-3', and those for HSV-2 were 5'-CTACGACGCGTACCGGTCCGATG-3' and 5'-GTGGTGCACGAACAGCGTGGTGA-3'. After denaturation for 10 min at 95°C, 40 cycles of amplification at 95°C for 0 s, 55°C for 10 s, and 72°C for 20 s were carried out. The amount of amplified product for the targeted nucleic acid was monitored by SYBR green I staining during each cycle of the PCR. Prediluted standard DNA templates comprising 103 to 107 copies of a quantified PCR product were applied to the real-time PCR analysis to make a standard curve. The copy numbers of HSV-1 and HSV-2 DNA were then determined by using the standard curve.
DNA sequencing of virus strains. The nucleotide sequences of the LAMP target and primer regions in the HSV-1, HSV-2, and VZV strains were determined by a PCR-directed sequencing method. Briefly, double-stranded DNA templates for sequencing reactions were prepared by PCRs using the primer sets shown in Table 2 as described previously (18). PCR products from the HSV-1, HSV-2, and VZV strains were purified with a QIAquick PCR purification kit (QIAGEN, Hilden, Germany) and used as templates for DNA sequencing reactions. Nucleotide sequencing was performed by use of an autosequencer (ABI PRISM 3100 genetic analyzer) and a commercial kit (BigDye; Applied Biosystems, Foster City, Calif.).
Clinical samples. We evaluated samples for 40 cases of genital herpes and 20 cases of ocular herpes. The genital samples were vaginal smears from patients suspected of having genital herpes. Ocular herpes samples were obtained from 5 patients with herpetic dendritic keratitis and 15 patients with uveitis and suspected ARN. Keratitis samples were corneal smears and uveitis samples were from aqueous (n = 6) and vitreous (n = 9) fluid. The smear samples were scraped with a cotton swab and placed in 0.5 ml of DMEM. Aqueous samples were obtained by anterior chamber paracentesis. Vitreous samples were obtained at the time of surgery. All samples were stored at 80°C until use. LAMP, PCR, and virus isolation were performed for all clinical samples. The sequences of the PCR primers are summarized in Table 2.
|
|
|---|
![]() View larger version (73K): [in a new window] |
FIG. 2. Electrophoretic analysis of LAMP-amplified products. Lanes 1, 2, and 3, LAMP carried out with HSV-1 primers and genomic DNAs from HSV-1, HSV-2, and VZV, respectively; lane 4, LAMP product from lane 1 after digestion with PstI; lanes 5, 10, and 15, LAMP carried out in the absence of template DNA with the HSV-1, HSV-2, and VZV primers, respectively; lanes 6, 7, and 8, LAMP carried out with HSV-2 primers in the presence of genomic DNAs from HSV-1, HSV-2, and VZV, respectively; lane 9, LAMP product from lane 7 after digestion with HaeIII; lanes 11, 12, and 13, LAMP carried out with VZV primers in the presence of genomic DNAs from HSV-1, HSV-2, and VZV, respectively; lane 14, LAMP product from lane 13 after digestion with AluI. The positions of size markers are shown on the left.
|
Sensitivity of LAMP assay for HSV-1 and HSV-2. The sensitivity of the LAMP assay for HSV-1 and HSV-2 was determined by testing serial 10-fold dilutions of samples for which the copy numbers of virus DNA had previously been quantified by real-time PCR and comparing the results with those of PCR. The analyzed strains showed 100% nucleotide sequence homology in the LAMP primer region. In order to check the sensitivity of PCR accurately, we carried out a PCR assay using three primer sets. Primer set 1 consisted of B3 and F3 from the HSV-1 and HSV-2 LAMP assays, with which regions of low nucleotide sequence variation were proven in this study. The sensitivity of this primer set was much lower than those of primer set 2 and primer set 3 (data not shown). The PCR assay using primer set 2 or primer set 3 had a detection limit of 100 copies/tube. Therefore, we used primer set 2 for this study.
The HSV-1 and HSV-2 LAMP assay could detect as few as 10 copies/tube, which was a 10-fold higher sensitivity than that of the PCR assays with primer set 2 (Table 2) and primer set 3. We studied the influence of nucleotide polymorphisms in the primer region on the sensitivity of the LAMP assay by using three HSV-1 strains. The detection limit for all three strains was 10 copies/tube, and there were no differences in the sensitivity of the LAMP assay for HSV-1, regardless of the presence of single nucleotide variations (Fig. 3).
![]() View larger version (114K): [in a new window] |
FIG. 3. Comparative sensitivities of LAMP and PCR for the detection of HSV-1 (A) and HSV-2 (B). Amplification by LAMP shows a ladder-like pattern, whereas that by primer set 2 and primer set 3 shows single bands for the amplification products obtained by using the primer set shown in Table 2 and that from a commercial PCR kit, respectively. (C to E) Comparative sensitivities to single nucleotide polymorphisms of three HSV-1 strains. The electrophoretic profiles of the G1-4 strain (C), the conj10 strain (D), and the KH15 strain (E) are shown. Lanes: 1, 106 copies/tube; 2, 105 copies/tube; 3, 104 copies/tube; 4, 103 copies/tube; 5, 102 copies/tube; 6, 101 copies/tube; 7, 100 copies/tube; 8, negative control without target DNA.
|
|
View this table: [in a new window] |
TABLE 3. Comparison of LAMP assay and PCR assay by using clinical samples
|
|
|
|---|
The nucleotide sequences of HSV-1 and HSV-2 have high homology, and regions of nucleotide sequence specificity between HSV-1 and HSV-2 are limited. We found sequence specificity for HSV-1 and HSV-2 in the UL1 to UL2 genes and the US4 gene, respectively; therefore, we designed primers to target these regions. The sequences of the HSV-1-specific forward primers (F3, FIP, and LPF) have high homology to HSV-2, but the reverse primers (B3, BIP, and BPF) are specific for HSV-1. All HSV-2-specific LAMP primers had a low homology with HSV-1. The virus specificities of these primers were confirmed in our study.
An evaluation of three strains with single nucleotide sequence variations showed that there was no difference in the sensitivity of the LAMP assay for these HSV-1 strains. Sakaoka et al. reported that the nucleotide diversity of HSV-1 was 0.0037 (3 or 4 nucleotides per 1,000 bases) between any two strains (16). The nucleotide diversity in the LAMP target and primer regions of 271 bp of 50 HSV-1 strains was 0.00044 (4 or 5 nucleotides per 10,000 bases). Thus, the LAMP target and primer regions of HSV-1 are regarded as having adequately low degrees of variation. Compared to HSV-1, HSV-2 and VZV have little nucleotide diversity among strains (2, 17, 19). Our sequencing study indicated that the targeted regions of HSV-2 and VZV have no nucleotide sequence variation and are also adequate for the LAMP assay.
In an evaluation of clinical samples, 30 of 40 patients suffering from genitalitis were identified as having HSV-1 or HSV-2 infection by a LAMP assay with samples subjected to DNA extraction. We could not diagnose whether the other 10 patients suffered from HSV infection or other diseases. In the case of keratitis, the diagnosis of herpes keratitis is relatively easy on the basis of its typical symptom, dendritic keratitis, so the frequency of HSV infection was high (four of five cases). However, the frequency of HSV detection in uveitis samples was low because the frequency of ARN during uveitis is low.
We paid attention to and evaluated the two methods by using clinical samples. We first evaluated the sensitivity of LAMP compared to that of PCR, using samples subjected to DNA extraction. Both LAMP and PCR showed the same sensitivity for identifying genital herpes and herpetic keratitis. However, three of seven LAMP-positive uveitis samples were negative in the PCR assay. This indicated that the sensitivity of LAMP is high enough to detect low DNA copy numbers and is therefore useful for small-volume samples such as those of vitreous and aqueous humor. Next, we evaluated the necessity of DNA extraction. Biological fluids, e.g., aqueous and vitreous humor, contain substances that inhibit PCR (8, 9, 15, 21). Therefore, samples for PCR assays require DNA extraction. Using direct sample fluid (in DMEM) with genital smear suspensions, we identified HSV-1 or HSV-2 in 21 samples by LAMP and in just 1 sample by PCR. Using direct ocular sample fluid, we found that 5 of the 11 samples that were positive after DNA extraction were also positive in the LAMP assay, but none were positive in the PCR assay. The inhibitory substances reduced the sensitivity of PCR, resulting in a PCR sensitivity which was lower than that required for virus isolation. These results indicate that the LAMP assay is more tolerant of substances contained in clinical specimens than is PCR.
In conclusion, the LAMP assay is a simple, rapid, and accurate nucleoside amplification method that is useful for the clinical diagnosis of HSV and VZV infection. Compared to PCR, the LAMP assay possesses advantages in its sensitivity and tolerance of inhibitory substances. These results suggest that the LAMP assay could be introduced into clinical laboratories and even private clinics.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»