Previous Article | Next Article ![]()
Journal of Clinical Microbiology, June 2006, p. 1998-2006, Vol. 44, No. 6
0095-1137/06/$08.00+0 doi:10.1128/JCM.00104-06
Copyright © 2006, American Society for Microbiology. All Rights Reserved.
and
Eduardo Franco3
Laboratoire de Virologie Moléculaire du Centre de Recherche, Départements de Microbiologie et Infectiologie, Obstétrique-Gynécologie et Gastro-entérologie, Hôpital Notre-Dame du Centre Hospitalier de l'Université de Montréal, Montréal, Québec, Canada,1 Département de Microbiologie et Immunologie, Université de Montréal, Montréal, Québec, Canada,2 Division of Cancer Epidemiology and Department of Medicine, McGill University, Montreal, Quebec, Canada,3 Roche Molecular Systems, Alameda, California,4 Direction de la Santé Publique de Montréal-Centre, Institut National de Santé Publique du Québec, Montréal, Québec, Canada,5 Clinique Médicale l'Actuel, Montréal, Québec, Canada,6 Clinique Médicale du Quartier-Latin, Montréal, Québec, Canada,7 Division of Clinical Investigation and Human Physiology, Toronto General Research Institute, Toronto General Hospital, University of Toronto, Toronto, Canada8
Received 17 January 2006/ Returned for modification 7 March 2006/ Accepted 17 March 2006
|
|
|---|
|
|
|---|
The most common PCR methods use the consensus primer set MY09/MY11/HMB01 (20, 25), GP5+/GP6+ (9, 21), PGMY09/PGMY11 (13, 34), or SPF10 (30, 34). Convenient assays for detection and typing of HPV have been developed for all of these primer sets. HPV amplicons generated by PGMY or MY primers can easily be detected and typed by a nonisotopic reverse hybridization assay, the line blot assay (14). In previous studies, the reverse line blot assay combined with PCR using the MY09-MY11 or PGMY09-PGMY11 primers compared favorably to a dot blot assay using type-specific radiolabeled oligonucleotide probes for HPV typing of PCR-amplified products (6, 7, 23).
Consensus L1 PGMY09/11 primers were reported to improve the sensitivity for HPV detection over that of the MY09/MY11/HMB01 primers (6, 12, 13, 23). The research prototype version of the assay, the PGMY line blot assay (PGMY-LB), has been further developed and is now commercially available from Roche Molecular Systems under the designation Linear Array HPV genotyping test (LA-HPV). The reagents used for LA-HPV are now standardized and produced under quality-controlled conditions. Amplification profiles and reagents have been optimized to increase the sensitivity and reproducibility, mainly by avoiding competition during coamplification of ß-globin and HPV DNA (J. Kornegay, personal communication). The use of standardized protocols for HPV detection and typing increases the reproducibility of results and should facilitate the comparison of results between studies (22).
The aim of the present study was to compare results obtained with PGMY-LB and LA-HPV for 528 anogenital specimens collected from 236 men and 146 women for HPV DNA detection and typing. The potential to separately identify types in multiple-type infections, a frequent occurrence in human immunodeficiency virus (HIV)-seropositive hosts, was also explored. The rates of detection of the 37 genotypes were compared between assays. This information is useful in view of the wider use of LA-HPV by numerous research groups as well as its potential application in diagnostic laboratories for HPV typing.
|
|
|---|
LA-HPV. PCR was performed in a final reaction volume of 100 µl with 50 µl of kit working master mix containing MgCl2, KCl, AmpliTaq Gold DNA polymerase, uracil-N-glycosylase, dATP, dCTP, dGTP, dUTP, dTTP, and biotinylated PGMY primers and ß-globin primers GH20 and PC04. The mixture was incubated in a TC 9700 thermal cycler set at maximum ramp speed for 2 min at 50°C and 9 min at 95°C, followed by 40 cycles of 30 s at 95°C, 1 min at 55°C, and 1 min at 72°C, with a final extension at 72°C (ramp rate set at 50%) for 5 min. Biotinylated amplicons were denatured in 0.4 N NaOH and hybridized to an immobilized probe array containing probes for 37 HPV genotypes according to the protocol provided by Roche Molecular Systems. Positive hybridization reactions were detected by streptavidin-horseradish peroxidase-mediated color precipitation on the membrane at the probe line. The probe for detection of HPV-52 amplicons on the array was a cross-reactive probe that also hybridized with types 33, 35, and 58. Samples positive with the HPV-52 cross-reactive probe and containing at least one of these types were also tested with a real-time PCR assay specific for type 52 validated in the laboratory of F. Coutlée (unpublished data; see below). Only samples reactive in the HPV-52 real-time PCR assay were considered HPV-52 positive.
PGMY-LB. HPV DNA was amplified with the L1 consensus HPV PGMY09/PGMY11 primer set, as previously described (13). The amplification mixture contained 4 mM MgCl2, 50 mM KCl, 7.5 units of AmpliTaq Gold DNA polymerase (Perkin-Elmer, Foster City, CA), a 200 µM concentration (each) of dATP, dCTP, and dGTP, 600 µM of dUTP, 100 pmol of each biotinylated PGMY primer, and 2.5 pmol each of the 5'-biotinylated ß-globin primers GH20 and PC04. HPV was amplified in a TC9600 thermal cycler at 95°C for 9 min, followed by denaturation for 1 min at 95°C, annealing for 1 min at 55°C, and extension at 72°C for 1 min for a total of 40 cycles. Amplification was followed by a 5-minute terminal extension step at 72°C. HPV genotyping was performed with a reverse line blot detection system as previously described (14). PCR products were denatured in 0.4 N NaOH and hybridized to an immobilized probe array containing probes for 37 mucosotropic HPV genotypes. The array was similar to that used with LA-HPV but contained an HPV-52-specific probe. Positive hybridization was detected by streptavidin-horseradish peroxidase-mediated color precipitation on the membrane at the probe line.
Real-time PCR assay for HPV-16. Each 20-µl reaction mixture contained 10 mM Tris-HCl, pH 8.0, 50 mM KCl, a 200 µM concentration (each) of dATP, dGTP, and dCTP, 400 µM dUTP, 0.05 µM of TaqMan probe HPV 16-TM, 0.3 pmol each of primers HPV 16-U and HPV 16-L (targeting the E6 gene), 3.0 mM MgCl2, and 5 units of AmpliTaq Gold DNA polymerase (15, 16). Capillaries were placed in a Light Cycler system (Roche Molecular Systems) and amplified at 95°C for 10 min, followed by 50 cycles at 95°C for 15 s and 55°C for 30 s. Ten copies of an HPV-16-expressing plasmid in 500 ng of cellular DNA served as a weak positive control.
Real-time PCR assay for HPV-52. Each 20-µl reaction mixture contained 10 mM Tris-HCl, pH 8.0, 50 mM KCl, a 200 µM concentration (each) of dATP, dGTP, and dCTP, 400 µM dUTP, 0.05 µM of TaqMan probe 52-TM (CGTGCAGGGTCCGGGGTC), 0.3 pmol each of primers 52JA-3 (GAACACAGTGTAGCTAACGCACG) and 52JA-4 (GCATGACGTTACACTTGGGTCA) (targeting the E6 gene), 2.0 mM MgCl2, and 5 units of AmpliTaq Gold DNA polymerase. The primers had been used for PCR-sequencing experiments in previous work (1). Capillaries were placed in a Light Cycler system and amplified at 95°C for 10 min, followed by 50 cycles at 95°C for 15 s and 60°C for 60 s. Ten copies of an HPV-52-expressing plasmid in 500 ng of cellular DNA served as a weak positive control. This assay was shown to be sensitive and specific for HPV-52 DNA detection (F. Coutlée, unpublished data).
Statistical methods. The crude percent agreement between both detection methods was the percentage of samples with identical results in both methods. Percentages of agreement for overall positivity (HPV DNA-positive samples), for positivity for high-risk HPV types as a group (types 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, and 82), and for positivity for each HPV type were calculated. Low-risk types were types 6, 11, 40, 42, 54, 61, 70, 72, 81, and CP6108, and types with unknown risk were types 55, 62, 64, 67, 69, 71, 73, 83, 84, and IS39 (HPV-82 subtype). The unweighted kappa statistic was calculated to adjust for chance agreement between HPV detection methods (11). In general, kappa values above 0.75 indicate excellent agreement, values between 0.40 and 0.75 indicate fair to good agreement, and values below 0.40 represent poor agreement beyond chance. The mean number of types detected per sample by each PCR test was compared using the sign test, since the frequencies of types per sample were not normally distributed. Two-sided McNemar's chi-square analysis for matched pair data was performed to analyze contingency tables comparing both PCR tests. Proportions were compared with the Z statistic.
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Clinical characteristics of 378 HIV-seropositive participants
|
|
View this table: [in a new window] |
TABLE 2. Comparison of PGMY-LB and LA-HPV assays for detection of HPV DNAs from 37 genotypes in 528 anogenital samples
|
Since these agreement calculations are influenced by the high rates of negative typing results in both tests, we compared the specific identification of individual genotypes by each of the two methods for all samples (Fig. 1). The mean agreement reached 97% ± 2.5% (95% CI, 95.8% to 98.5%) and ranged from 93.2% to 100%. The mean kappa value reached 0.86 ± 0.07 (95% CI, 0.83 to 0.88). Kappa values below 0.75 were obtained only for types 66 and 53. Since histological diagnosis was available only for men, we then compared agreements between tests, considering the AIN grades for the eight most frequent types (types 16, 18, 53, 58, 6, 42, 61, and 84). The AIN grade did not modify agreement between tests, as the mean agreement for men without disease was 94.6% ± 5.4% (kappa, 0.83 ± 0.13), that for men with AIN grade 1 was 94.3% ± 2.7% (kappa, 0.84 ± 0.07), and that for men with AIN grades 2 and 3 was 94.6% ± 3.4% (kappa, 0.86 ± 0.11). These differences were not significant (P > 0.10 for each comparison). HPV-67 was the only type for which PGMY-LB detected a greater number of samples than LA-HPV, with 25 samples being positive in both tests, 1 testing positive in LA-HPV only, and 3 testing positive in PGMY-LB only.
![]() View larger version (26K): [in a new window] |
FIG. 1. Agreement between results obtained for 528 anogenital samples with LA-HPV and PGMY-LB. Kappa coefficients are presented, with 95% CI.
|
We then determined if the use of LA-HPV over PGMY-LB could improve the type-specific detection rate for HPV infections (Fig. 2a, b, and c). The most frequent HPV type was HPV-16. For all but two types (67 and 71), the rate of detection was higher with LA-HPV. This difference reached statistical significance for types 16, 51, 52, 53, 66, and 61 as well as the high-risk types as a group (P < 0.05). More than one HPV type per sample was detected in 223 (94.5%) of 236 anal swab samples and 167 (57.2%) of 292 cervical or cervicovaginal swab samples (P < 0.001). The median numbers of HPV types per specimen detected in anal swab samples and cervical or cervicovaginal swabs with PGMY-LB were 5 (range, 0 to 18) and 1 (range, 0 to 12), respectively. Figure 3 demonstrates a strong correlation between the numbers of types per sample detected with LA-HPV and PGMY-LB. However, a greater number of types per sample was identified with LA-HPV (mean, 4.2 ± 3.4; 95% CI, 3.9 to 4.5; median, 3.0; range, 0 to 17) than with PGMY-LB (mean, 3.4 ± 3.0; 95% CI, 3.1 to 3.6; median, 3.0; range, 0 to 15) (P < 0.001). Figure 4 shows the distribution of the numbers of types identified per sample in excess with LA-HPV. Although nearly half of the samples contained the same number of types with both assays, the distribution of differences shows a shift towards a greater number of types per sample detected by LA-HPV.
![]() ![]() View larger version (38K): [in a new window] |
FIG.2. Detection rates for HPV types by LA-HPV and PGMY-LB. (a) High-risk types; (b) low-risk types; (c) types with unknown risk. Rates of detection were compared, and P values are shown at the bottom of each graph near the axis. Bars represent 95% CI.
|
![]() View larger version (16K): [in a new window] |
FIG. 3. Correlation between numbers of types detected in each sample by PGMY-LB and LA-HPV. The dashed lines represent the 95% CI of the regression line.
|
![]() View larger version (21K): [in a new window] |
FIG. 4. Differences in numbers of types detected per sample by LA-HPV and PGMY-LB. The number of types detected with PGMY-LB was subtracted from the number of types detected with LA-HPV for each sample. The percentage of the total number of samples is shown above each column.
|
|
|
|---|
In this evaluation, results obtained with LA-HPV were compared with those generated with PGMY-LB, a prototype assay that uses the same primers. In previous studies, PGMY-LB was shown to be a convenient, sensitive, and reproducible alternative to PCR assays based on radiolabeled probes (6, 7). Cycle sequencing has been reported to detect some HPV types better than PGMY-LB but did not perform as well on samples containing several HPV types (35). Moreover, PGMY-LB generally detected more HPV-positive samples than did cycle sequencing (35). One study reported that PGMY-LB performed similarly to the SPF10 Line Probe assay, a PCR-based system that also uses reverse hybridization for genotyping (34). An international proficiency study had also shown the reliability of PGMY-LB (22). We carried out the present study to assess the relative gain in diagnostic yield of using the commercial LA-HPV assay instead of PGMY-LB for the detection and typing of HPV DNA in 528 anogenital samples from HIV-seropositive individuals.
Based on these analyses, we found substantial agreement between the assays for the detection of HPV DNA. Our evaluation also demonstrated very good agreement between assays for consideration of each of the 37 genotypes individually. Our results indicate that HPV detection and typing can be significantly improved to various degrees for most genital types with the use of LA-HPV, including the most frequent genotype, HPV-16. Most samples positive for HPV-16 only with LA-HPV also tested positive with an HPV-16-specific real-time PCR assay, demonstrating a greater sensitivity of LA-HPV than of PGMY-LB. More HPV types per specimen were also identified with LA-HPV, especially with samples that contained over five genotypes.
The 93% to 100% agreement between the LA-HPV and PGMY-LB systems, whether considering all results or those for each of the 37 genotypes, is greater than the levels of agreement reported in the first evaluations of PGMY primers and in other studies comparing two consensus L1 PCR systems (4, 12, 13, 19, 27, 29, 32, 35). Since both PGMY systems use the same primer sets, a greater level of agreement was expected. Moreover, type-specific probes were identical between the two assays, except those for type 52. The high prevalence of HPV infection and the presence of multiple-type infections in our population allowed us to derive levels of agreement with relatively narrow 95% confidence intervals for most types studied. However, four types (HPV-82, -64, and -71 and IS39) were detected in <10 samples each. Since all individuals recruited for the anal cohort study had high-resolution anoscopies, we could assess if the correlation between assays was dependent on histological diagnosis. For this limited subset of samples, correlation was similar, irrespective of the grade of disease.
Several reasons could explain the increased ability of LA-HPV to detect HPVs compared with PGMY-LB. The oligonucleotide probes and consensus PGMY primers were identical for both systems, making it less likely that the excess detection rate for LA-HPV was due to nonspecific hybridization or amplification. Moreover, when samples positive for HPV-16 with LA-HPV only were further investigated with a real-time PCR assay, most were confirmed as positive for HPV-16 DNA. In contrast to PGMY-LB, the LA-HPV protocol uses standardized reagents that are quality controlled and cycling parameters that are optimized, along with an optimal concentration of ß-globin primers to minimize competition due to coamplification of ß-globin and HPV DNAs. Interestingly, previous runs using PGMY-LB without coamplification of ß-globin on the same samples confirmed the results obtained with LA-HPV for HPV-16 DNA in a substantial proportion of samples.
Coamplification of HPV with ß-globin could reduce the level of sensitivity of consensus L1 PCR assays for HPV detection, especially for multiple-type infections (7, 35). Moreover, all samples had tested positive initially for ß-globin in a PCR assay amplifying ß-globin separately from HPV DNA sequences (6, 7). Samples that tested negative for ß-globin in at least one PGMY assay contained HPV DNA. More samples were positive for ß-globin with LA-HPV. Since ß-globin is coamplified with HPV in PGMY assays, these assays could also be more sensitive to the effects of inhibitors than an assay testing only for ß-globin sequences with a higher primer concentration (5). This hypothesis could be investigated further with internal controls for ß-globin. Sample degradation could also have occurred since the initial testing for ß-globin. Nevertheless, more samples were considered adequate by testing positive for ß-globin with LA-HPV. Optimized amplification parameters could also have facilitated HPV typing for multiple-type infections, a frequent occurrence in samples from HIV-seropositive subjects.
Detection and genotyping of HPVs become more complex in samples containing multiple genotypes because of competition for reagents during amplification and the discrimination of types amplified by PCR. The correlation between the number of types contained in a sample and the number of additional types detected with LA-HPV suggests that less competition during amplification was encountered with LA-HPV than with PGMY-LB.
One limitation of the current study is the use of specimens from HIV-seropositive individuals. HIV-infected individuals have a high prevalence of HPV infection and are also infected more frequently with more than one HPV type. The test panel thus cannot be representative of the prevalence of HPV in a random population. On the other hand, our decision to use only samples from HIV-infected individuals afforded the opportunity to scrutinize assay performance under the more extreme conditions seen with specimens containing several HPV types. HIV-seropositive individuals are not only prone to acquiring multiple-type infections but also tend to harbor higher HPV viral loads (24). Another consideration may be that the specimens analyzed were stored for several months, and there could be some specimen degradation over time. The same sample preparations were evaluated in each assay concurrently, and degradation was thus not an issue here.
In conclusion, LA-HPV will be of great value for epidemiological studies and clinical trials to monitor HPV infection at the genotype level in genital samples. Since high-risk HPV persistence is the most important predictor of cervical cancer, genotyping assays could prove useful for assessing viral persistence, but further clinical studies are required before precise recommendations can be made. Eventually, women with persistent infections caused by the same types could be monitored more closely (10, 26). There was good agreement between these two assays for HPV DNA detection and HPV typing. Still, LA-HPV had a superior ability to detect HPV DNA and individual types compared with PGMY-LB. In light of the present results, studies currently using PGMY-LB will have to assess the opportunity to use LA-HPV because of the greater sensitivity of LA-HPV. Nevertheless, although there are some detection gains from using the LA-HPV commercial assay, the agreement with the prototype PGMY-LB assay is excellent, and therefore previous epidemiological studies using the prototype reagents are unlikely to suffer from severe misclassification bias. Further evaluations should be performed with HIV-seronegative subjects.
This work was supported by Roche Molecular Systems, which supplied reagents for PGMY assays, and by the Réseau FRSQ-SIDA Maladies Infectieuses. The National Cancer Institute of Canada supports the HIPVIRG cohort. The Canadian Institutes for Health Research and Health and Welfare Canada supported the Canadian Women's HIV Study. F.C. is a clinical research scholar supported by the Fonds de Recherche en Santé du Québec. E.F. holds a Distinguished Scientist Award from the Canadian Institutes for Health Research. S.W. holds career scientist salary support from the Ontario HIV Treatment Network.
The Canadian Women's HIV Study Group includes the following members: in Halifax, Janet Conners, Rob Grimshaw, David Haase, Lynn Johnston, Wally Schlech, and Arlo Yuzicappi-Fayant; in Hamilton, Stephen Landis and Fiona Smaill; in London, Tom Austin, Ole Hammerberg, and Ted Ralph; in Montréal, François Coutlée, Julian Falutz, Alex Ferenczy, Catherine Hankins, Marina Klein, Louise Labrecque, Richard Lalonde, John Macleod, Grégoire Noël, Chantal Perron, Jean-Pierre Routy, and Emil Toma; in Ottawa, Claire Touchie and Garry Victor; in Québec, Louise Coté, Hélène Senay, and Sylvie Trottier; in Saskatoon, Kurt Williams; in Sherbrooke, Alain Piché; in Sudbury, Roger Sandre; in Toronto, Louise Binder, Donna Keystone, Anne Phillips, Anita Rachlis, Irving Salit, Cheryl Wagner, and Sharon Walmsley; and in Vancouver, Paula Braitstein, David Burdge, Marianne Harris, Deborah Money, and Julio Montaner. ![]()
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»