Previous Article | Next Article ![]()
Journal of Clinical Microbiology, October 2007, p. 3404-3407, Vol. 45, No. 10
0095-1137/07/$08.00+0 doi:10.1128/JCM.00458-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

Bundeswehr Institute of Microbiology, Neuherbergstrasse 11, 80937 Munich, Germany,1 Groupe de Biotechnologie des Anticorps, Départment de Biologie des Agents Transmissibles, Centre de Recherches du Service de Santé des Armées, 24 Avenue des Maquis du Grésivaudan, P.O. Box 87, 38702 La Tronche, France,2 World Health Organization Collaborating Center for Plague, Insitut Pasteur de Madagascar, Route de l'Institut Pasteur, Ambatofotsikely-Avaradoha, P.O. Box 1274, Antananarivo 101, Madagascar,3 Friedrich Loeffler Institut, Naumburgerstrasse 96a, 07743 Jena, Germany4
Received 28 February 2007/ Returned for modification 11 April 2007/ Accepted 17 July 2007
|
|
|---|
|
|
|---|
In order to compare different immunological assay formats and to evaluate commercial products, we compared an in-house immunochromatographic test (ICT) with two rapid commercial assays, namely, Plague BioThreat Alert test strips (BTA; Tetracore, Gaithersburg, MD) and ABICAP columns (Senova, Jena, Germany). To represent ELISA, the standard immunological test, a commercial ELISA for the detection of the F1 capsular antigen of Y. pestis, as a soluble molecule and at the surfaces of suspicious bacteria, was chosen (Seramun, Dolgenbrodt, Germany). Additionally, we performed flow cytometry (FC) and immunofluorescence (IF) microscopy with antibodies directed against F1 to identify and directly visualize the bacteria, respectively.
The detection limit for F1 soluble protein was assessed for all assays (Table 1) in triplicate in phosphate-buffered saline (PBS) spiked with clinical samples, using serial dilutions of one batch of purified F1 (from Y. pestis strain EV76) purchased from the Russian State Research Centre of Applied Microbiology, Obolensk, Russia. The purity of the protein preparation was confirmed by gel electrophoresis followed by staining with Coomassie blue (6). Regarding detection of F1 at the surfaces of bacteria, it was considered that specificity was at least as important as sensitivity, as this detection is performed after an initial cultivation step. This specificity was evaluated utilizing a representative collection of Y. pestis strains, other Yersinia sp. isolates, and 34 clinically relevant bacterial species grown at 37°C (Table 2) at a fixed concentration. Briefly, material from bacterial colonies was resuspended in PBS and adjusted to an optical density at 600 nm (OD600) of 1.0, corresponding to 5 x 108 bacteria/ml. Inactivation of Y. pestis was performed by incubating bacteria in PBS containing 0.1% Tween 20 and 10% formalin for 1 h at room temperature with shaking at 150 rpm. Subsequently, the bacteria were washed twice in PBS containing 0.1% Tween 20 and again adjusted to an OD600 of 1.0. The detection limit for bacteria was determined using serial dilutions of Y. pestis strain EV76 grown at 37°C without inactivation. The number of CFU was assessed using a standard plating method and confirmed using the Yersinia pestis LightMix quantitative real-time PCR assay produced by TIBMOLBIOL (Berlin, Germany). We additionally evaluated ease of handling, costs, and time required to perform the assays (Table 1).
|
View this table: [in a new window] |
TABLE 1. Performance of immunoassays detecting the specific F1 capsular antigen for the identification of Yersinia pestis
|
|
View this table: [in a new window] |
TABLE 2. Specificities of immunoassays targeting F1 capsular antigen of Yersinia pestis
|
The BTA test strip produced by Tetracore (Gaithersburg, MD) is a lateral-flow assay intended for qualitative analysis of environmental samples in the field. The assay was performed and the results were interpreted according to the manufacturer's instructions. ABICAP columns (Senova, Jena, Germany) contain a filter coated with anti-Y. pestis F1 antibodies (G20; Squarix, Marl, Germany). The captured analyte is detected using the same antibody conjugated with PolyHRP40 (SDT, Baesweiler, Germany). The ABICAP system has the theoretical advantage that a large sample volume can be loaded upon the columns, resulting in an enrichment of the soluble analyte (2). Readers for the ABICAP tests (ca. $500) are optional but facilitate the quantification of signals obtained. The test was performed according to the manufacturer's instructions, using a reader. The commercial ELISA applied for the detection of F1 (Seramun, Dolgenbrodt, Germany) provided all necessary reagents and was performed according to the manufacturer's instructions. FC analysis was performed on a Cyflow FL instrument (Partec, Muenster, Germany). Approximately 106 bacteria were suspended in 50 µl PBS containing 1% bovine serum albumin and 0.05% sodium azide. The Oregon Green-labeled anti-F1 antibody G20 (Squarix, Marl, Germany) was added at a concentration of 10 µg/ml. For the generic detection of bacteria, propidium iodide was used at a final concentration of 10 µg/ml. After 15 min of incubation in the dark at room temperature, 950 µl of PBS was added and centrifuged for 10 min at 6,000 rpm in a microcentrifuge. The supernatant was discarded, and the pellet was resuspended in 1 ml PBS containing 1% bovine serum albumin and 0.05% sodium azide. Only Oregon Green and propidium iodide double-positive events were counted as Y. pestis bacteria. IF microscopy was performed using inactivated bacteria suspended in PBS at a concentration of approximately 107 bacteria/ml. Twenty microliters of this suspension was placed on a slide and dried for 1 h at room temperature. The sample was fixed with methanol for 5 min and incubated with 20 µl of the anti-F1 antibody G20 conjugated with Oregon Green (diluted 1:50 in PBS containing 10 µg/ml Evans Blue) for 30 min at 37°C. After three washing steps with PBS, the sample was dried and covered with an antifade reagent containing the DNA-staining dye DAPI (4',6'-diamidino-2-phenylindole). The sample was analyzed with a standard fluorescence microscope (Axio Star Plus; Zeiss, Germany).
The ABICAP test had the best detection limit in buffer (0.25 ng/ml), but the in-house ICT, which had a detection limit of 0.75 ng/ml in buffer, showed the best results with all clinical samples (sputum, serum, and urine), with a sensitivity of 3.3 ng/ml (Table 1). The ABICAP test sensitivity was 3.3 ng/ml for sputum, but only 30 ng/ml for serum and urine, a value sufficient in most cases for diagnosis with serum but not urine. The third hand-held test evaluated in this study, the commercially available BTA test, had a much lower sensitivity than those of the ICT and the ABICAP test, equal to 35 ng F1/ml in buffer. This sensitivity was not enhanced by using the optional strip reader (ca. $4,000) available from Tetracore (Gaithersburg, MD), and the BTA test strip was not evaluated further. ELISA, with a detection limit of 0.75 ng/ml in buffer, had the same sensitivity with sputum as the in-house ICT and the ABICAP test (3.3 ng/ml), but its sensitivity with serum and urine (10 ng/ml) was intermediate compared to those of the other two tests. It is notable that the detection limits of previously established immunochromatographic dipsticks are 0.5 ng/ml in buffer (3), and thus equivalent to that of our in-house ICT, and 2 to 4 ng/ml with clinical samples for ELISAs (1, 9, 11).
The order of the evaluated tests regarding their sensitivities for F1 detection at the surfaces of bacteria generally mirrored the order for soluble F1 detection, but differences between test sensitivities were far less marked, as the numbers of bacteria detected ranged from 3 x 103 (ICT) to 7 x 103 (BTA test) (Table 1). In particular, all tests gave a positive response when a colony was resuspended in 500 µl PBS. It is possible that the narrowing of the difference between tests for detecting the multiple copies of F1 at the surfaces of bacteria may be due to an avidity effect that would compensate for the intermediate-level affinity of the antibodies that could be utilized in the test that performed worst on soluble F1. Importantly, the specificity of all tests for Y. pestis detection was 100%, as they identified all Y. pestis isolates but detected no other bacteria (Table 2).
The ICT, BTA, and ABICAP tests are all simple to perform. The time required to obtain results was less than 25 minutes for the ICT and the BTA test and 45 minutes for the ABICAP test. The ICT was the most economical test, as it was produced in-house and no special equipment was required to perform the test. FC was the most expensive technique due to the equipment cost ($60,000), but reagent costs per assay were relatively low (ca. $1). FC offers the possibility of high-throughput analysis and multiplexing for different targets. The ELISA format allows for the automated, simultaneous assessment of many samples. IF microscopy is useful for small numbers of samples and when visualization of bacteria is desired.
Our results indicate that the in-house ICT is a rapid, reliable, and economical benchtop tool for the detection of F1 for the presumptive identification of Y. pestis bacteria. Therefore, this lateral-flow assay should be developed further as a product for diagnostic purposes. The other assays also proved to be specific and offered individual advantages for various applications.
Published ahead of print on 25 July 2007. ![]()
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»