Previous Article | Next Article ![]()
Journal of Clinical Microbiology, February 2007, p. 553-558, Vol. 45, No. 2
0095-1137/07/$08.00+0 doi:10.1128/JCM.00709-06
Copyright © 2007, American Society for Microbiology. All Rights Reserved.
Division of Gastroenterology, University of Michigan Medical Center, Ann Arbor, Michigan
Received 4 April 2006/ Returned for modification 14 June 2006/ Accepted 22 November 2006
|
|
|---|
|
|
|---|
The Amplicor assay is the most widely used commercial PCR assay for quantifying HBV DNA. The automated version, Cobas Amplicor HBV Monitor test, has a lower limit of detection of 60 IU/ml but a limited range of linearity, up to 38,000 IU/ml, based on the manufacturer's package insert. Given that many patients with chronic hepatitis B, particularly those who are hepatitis B e antigen (HBeAg) positive, have HBV DNA levels that are 109 IU/ml or higher, retesting serial dilutions up to 1:1,000,000 may be necessary. Thus, the possibility of errors in quantifying very high HBV DNA levels is tremendous. In addition, the Cobas Amplicor HBV Monitor test, like other conventional PCR assays, measures the amount of input DNA at the end of the amplification reaction and is, therefore, subject to errors caused by a "plateau" effect (3).
Various assays utilizing real-time PCR technology have been recently developed to quantify HBV DNA (1, 4, 18, 24, 26, 27). Real-time PCR technology is based on the evaluation of a threshold cycle when the amplification products are detected for the first time. It is more precise than conventional PCR because results are obtained when the PCR is still in the exponential phase (10, 11). Many real-time PCR HBV DNA assays were developed in-house and have not been standardized or validated (1, 4, 18, 27). The Cobas TaqMan HBV test, the most commonly used commercial real-time PCR HBV DNA assay, has a lower limit of detection of 6 IU/ml and a range of linearity up to 780,000,000 IU/ml, based on the manufacturer's brochure. This assay is fully automated and incorporates an internal quantification standard, but it is expensive (8, 23, 25).
There are eight recognized HBV genotypes, designated A to H, based on a nucleotide difference of >8% in whole-genome sequencing (2, 7). Discrepancies in quantifying the hepatitis C virus (HCV) RNA in samples from patients infected with various HCV genotypes have been reported (9, 17, 20, 22). Data for the performance of HBV DNA assays across HBV genotypes are scanty.
Here we describe the development and evaluation of a TaqMan-based real-time in-house PCR assay validated for HBV genotypes A through H. The lower limit of detection and the dynamic range of the assay were determined, and the performance results of this assay of clinical samples was compared to those of two commercially available assays, Cobas Amplicor HBV Monitor test and Cobas TaqMan HBV test.
|
|
|---|
The primers and a fluorogenic 5'-end nuclease probe (TaqMan) were selected from a highly conserved region of the S gene after careful analysis of 27 full-length HBV sequences belonging to genotypes A through H deposited in the GenBank database and synthesized and purified by Integrated DNA Technologies (Coralville, IA). Comparisons of the sequences of the primers and probe to consensus sequences of each genotype are shown in Fig. 1.
![]() View larger version (23K): [in a new window] |
FIG. 1. Comparison of real-time PCR TaqMan probe and primer sequences with GenBank database sequences for HBV genotypes (accession numbers X02763, X51970, and AF090842), B (accession numbers D00329, AF100309, AB033554, D00330, and AB073858), C (accession numbers X04615, AB014381, M12906, and AB033556), D (accession numbers X65259, M32138, X85254, and X02496), E (accession numbers X75657 and AB032431), F (accession numbers X69798, AB036910, and AF22396), G (accession numbers AF160501, AB064310, and AF405706), and H (accession numbers AY090454, AY090457, and AY090460).
|
Serial dilutions of the WHO standard, with concentrations ranging from 20 to 2.0 x 106 IU/ml, were tested with the real-time PCR assay to obtain a standard curve. Subsequently, serial dilutions of HBV S gene plasmid DNA from a genotype A sample with concentrations ranging from 2.0 x 102 to 2.0 x 105 IU/ml were calibrated against the WHO standard. Finally, serial dilutions of the WHO standard and S gene plasmids of HBV genotypes A through H with concentrations ranging from 2.0 x 102 to 2.0 x 107 IU/ml were tested in parallel with the real-time PCR assay to compare the amplification efficiencies across these genotypes.
Patients and serum samples. A total of 169 serum samples collected from patients with chronic HBV infection seen in the Liver Clinics at the University of Michigan Hospital were studied. These patients were participants in one of three studies: the natural history of chronic HBV infection, antiviral resistance surveillance, and prevention of recurrent HBV infection after liver transplantation. All three studies were approved by our institutional review board, and all patients provided written informed consent for sample collection. Sera were divided into aliquots and stored at 70°C until used.
HBV DNA quantification. All samples were tested using our in-house real-time PCR assay, without knowledge of the results of commercial assays. Each assay included the following: HBV S plasmid standards (genotype A, concentrations of 5 x 100 to 2.0 x 109 IU/ml), two human serum samples that had previously tested positive for HBV DNA using a Cobas Amplicor HBV Monitor test (positive controls), water, and two serum samples from healthy subjects who were HBsAg negative (negative controls).
All samples were also tested with a Cobas Amplicor HBV Monitor version 2 (Roche Molecular Diagnostics, Branchburg, NJ), which has a linear dynamic range from 60 to 38,000 IU/ml. All samples with values of
38,000 IU/ml were diluted 1:1,000 to 1:100,000 to obtain a valid result. Forty-nine samples collected between June and December 2005 were further tested using a Cobas TaqMan HBV test (Roche Molecular Diagnostics, Branchburg, NJ), which has a linear dynamic range from 6 to at least 780,000,000 IU/ml.
HBV genotyping. The HBV genotypes of samples with HBV DNA detectable by a Cobas Amplicor Monitor assay were determined using a line probe assay, INNO-LiPA HBV Genotyping (Innogenetics NV, Ghent, Belgium), as described previously (14).
Statistical analyses. iCycler iQ TM sequence detector software (version 3.0) (Bio-Rad Laboratories, Hercules, CA) was used to determine real-time PCR results. Precision was calculated with the use of JMP statistical software (SAS Institute, Cary, NC). Assay reproducibility was assessed by the coefficient of variation (CV). Pearson's correlation coefficient was used to assess the linear regression between the log-transformed values of HBV DNA using our in-house real-time PCR assay and Cobas Amplicor and Cobas TaqMan assays.
|
|
|---|
![]() View larger version (32K): [in a new window] |
FIG. 2. Calibration of the HBV genotype A plasmid DNA against that of the WHO HBV international standard. Amounts of WHO HBV standard used in each reaction were 20, 2 x 102, 2 x 103, 2 x 104, 2 x 105, and 2 x 106 IU/ml. (A) The threshold cycle was plotted against input HBV DNA concentrations (standard curve). (B) Standard curve obtained from serial dilutions of HBV genotype A plasmid: 5, 10, 20, 2 x 103, 2 x 105, 2 x 107, and 2 x 109 IU/ml.
|
The precision of our in-house real-time PCR assay was determined by assessing the intra- and interassay CV. For intraassay variability, serum samples from 12 patients with chronic HBV infection including virus genotypes A through H and two samples from healthy subjects who were HBsAg negative were tested in triplicate in the same assay. The mean CV was 0.082 (range, 0.051 to 0.099). For interassay variability, DNA was extracted from each of 10 serum samples on three separate occasions. Each DNA extract was tested in duplicate in three different PCR assays. The HBV DNA values were found to be normally distributed on a logarithmic scale. The mean CV for all 10 samples tested was 0.16 (range, 0.036 to 0.216).
To determine whether plasmid HBV DNA can be used as the standard for testing serum samples, we tested three dilutions of the WHO standard in human serum at concentrations of 3 x 106, 3 x 104, and 3 x 102 IU/ml, three serum samples from HBV patients that had the same HBV DNA concentrations based on Cobas Amplicor HBV Monitor test results, and three serum samples, which were spiked with the same concentrations of HBV genotype A plasmid DNA, from HBsAg-negative subjects. DNA was extracted and HBV DNA quantified with our in-house real-time PCR assay using HBV genotype A plasmid DNA as the standard. DNA extraction from serum samples versus that from plasmids had a negligible effect on the results.
To determine if our in-house real-time PCR assay is equally accurate in quantifying HBV genotypes A through H, HBV genotype A through H plasmid DNA at concentrations from 2 x 101 to 2.0 x 107 IU/reaction were coamplified with the WHO standard. Figure 3 shows that amplification efficiencies were comparable for these eight genotypes. We then tested 32 patient samples (HBV genotype A, 5 samples; B, 5 samples; C, 5 samples; D, 5 samples; E, 3 samples; F, 2 samples; G, 2 samples; and H, 1 sample) with our in-house real-time PCR assay using genotype A through D plasmids as standards. Figure 4 shows that the results of samples from all eight genotypes (A through H) were similar regardless of which genotype (A through D) plasmid was used as the standard. These results indicate that the genotype A plasmid can be used as the standard for testing patient samples with other HBV genotypes.
![]() View larger version (51K): [in a new window] |
FIG. 3. Coamplification of plasmids of HBV genotypes A through H and the WHO standard at dilutions of 20, 2 x 103, 2 x 105, and 2 x 107 IU/ml. Correlation coefficient, 0.995; PCR efficiency, 111.9%. Genotype A, azure; B, pink; C, crimson; D, blue; E, purple; F, yellow; G, red; H, grass green; WHO standard, green.
|
![]() View larger version (48K): [in a new window] |
FIG. 4. Comparison of HBV DNA levels of 32 serum samples with HBV genotypes A through H tested with our in-house real-time PCR assay using DNA from plasmids of HBV genotypes A through D as standards.
|
![]() View larger version (11K): [in a new window] |
FIG. 5. Correlation of HBV DNA values from 49 serum samples measured by our in-house real-time PCR assay and by the Cobas TaqMan HBV test.
|
![]() View larger version (12K): [in a new window] |
FIG. 6. Correlation of HBV DNA values of 169 serum samples measured by our in-house real-time PCR assay and by the Cobas Amplicor HBV Monitor test.
|
|
View this table: [in a new window] |
TABLE 1. Comparison of results of 169 serum samples tested by our in-house real-time PCR assay and the Cobas Amplicor HBV Monitor test
|
|
|
|---|
The availability of HBV DNA assays with an improved sensitivity and a wider dynamic range will improve our ability to assess viral response to antiviral therapy for chronic hepatitis B. One-step testing not only saves time but also eliminates the risk of errors introduced by the dilution process. The potential for errors when samples need to be diluted 100,000-fold or more is substantial. The tendency of the Cobas Amplicor HBV Monitor test to overestimate samples with high HBV DNA levels may explain why recent clinical trials of antiviral therapy for chronic hepatitis B reported baseline serum HBV DNA levels as high as 13 log10 IU/ml (13, 14). Falsely high pretreatment serum HBV DNA levels may inflate the potency of antiviral therapies.
A major problem with HBV DNA assays is the lack of standardization. This has prompted recommendations to standardize HBV DNA assays against WHO or other international standards and to express results in international units (IU). Our assay was initially standardized against the WHO international HBV DNA standard (NIBSC code 97/746; genotype A, serotype adw2). However, the WHO standard was available only in concentrations of up to 2.0 x 107 IU/ml; therefore, we calibrated it against an HBV genotype A plasmid, which was used to establish a standard dilution panel with concentrations of up to 2 x 109 IU/ml for testing clinical samples. We showed that similar results were obtained for plasmid DNA or negative serum spiked with plasmid DNA, indicating that plasmid DNA can be used as the standard for testing patient samples despite potential differences in DNA extraction. Furthermore, we demonstrated that results were similar when a panel of genotype A through H patient samples was tested using genotype A through D plasmids as standards, indicating that our genotype A plasmid can be used as a standard for serum samples from patients infected with various HBV genotypes.
Several studies in the 1990s reported that some PCR assays used to quantify HCV RNA do not have the same accuracy across all HCV genotypes (16-19). One study reported the validation of the Cobas TaqMan HBV test against plasmids of HBV genotypes A through G (12). In that study, 57 HBsAg-positive specimens were tested using both a Cobas TaqMan HBV test and a Cobas Amplicor HBV Monitor test and results correlated well, with an R2 of 0.9165, but it was observed that the Cobas Amplicor HBV Monitor test underestimated HBV DNA levels for four genotype F specimens.
Our assay has similar amplification efficiencies across all known HBV genotypes, including genotype H; and intra- and interassay variabilities were also comparable across these eight genotypes. Correlation between the results of our assay and those of the Cobas TaqMan HBV test was excellent for the genotypes tested (A, B, C, D, and F). Unfortunately, due to a limitation in sample availability, we were not able to compare these two assays for HBV genotypes E, G, and H samples. Likewise, the correlation between our assay and the Cobas Amplicor HBV Monitor test was excellent across genotypes A through H for samples with results that fall within the dynamic range of the Amplicor test. Of the seven genotype F samples tested with our assay and with the Cobas Amplicor HBV Monitor test, all seven had values within 0.5 log10 IU/ml in the two assays. Two of these samples were also tested with the Cobas TaqMan HBV test, and results were within 0.5 log10 IU/ml in all three assays.
There are limitations with our in-house assays. The lack of an internal control does not allow us to rule out false-negative results due to the presence of inhibitors to PCR amplification. The limit of detection and the upper limit of the dynamic range are approximates, as a lot more replicates and lot-to-lot testing would be necessary to verify these values. Sequence variations in the primer target and probe regions that are not present in the 27 sequences from our GenBank search can affect quantification accuracy. There are also multiple challenges in maintaining quality control, including the prevention of cross-contamination, the maintenance of a dilution panel calibrated against the WHO standard, and the validation of genotype independence as new genotypes and new variants within known genotypes are identified.
In summary, we have developed an in-house real-time PCR assay that is sensitive, has a wide dynamic range, and has comparable amplification efficiencies across all known HBV genotypes. Our assay results have excellent correlation with those of the Cobas TaqMan HBV test and the Cobas Amplicor HBV Monitor test, regardless of HBV genotypes. Further studies to test additional samples with more replicates to confirm the genotype independence of our assay of clinical samples are ongoing.
Published ahead of print on 20 December 2006. ![]()
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»