Previous Article | Next Article ![]()
Journal of Clinical Microbiology, November 2008, p. 3752-3758, Vol. 46, No. 11
0095-1137/08/$08.00+0 doi:10.1128/JCM.00377-08
Copyright © 2008, American Society for Microbiology. All Rights Reserved.

Centre de Recherche en Infectiologie de l'Université Laval, 2705 Boul. Laurier, Québec, Québec, Canada, G1V 4G2,1 Industrial Materials Institute, National Research Council of Canada, 75 de Mortagne, Boucherville, Québec, Canada, J4B 6Y42
Received 25 February 2008/ Returned for modification 1 July 2008/ Accepted 31 August 2008
|
|
|---|
|
|
|---|
Plastic material selection for DNA microarray hybridization, capture probe immobilization, and surface activation have been investigated previously (2, 4-6, 9, 10, 13, 19, 25). Most studies dealing with hybridization on plastic supports reported only data for the hybridization of DNA to target complementary oligonucleotides (4-6, 10, 13, 19, 25). Therefore, their usefulness for molecular diagnostic purposes, in which the target nucleic acids are mainly PCR-amplified genetic materials, has not been demonstrated.
PCR-amplified bacterial and human genomic DNAs have both been used in plastic microarray hybridizations (11, 15, 17, 22). However, these hybridizations were carried out using complex detection methods based on the use of radioactive isotopes, enzymatic assays, or biotin-labeled targets, which are incompatible with rapid and simple molecular diagnostics. Furthermore, these investigators have not reported any data on analytical sensitivity. Others have undertaken the chemical functionalization of plastics, allowing the use of fluorescently labeled amplicons. However, their detection technology using biochannel microarrays showed poor analytical sensitivities (approximately 10,000 PCR-amplified targets) (11).
We recently identified two suitable commercially available plastics, PMMA [poly(methylmethacrylate)]-VSUVT and Zeonor 1060R, and developed methods for surface chemistry and covalence immobilization of DNA oligonucleotides, allowing ultrasensitive detection of fluorescently labeled nucleic acid targets on plastic microarrays (2). Efficient chemical functionalization of plastic substrates for the immobilization of DNA probes was achieved.
In the present study, we have developed plastic supports for highly sensitive (
100 copies of PCR-amplified targets) DNA microarray hybridizations. The proof of concept of this plastic biochip technology was done through sensitive detection of several important human respiratory viral pathogens for molecular diagnostic purposes. The performance of hybridization with plastic supports made of PMMA-VSUVT or Zeonor 1060R was compared with that of high-quality glass-slide microarrays by using both passive and active (microfluidic) hybridization systems. This plastic microarray hybridization technology may be integrated into disposable microfluidic devices, thereby paving the way toward a fully integrated µ-TAS for sensitive nucleic acid detection.
|
|
|---|
Cloning of target genes and purification of RNA transcripts. For sensitivity assays, the target genes were cloned using the TOPO TA cloning system (Invitrogen, Burlington, Ontario, Canada) (Table 1). RNA transcription was performed using the Ampliscribe T7-Flash transcription kit (Epicentre, Madison, WI). The RNA transcripts were purified and quantified, and their quality was assessed, as described above for the viral RNA.
|
View this table: [in a new window] |
TABLE 1. Primers used to clone portions of the target genes from the four respiratory viruses
|
|
View this table: [in a new window] |
TABLE 2. RT-PCR primers used for multiplex amplification of the four respiratory viruses
|
|
View this table: [in a new window] |
TABLE 3. Capture probes for detection of the four respiratory viruses
|
Carboxylic acid groups were activated using a 0.417 M solution of 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and a 0.173 M solution of N-hydroxysuccinimide (NHS) in phosphate-buffered saline solution for 45 min prior to arraying with amino-modified probes. During the activation step, the carboxylic acids react with NHS to form the corresponding NHS esters, which in turn react efficiently with the amino groups from the DNA probes to form an amide linkage.
Microarray production and hybridization. Oligonucleotide capture probes (Table 3) targeting the four selected viruses were arrayed onto PMMA-VSUVT and Zeonor 1060R plastic slides as well as onto high-quality commercial glass slides (Aldehyde Plus arraying slides; Genetix, Boston, MA). Chemically activated plastic slides of PMMA-VSUVT and Zeonor 1060R were used to print the control and virus-specific capture probes. Oligonucleotide probe solutions at 60 µM in water were diluted twofold in Array-IT Micro Spotting Solution Plus (MSSP) (Telechem International, Sunnyvale, CA). Oligonucleotide probes were spotted onto both glass and plastic slides using a Virtek SDDC2 arrayer equipped with SMP2 pins (Telechem International, Sunnyvale, CA). After spotting, the slides were incubated at 23°C under 60% humidity for 4 h. The glass slides were subsequently washed for 5 min in a solution containing 0.2% NaBH4, 20% ethanol, 0.8% NaCl, 0.02% KCl, 0.144% Na2HPO4, and 0.024% KH2PO4 (pH 7.4). Plastic slides were washed in the same washing solution without NaBH4. Glass and plastic slides were both rinsed five times with ultrapure water.
Cy3-labeled RT-PCR amplicons (5 µl) were mixed with 15 µl of hybridization buffer (8.4% NaCl, 12.5% NaH2PO4·H2O, 3.0% EDTA, 0.04% polyvinylpyrrolidone, and 40% formamide). Passive hybridization was performed for 1 h at room temperature (23°C) by using 20-µl (15- by 13-mm) Hybri-well hybridization chambers (Sigma-Aldrich). Amplicons produced by RT-PCR were denatured by heating at 95°C for 5 min in hybridization buffer. The slides were subsequently washed with 0.2x SSPE (0.03 mol/liter NaCl, 2 mmol/liter NaH2PO4·H2O, 0.2 mmol/liter EDTA [pH 7.4]) containing 0.1% sodium dodecyl sulfate for 5 min and then rinsed with 0.2x SSPE for 5 min under continuous shaking (300 rpm).
Conditions for microfluidic flowthrough microarray hybridization using a compact-disk platform were those previously described (20) except that the hybridization time at room temperature was reduced from 5 to 3 min. Fluorescent images of all slides were obtained with a ScanArray 4000 XL microarray scanner (GSI Lumonics/Packard Biochips, Billerica, MA), and data were analyzed with GenePix Pro (version 6.0; MDS Analytical Technologies, Downingtown, PA). All microarray hybridization experiments were validated using an amino-modified 20-mer control oligonucleotide (A-S-bbc1 [5'-AGGATAGGCAGACCATACTC-3']) hybridized to a fully complementary Cy3-labeled 20-mer target oligonucleotide (C3-bbc1a [5'-Cy3-GAGTATGGTCTGCCTATCCT-3']). Arrays with a median signal of 5,000 fluorescence units or more for the control oligonucleotide were considered valid, while arrays with lower signals were discarded. All hybridization signals were corrected for background (the median background was 100 fluorescence units or fewer) and were then expressed as a percentage of the control oligonucleotide signal. This normalization allowed the removal of variations in fluorescence signal intensities resulting from potential slide-to-slide heterogeneity. Negative controls consisted of spotted MSSP.
Specificity tests with bacterial and human DNAs. Genomic DNA from Homo sapiens (Hsap-11) as well as from five common respiratory bacterial pathogens—Haemophilus influenzae (ATCC 9006), Streptococcus pneumoniae (ATCC 700673), Legionella pneumophila (ATCC 33152), Staphylococcus aureus (ATCC BAA-40), and Moraxella catarrhalis (ATCC 43628)—were used to test the specificities of the RT-PCR primers and capture probes by using the RT-PCR assay and the microarray hybridization procedure described above. Bacterial DNA was extracted using the Gnome DNA isolation kit (Qbiogene), while human DNA was isolated using the Magnesil KF genomic system (Promega, Madison, WI) on a KingFisher ML instrument (Thermo Scientific, Waltham, MA). Ten nanograms of purified bacterial or human genomic DNA per RT-PCR was used.
Stability tests for functionalized plastic slides. Zeonor 1060R slides were employed for testing the stabilities of the chemically activated plastic surfaces. The NHS esters can undergo hydrolysis, and therefore it is important to test their stability during storage. Freshly coated slides were stored in a desiccator for 2, 4, 6, 8, or 10 weeks prior to spotting with IAV capture probes and testing using passive microarray hybridization.
|
|
|---|
![]() View larger version (29K): [in a new window] |
FIG. 1. One-hour passive microarray hybridizations on PMMA-VSUVT, Zeonor 1060R, and glass supports. Target nucleic acids were amplicons generated by the respiratory-virus multiplex RT-PCR assay using 1,000 copies of purified RNA transcripts per reaction. The respective positions of the spotted virus-specific capture probes and oligonucleotide controls are given at the bottom. The PMT gains ranged from 72 to 75% for glass, from 70 to 76% for PMMA-VSUVT, and from 70 to 72% for Zeonor 1060R.
|
![]() View larger version (16K): [in a new window] |
FIG. 2. One-hour passive microarray hybridizations on PMMA-VSUVT, Zeonor 1060R, and glass supports using different RNA transcript concentrations. Fluorescent signals were obtained for the four respiratory viruses with 100, 500, and 1,000 copies of each viral RNA transcript per RT-PCR. Each fluorescence signal is the mean from separate hybridizations performed on two different slides printed with 24 spots of each capture probe and is expressed as a percentage of the signal with the hybridized control oligonucleotide. Error bars, standard deviations.
|
![]() View larger version (8K): [in a new window] |
FIG. 3. Ratios of the specific hybridization signal to the background for the three types of supports. Amplicons used for hybridization were generated with 100 copies of each target virus RNA transcript. Each hybridization signal-to-background ratio is the mean from separate hybridizations performed on two different slides printed with 24 spots of each capture probe compared to spotted MSSP (serving as the negative control). Error bars, standard deviations.
|
Microfluidic microarray hybridizations. Microfluidic microarray DNA hybridizations on the compact-disk platform using the plastic and glass supports showed that purified target viral RNAs for each of the four viruses were efficiently PCR amplified and detected by their specific capture probes. The hybridization signal intensities were comparable to those obtained under the passive hybridization conditions (Fig. 4 and 5). Normalized fluorescence signals with the microfluidic platform showed that the signal intensities obtained with PMMA-VSUVT slides were slightly stronger than those obtained with the Zeonor 1060R or glass slides (Fig. 5), as observed with passive hybridization experiments (Fig. 2).
![]() View larger version (35K): [in a new window] |
FIG. 4. Three-minute microfluidic flowthrough microarray hybridizations on PMMA-VSUVT, Zeonor 1060R, and glass supports. Target nucleic acids were amplicons generated by the multiplex RT-PCR assay from viral RNAs purified from cell culture supernatants for each of the four viruses. The respective positions of the spotted virus-specific capture probes and oligonucleotide controls are indicated on the right. Rows of spotted MSSP (negative control) between the virus-specific probes are indicated by open arrowheads (<). The PMT gains ranged from 67 to 75% for glass, from 73 to 78% for PMMA-VSUVT, and from 70 to 74% for Zeonor 1060R.
|
![]() View larger version (10K): [in a new window] |
FIG. 5. Histograms for microfluidic microarray hybridizations on PMMA-VSUVT, Zeonor 1060R, and glass supports. Each fluorescence signal is the mean from separate hybridizations performed on three different slides printed with 12 spots of each capture probe and is expressed as a percentage of the signal with the hybridized control oligonucleotide. Error bars, standard deviations.
|
![]() View larger version (7K): [in a new window] |
FIG. 6. Stability tests for activated Zeonor 1060R plastic slides. Freshly coated slides were stored in a desiccator for 2, 4, 6, 8, or 10 weeks prior to spotting with IAV capture probes and testing using passive microarray hybridization. The specific hybridization signal after 2 to 10 weeks of storage is expressed as a percentage of the hybridization signal measured with freshly coated slides. Error bars, standard deviations.
|
|
|
|---|
In this work, we report ultrasensitive microarray hybridization of fluorescently labeled PCR-amplified target DNA using two high-quality plastic substrates for molecular diagnostic purposes. Both plastics (PMMA-VSUVT and Zeonor 1060R) were previously selected for their premium optical properties and low autofluorescence background (2). They have been specifically functionalized in order to reduce background hybridization and increase specific hybridization signals. We observed that the hybridization background signals were as low as, or even lower than, those measured with commercially available high-quality functionalized microarray glass slides. The amplicons generated via multiplex RT-PCR from as few as 25 to 100 viral particles of IAV, EV, RSV, or MPV could be detected and discriminated, respectively, on plastic microarrays using either 1-h passive hybridization or 3-min microfluidic hybridization without any amplicon purification step. Specific fluorescence signals were nonambiguous and were as high as (Zeonor 1060R), or higher than (PMMA-VSUVT), those obtained with a glass substrate. Similar results were obtained using the microfluidic platform (20). To our knowledge, this is by far (at least 100-fold) the lowest detection limit achieved with DNA microarray hybridizations on plastic supports. Indeed, most published studies of microarray hybridizations on plastic supports did not report any analytical sensitivity data (2, 5, 6, 9, 10, 12, 13, 16-18, 22, 23). Lenigk et al. (11) have described microfluidic hybridization of PCR-amplified, Cy- labeled staphylococcal DNA onto a polycarbonate microarray, detecting a minimum of 10,000 genome copies. This analytical sensitivity may be insufficient for reliable detection of microbial pathogens, which can be found at lower clinically relevant loads. For example, infections associated with viral loads as low as 100 viruses per ml of respiratory tract sample may be encountered (1, 3). A highly sensitive hybridization on a plastic microarray using DNA capture probes spotted onto microfabricated micropillars has been described recently (19). In this system, the background fluorescence from the area surrounding the pillars is rejected through confocal detection. An excellent signal-to-background ratio was obtained for hybridizations using labeled and reverse-transcribed total human RNA, but the fabrication and functionalization of those micropillars are far more complex than those of flat plastic substrates such as those described in the present study.
High background fluorescence on plastic supports is often due to nonspecific adsorption of the labeled target onto the substrate (4, 13, 19). In the present study, we report high signal-to-background ratios. On average, these ratios reached 250 for hybridization using 5 nM labeled oligonucleotide and 137 for hybridization of nonpurified labeled amplicons generated from 100 viral genome copies. This means that the background fluorescence represents as little as 0.4% or 0.7% of the signal, respectively. By comparison, Fixe et al. (5), using 40 times more labeled oligonucleotides (0.2 µM) on PMMA slides, reported a signal-to-background ratio of 90.
We previously described a centrifuge-based microfluidic system for rapid and efficient microarray hybridization on standard glass slides (20). In the present study, we obtained high fluorescence signal intensities and low background with both plastic and glass slides using this 3-min microfluidic microarray hybridization system, in which hybridizations are performed at room temperature (23°C) using nonpurified PCR products. The only other reported study of room temperature hybridization on plastic supports was performed using a 16-h protocol, and the hybridization signal-to-background ratios obtained were low (approximately 10) (4). Others have performed hybridization experiments on plastic supports at 30 to 65°C, requiring special heating devices to carry out the hybridizations (5, 6, 15, 17, 23, 25). In addition, stability tests demonstrated that when stored in a vacuum desiccator, the chemically activated plastic slides were stable for at least 10 weeks.
In conclusion, we have developed two functionalized plastic supports (PMMA-VSUVT and Zeonor 1060R) that allow efficient DNA microarray hybridizations at room temperature, with signal-to-background ratios and analytical sensitivities comparable to those obtained with high-quality standard glass slides. These plastic supports, which were shown to be highly stable, have been validated for microbiological diagnostic applications with both passive hybridization and active hybridization in a microfluidic system. Considering that both plastics are suitable for low-cost fabrication, this plastic microarray technology is promising for the development of fully integrated medical diagnostic devices, such as portable µ-TASs.
We thank Xavier Bouhy for viral culture preparations and Marie-Jeanne Fiola for microarray printing.
Published ahead of print on 10 September 2008. ![]()
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»