Previous Article | Next Article ![]()
Journal of Clinical Microbiology, March 2008, p. 1098-1100, Vol. 46, No. 3
0095-1137/08/$08.00+0 doi:10.1128/JCM.01926-07
Copyright © 2008, American Society for Microbiology. All Rights Reserved.

Department of Laboratory Medicine, Yale New Haven Hospital, and Yale University School of Medicine, New Haven, Connecticut
Received 28 September 2007/ Returned for modification 5 December 2007/ Accepted 20 December 2007
|
|
|---|
|
|
|---|
Laboratory diagnosis of HMPV infection has been limited because of the difficulty in growing the virus and the lack of readily available diagnostic reagents. Isolation in conventional cell cultures can take 2 weeks or more, and cytopathic effects can be difficult to recognize. Shell vial centrifugation cultures can provide results within 2 days, but high-quality antibodies have not been commercially available (11). Thus, reverse transcription-PCR (RT-PCR) is the most widely reported test (9, 15).
Direct immunofluorescence (DFA) staining of clinical specimens, with results available within 2 to 4 h, is commonly used in clinical virology laboratories for the rapid diagnosis of respiratory viruses (9, 10, 15). In this study, we evaluated a commercial monoclonal antibody reagent to HMPV for its utility in the rapid diagnosis of HMPV infection (Light Diagnostics, Chemicon International [now part of Millipore], Temecula, CA).
Respiratory samples submitted to the Clinical Virology Laboratory for respiratory virus testing from February through May 2007, the peak HMPV season in Connecticut, were used (4). Cytospin-prepared slides were fixed in acetone and stained with SimulFluor respiratory screen reagent (Chemicon International, Temecula, CA) as previously described (10). Excess samples from children <5 years of age testing negative by the respiratory screen were selected. An extra slide was stained for HMPV on the day of receipt, prior to RT-PCR testing. Additional samples from older patients were included when HMPV testing was requested. HMPV DFA results were not reported, since the reagent was considered a developmental device at the time of the study. For RT-PCR, 200 µl was placed in lysis buffer and stored at –70°C until tested, usually within 1 to 7 days. RNA was extracted using the NucliSens EasyMag extraction system (bioMérieux, Durham, NC). The real-time TaqMan RT-PCR assay targeted the HMPV fusion protein gene as previously described (11).
Two hundred nasopharyngeal (NP) swabs (MicroTest M4 medium; Remel, Lenexa, KS) and 2 bronchoalveolar lavage samples were tested; 190 samples were from children less than 5 years old, 5 were from older children, and 7 were from adults. Forty-eight (23.8%) were positive for HMPV by RT-PCR, and 41 of these were positive for HMPV by cytospin-enhanced DFA (Table 1). Forty-two (87.5%) of the 48 positives were from children
2 years old. One adult on steroid therapy was positive by RT-PCR and DFA. One PCR-negative sample was read as showing one DFA-positive cell. On rereading, one DFA-positive cell was again observed; however, staining of a second slide from this sample was negative. For the purposes of the study, the RT-PCR result was considered the true result and the DFA result was considered false positive. Thus, DFA had a sensitivity of 85.4%, a specificity of 99.4%, a positive predictive value of 97.6%, and a negative predictive value of 95.7%. The differences between the results for cytospin-enhanced DFA and RT-PCR were not statistically significant (McNemar's test; P = 0.0771). DFA staining of respiratory epithelial cells was bright, speckled, and predominantly cytoplasmic, with essentially no background staining (Fig. 1). Due to the selection of samples that were respiratory screen DFA negative, the specificity of the Light Diagnostics HMPV reagent was not fully evaluated. However, three samples that were RSV positive and one that was influenza virus A positive by DFA were tested for HMPV, because HMPV was requested. All four were negative with the HMPV DFA reagent, and no nonspecific staining was observed.
|
View this table: [in a new window] |
TABLE 1. Comparison of Light Diagnostics HMPV direct immunofluorescence reagent and HMPV real-time TaqMan RT-PCRa
|
![]() View larger version (18K): [in a new window] |
FIG. 1. Examples of ciliated columnar respiratory epithelial cells from patients' samples stained with Light Diagnostics HMPV DFA reagent. Staining is bright, apple green, speckled, and predominantly cytoplasmic. Nonspecific background staining is negligible.
|
![]() View larger version (15K): [in a new window] |
FIG. 2. CT values according to HMPV DFA results for 48 samples positive by TaqMan RT-PCR. The 41 samples positive by HMPV DFA had a median (—) CT value of 26.53 (range, 19.13 to 35.81), whereas the 7 samples negative by HMPV DFA had a median (—) CT value of 36.18 (range, 31.55 to 39.23).
|
Our study is important because the reagent will be marketed commercially and thus available to any laboratory. The Light Diagnostics HMPV DFA reagent detected 41 (85.4%) of 48 RT-PCR-positive samples. The staff found the HMPV DFA reagent superior in readability to any of the respiratory DFA stains currently used in our laboratory. It is possible that the one DFA-positive/RT-PCR-negative sample may have been a true positive, since the other studies of DFA have found DFA-positive/PCR-negative samples (7, 8). True HMPV positives have been missed by RT-PCR when only one HMPV gene was targeted (1), as with our assay, or when amplification was inhibited. Although inhibition following EasyMag extraction is rare in our experience, nevertheless the presence of inhibitors was not excluded.
PCR assays are generally more sensitive than other methods for detection of viruses, can be automated, and are suitable for high-volume testing in reference laboratories. However, in the average hospital laboratory, molecular amplification tests are done at most once a day and usually only on weekdays or are sent to a reference laboratory. Similarly, in our laboratory, PCR for respiratory viruses is reserved for DFA-negative hospitalized patients, and if the sample is not received by 7:30 a.m., the PCR result is not reported until the following afternoon.
DFA is best suited for in-house testing, where testing can be performed on demand or batched and tested several times a day. In our experience, the use of cytospin-enhanced slides provides many fewer inadequate samples, better readability, and more-sensitive results than standard slide preparation, in which the cell suspension is pipetted onto a multiwelled slide (12). During the peak winter respiratory season, our laboratory performs 40 to 120 respiratory DFA screens a day, with a result reported within 2 h of sample receipt, 16 h a day, 7 days a week. Respiratory screen DFA in a single cell spot detects RSV, influenza viruses A and B, and parainfluenza viruses 1 to 3 with sensitivities of 95 to >100% of cell cultures. For adenovirus, however, DFA detects only about 70% of culture-positive samples (10). Even if used on a limited basis, with its high sensitivity and specificity, ability to multiplex, and rapid turnaround time, DFA still retains a clinical advantage over PCR as a first-line test. Nevertheless, DFA testing is manual and requires a committed, well-trained, expert staff and results are highly laboratory dependent.
In summary, 6 years after the first report of HMPV by van den Hoogen et al. (16), a high-quality DFA reagent has become commercially available. Incorporating these HMPV antibodies into antibody pools used to screen for multiple respiratory viruses will further facilitate detection of this common virus. The availability of a high-quality DFA antibody for rapid diagnosis of HMPV infection should be of significant benefit to clinical laboratories and the patients that they serve.
This study was supported in part by Millipore.
Published ahead of print on 9 January 2008. ![]()
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»