This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marley, E. F.
Right arrow Articles by Campos, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marley, E. F.
Right arrow Articles by Campos, J. M.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, 12 1995, 3191-3193, Vol 33, No. 12
Copyright © 1995 by the American Society for Microbiology. All rights reserved.

Evaluation of E-Test for determination of antimicrobial MICs for Pseudomonas aeruginosa isolates from cystic fibrosis patients

EF Marley, C Mohla and JM Campos
Department of Pathology, George Washington University Medical Center, Washington, DC 20037, USA.

We determined the E-Test and National Committee for Clinical Laboratory Standards standardized agar dilution MICs of ceftazidime, ciprofloxacin, piperacillin, and tobramycin for Pseudomonas aeruginosa during tests of 100 rough and mucoid P. aeruginosa isolates from cystic fibrosis patients. The levels of agreement (+/- 1 log2 dilution) between quantitative E-Test and agar dilution MIC results were 80, 97, 73, and 89% for ceftazidime, ciprofloxacin, piperacillin, and tobramycin, respectively. Comparison of the results after converting the MIC data to qualitative categories (susceptible, intermediate, and resistant) yielded levels of agreement of 84, 96, 88, and 93% for the same agents, respectively. Of the 39 qualitative discrepancies, 36 were minor and 3 were very major. We conclude that use of the E-Test is easier and more practical than use of the agar dilution method for most laboratories and that the E-Test furnishes results which are at least as accurate as those obtained by the agar dilution method. However, the higher cost of the E-Test method would likely discourage most laboratories from selecting it over disk diffusion for routine antimicrobial susceptibility testing of P. aeruginosa isolates from cystic fibrosis patients.


This article has been cited by other articles:

  • Pitt, T L, Sparrow, M, Warner, M, Stefanidou, M (2003). Survey of resistance of Pseudomonas aeruginosa from UK patients with cystic fibrosis to six commonly prescribed antimicrobial agents. Thorax 58: 794-796 [Abstract] [Full Text]  
  • Saiman, L., Burns, J. L., Whittier, S., Krzewinski, J., Marshall, S. A., Jones, R. N. (1999). Evaluation of Reference Dilution Test Methods for Antimicrobial Susceptibility Testing of Pseudomonas aeruginosa Strains Isolated from Patients with Cystic Fibrosis. J. Clin. Microbiol. 37: 2987-2991 [Abstract] [Full Text]  