This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zrein, M.
Right arrow Articles by Soufflet, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zrein, M.
Right arrow Articles by Soufflet, L.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, 03 1995, 525-527, Vol 33, No. 3
Copyright © 1995 by the American Society for Microbiology. All rights reserved.

Recombinant antigen-based enzyme immunoassay for screening of Treponema pallidum antibodies in blood bank routine

M Zrein, I Maure, F Boursier and L Soufflet
Diagast Laboratories, Lille, France.

This work reports a comparison of an enzyme immunoassay (EIA) using two major Treponema pallidum recombinant antigens with a T. pallidum hemagglutination (TPHA) assay and a nontreponemal Venereal Disease Reference Laboratory (VDRL) test. A total of 1,822 normal donor serum samples was tested for cardiolipin and T. pallidum antibodies, respectively, by the VDRL assay and EIA. Among these samples, 440 were further tested by TPHA technology. Four samples were found positive by EIA, while all were reported to be negative by both TPHA and VDRL routine assays. Subsequent testing of EIA-positive samples confirmed 100% (four of four samples) and 25% (one of four samples) positive results, respectively, by immunofluorescence assay and a Western blot (immunoblot) syphilis kit. The sensitivity of the recombinant EIA was estimated at virtually 100% with a reference panel of 50 syphilitic samples. According to this study, the newly developed EIA kit shows 100% sensitivity combined to a specificity greater than 99.8% for detecting treponemal immunoglobulin G antibodies in blood bank syphilis screening.


This article has been cited by other articles:

  • Zetola, N. M., Engelman, J., Jensen, T. P., Klausner, J. D. (2007). Syphilis in the United States: An Update for Clinicians With an Emphasis on HIV Coinfection. Mayo Clin Proc. 82: 1091-1102 [Abstract] [Full Text]  
  • Woznicova, V., Valisova, Z. (2007). Performance of CAPTIA SelectSyph-G Enzyme-Linked Immunosorbent Assay in Syphilis Testing of a High-Risk Population: Analysis of Discordant Results. J. Clin. Microbiol. 45: 1794-1797 [Abstract] [Full Text]  
  • Marangoni, A., Sambri, V., Accardo, S., Cavrini, F., D'Antuono, A., Moroni, A., Storni, E., Cevenini, R. (2005). Evaluation of LIAISON Treponema Screen, a Novel Recombinant Antigen-Based Chemiluminescence Immunoassay for Laboratory Diagnosis of Syphilis. CVI 12: 1231-1234 [Abstract] [Full Text]  
  • Schmidt, B. L. (2004). Evaluation of a New Particle Gel Immunoassay for Determination of Antibodies against Treponema pallidum. J. Clin. Microbiol. 42: 2833-2835 [Abstract] [Full Text]  
  • Van Voorhis, W. C., Barrett, L. K., Lukehart, S. A., Schmidt, B., Schriefer, M., Cameron, C. E. (2003). Serodiagnosis of Syphilis: Antibodies to Recombinant Tp0453, Tp92, and Gpd Proteins Are Sensitive and Specific Indicators of Infection by Treponema pallidum. J. Clin. Microbiol. 41: 3668-3674 [Abstract] [Full Text]  
  • Deka, R. K., Machius, M., Norgard, M. V., Tomchick, D. R. (2002). Crystal Structure of the 47-kDa Lipoprotein of Treponema pallidum Reveals a Novel Penicillin-binding Protein. J. Biol. Chem. 277: 41857-41864 [Abstract] [Full Text]  
  • Sambri, V., Marangoni, A., Eyer, C., Reichhuber, C., Soutschek, E., Negosanti, M., D'Antuono, A., Cevenini, R. (2001). Western Immunoblotting with Five Treponema pallidum Recombinant Antigens for Serologic Diagnosis of Syphilis. CVI 8: 534-539 [Abstract] [Full Text]  
  • Schmidt, B. L., Edjlalipour, M., Luger, A. (2000). Comparative Evaluation of Nine Different Enzyme-Linked Immunosorbent Assays for Determination of Antibodies against Treponema pallidum in Patients with Primary Syphilis. J. Clin. Microbiol. 38: 1279-1282 [Abstract] [Full Text]  
  • Ebel, A., Vanneste, L., Cardinaels, M., Sablon, E., Samson, I., De Bosschere, K., Hulstaert, F., Zrein, M. (2000). Validation of the INNO-LIA Syphilis Kit as a Confirmatory Assay for Treponema pallidum Antibodies. J. Clin. Microbiol. 38: 215-219 [Abstract] [Full Text]  
  • Halling, V. W., Jones, M. F., Bestrom, J. E., Wold, A. D., Rosenblatt, J. E., Smith, T. F., Cockerill, F. R. III (1999). Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing. J. Clin. Microbiol. 37: 3233-3234 [Abstract] [Full Text]  
  • Young, H., Moyes, A., Seagar, L., McMillan, A. (1998). Novel Recombinant-Antigen Enzyme Immunoassay for Serological Diagnosis of Syphilis. J. Clin. Microbiol. 36: 913-917 [Abstract] [Full Text]  
  • Ebel, A., Bachelart, L., Alonso, J.-M. (1998). Evaluation of a New Competitive Immunoassay (BioElisa Syphilis) for Screening for Treponema pallidum Antibodies at Various Stages of Syphilis. J. Clin. Microbiol. 36: 358-361 [Abstract] [Full Text]