This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Segondy, M.
Right arrow Articles by Montes, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Segondy, M.
Right arrow Articles by Montes, B.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, November 1998, p. 3372-3374, Vol. 36, No. 11
0095-1137/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.

Evaluation of the Nuclisens HIV-1 QT Assay for Quantitation of Human Immunodeficiency Virus Type 1 RNA Levels in Plasma

Michel Segondy,1,* Thoai-Duong Ly,2 Martine Lapeyre,2 and Brigitte Montes1

Laboratoire de Virologie, Centre Hospitalier Universitaire de Montpellier, Montpellier,1 and Institut Fournier, Paris,2 France

Received 20 March 1998/Accepted 10 August 1998

Nuclisens HIV-1 QT is a new version of the NASBA HIV-1 QT assay for quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in plasma. The specificity of this assay was 100% in one laboratory and 99%---with nonrepeatability of the initial false positive---in another. The test was linear between 2.0 and 6.0 log RNA copies per ml. According to the input HIV-1 RNA concentration, accuracy varied from -0.11 to +0.10 log RNA copy per ml and precision varied from 0.66 to 0.14 log RNA copy per ml. Reproducibility decreased when the HIV-1 RNA level was near the lower limit of quantitation of the test. HIV-1 RNA could be quantitated by Nuclisens HIV-1 QT in 36% (laboratory 1) and 24% (laboratory 2) of clinical samples with HIV-1 RNA levels lower than the lower limit of quantitation by NASBA HIV-1 QT. Nuclisens HIV-1 QT was not suitable for measurement of RNA from clade G and group O HIV-1 strains.


* Corresponding author. Mailing address: Laboratoire de Virologie, Hôpital Saint-Eloi, Centre Hospitalier Universitaire, 34295 Montpellier Cedex 5, France. Phone: (33) 467-337127. Fax: (33) 467-337623. E-mail: msegondy{at}worldnet.fr.


Journal of Clinical Microbiology, November 1998, p. 3372-3374, Vol. 36, No. 11
0095-1137/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Foulongne, V., Montes, B., Didelot-Rousseau, M.-N., Segondy, M. (2006). Comparison of the LCx Human Immunodeficiency Virus (HIV) RNA Quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan Assays for Quantitation of HIV Type 1 RNA in Plasma.. J. Clin. Microbiol. 44: 2963-2966 [Abstract] [Full Text]  
  • Swanson, P., de Mendoza, C., Joshi, Y., Golden, A., Hodinka, R. L., Soriano, V., Devare, S. G., Hackett, J. Jr. (2005). Impact of Human Immunodeficiency Virus Type 1 (HIV-1) Genetic Diversity on Performance of Four Commercial Viral Load Assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT. J. Clin. Microbiol. 43: 3860-3868 [Abstract] [Full Text]  
  • Antunes, R., Figueiredo, S., Bartolo, I., Pinheiro, M., Rosado, L., Soares, I., Lourenco, H., Taveira, N. (2003). Evaluation of the Clinical Sensitivities of Three Viral Load Assays with Plasma Samples from a Pediatric Population Predominantly Infected with Human Immunodeficiency Virus Type 1 Subtype G and BG Recombinant Forms. J. Clin. Microbiol. 41: 3361-3367 [Abstract] [Full Text]  
  • de Baar, M. P., van Dooren, M. W., de Rooij, E., Bakker, M., van Gemen, B., Goudsmit, J., de Ronde, A. (2001). Single Rapid Real-Time Monitored Isothermal RNA Amplification Assay for Quantification of Human Immunodeficiency Virus Type 1 Isolates from Groups M, N, and O. J. Clin. Microbiol. 39: 1378-1384 [Abstract] [Full Text]  
  • Tang, Y.-W., Huong, J. T.-J., Lloyd, R. M. Jr., Spearman, P., Haas, D. W. (2000). Comparison of Human Immunodeficiency Virus Type 1 RNA Sequence Heterogeneity in Cerebrospinal Fluid and Plasma. J. Clin. Microbiol. 38: 4637-4639 [Abstract] [Full Text]  
  • Murphy, D. G., Côté, L., Fauvel, M., René, P., Vincelette, J. (2000). Multicenter Comparison of Roche COBAS AMPLICOR MONITOR Version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex Version 3.0 for Quantification of Human Immunodeficiency Virus Type 1 RNA in Plasma. J. Clin. Microbiol. 38: 4034-4041 [Abstract] [Full Text]  
  • Zanchetta, N., Nardi, G., Tocalli, L., Drago, L., Bossi, C., Pulvirenti, F. R., Galli, C., Gismondo, M. R. (2000). Evaluation of the Abbott LCx HIV-1 RNA Quantitative, a New Assay for Quantitative Determination of Human Immunodeficiency Virus Type 1 RNA. J. Clin. Microbiol. 38: 3882-3886 [Abstract] [Full Text]  
  • Lerma, J. G. G., Soriano, V., Mas, A., Quiñones-Mateu, M. E., Arts, E. J., Heneine, W. (2000). Quantitation of Human Immunodeficiency Virus Type 1 Group O Load in Plasma by Measuring Reverse Transcriptase Activity. J. Clin. Microbiol. 38: 402-405 [Abstract] [Full Text]