Previous Article | Next Article 
Journal of Clinical Microbiology, September 1998, p. 2718-2722, Vol. 36, No. 9
0095-1137/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.
Comparison of the Binax Legionella Urinary Antigen
Enzyme Immunoassay (EIA) with the Biotest Legionella Urin
Antigen EIA for Detection of Legionella Antigen in both
Concentrated and Nonconcentrated Urine Samples
J. A.
Domínguez,*
N.
Galí,
P.
Pedroso,
A.
Fargas,
E.
Padilla,
J.
M.
Manterola, and
L.
Matas
Servei de Microbiologia, Hospital
Universitari Germans Trias i Pujol, Facultat de Medicina de la
Universitat Autònoma de Barcelona, Barcelona, Spain
Received 19 February 1998/Returned for modification 31 March
1998/Accepted 15 June 1998
We evaluated a newly commercial enzyme immunoassay (EIA) (Biotest
Legionella Urin Antigen EIA; Biotest AG, Dreieich, Germany) for detection of antigens of all Legionella pneumophila
serogroups with a relatively wide spectrum of cross-reactivity as well
as antigens of other Legionella spp. by comparing its
sensitivity and specificity with those of an EIA for detection of
L. pneumophila serogroup 1 antigen
(Legionella urinary antigen EIA; Binax, Portland, Maine).
Both tests were performed with both concentrated and nonconcentrated urine samples. We also evaluated the capabilities of both EIAs to detect extracted soluble antigens of American Type
Culture Collection (ATCC) Legionella strains
(L. pneumophila serogroups 1 to 14, L. bozemanii, and L. longbeachae). The sensitivity
of the Biotest EIA was 66.66% in nonconcentrated urine and 86.66% in
concentrated urine. The sensitivity of the Binax EIA was 63.76% and
88.88% in nonconcentrated and concentrated urine, respectively. The
specificity was 100% in nonconcentrated and concentrated urine for
both assays. The Binax EIA and Biotest EIA detected extracted soluble antigens of L. pneumophila serogroups 1 to 14 and L. bozemanii ATCC strains. The cross-reactions
observed with the Binax EIA were probably due to common epitopes
directly related to lipopolysaccharide. Further
studies are required to determine the usefulness of the Binax EIA
for detection of urinary antigens from
Legionella species and serogroups other than L. pneumophila serogroup 1. The Biotest EIA proved to
be as rapid, sensitive, and specific as the Binax EIA for the diagnosis
of legionellosis. Concentration of antigen present in urine
increased the sensitivities of both techniques with no reduction in
specificity.
*
Corresponding author. Mailing address: Servei de
Microbiologia, Hospital Universitari Germans Trias i Pujol, Ctra.
Canyet s/n, 08916 Badalona, Barcelona, Spain. Phone: 34-3-4651200, ext. 474. Fax: 34-3-4657019. E-mail:
jadoming{at}ns.hugtip.scs.es.
Journal of Clinical Microbiology, September 1998, p. 2718-2722, Vol. 36, No. 9
0095-1137/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.
This article has been cited by other articles:
-
Loens, K., Van Heirstraeten, L., Malhotra-Kumar, S., Goossens, H., Ieven, M.
(2009). Optimal Sampling Sites and Methods for Detection of Pathogens Possibly Causing Community-Acquired Lower Respiratory Tract Infections. J. Clin. Microbiol.
47: 21-31
[Full Text]
-
Diederen, B. M. W., Kluytmans, J. A. J. W., Vandenbroucke-Grauls, C. M., Peeters, M. F.
(2008). Utility of Real-Time PCR for Diagnosis of Legionnaires' Disease in Routine Clinical Practice. J. Clin. Microbiol.
46: 671-677
[Abstract]
[Full Text]
-
Diederen, B. M. W., Peeters, M. F.
(2006). Evaluation of Two New Immunochromatographic Assays (Rapid U Legionella Antigen Test and SD Bioline Legionella Antigen Test) for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine.. J. Clin. Microbiol.
44: 2991-2993
[Abstract]
[Full Text]
-
Yzerman, E. P. F., den Boer, J. W., Lettinga, K. D., Schel, A. J., Schellekens, J., Peeters, M.
(2006). Sensitivity of three serum antibody tests in a large outbreak of Legionnaires' disease in the Netherlands.. J Med Microbiol
55: 561-566
[Abstract]
[Full Text]
-
Woodhead, M., Blasi, F., Ewig, S., Huchon, G., Leven, M., Ortqvist, A., Schaberg, T., Torres, A., van der Heijden, G., Verheij, T. J. M.
(2005). Guidelines for the management of adult lower respiratory tract infections. Eur Respir J
26: 1138-1180
[Abstract]
[Full Text]
-
Dirven, K., Ieven, M., Peeters, M. F, van der Zee, A., De Schrijver, K., Goossens, H.
(2005). Comparison of three Legionella urinary antigen assays during an outbreak of legionellosis in Belgium. J Med Microbiol
54: 1213-1216
[Abstract]
[Full Text]
-
Raggam, R. B., Leitner, E., Berg, J., Muhlbauer, G., Marth, E., Kessler, H. H.
(2005). Single-Run, Parallel Detection of DNA from Three Pneumonia-Producing Bacteria by Real-Time Polymerase Chain Reaction. J. Mol. Diagn.
7: 133-138
[Abstract]
[Full Text]
-
Lindsay, D. S.J., Abraham, W. H., Findlay, W., Christie, P., Johnston, F., Edwards, G. F.S.
(2004). Laboratory diagnosis of legionnaires' disease due to Legionella pneumophila serogroup 1: comparison of phenotypic and genotypic methods. J Med Microbiol
53: 183-187
[Abstract]
[Full Text]
-
Guerrero, C., Toldos, C. M., Yague, G., Ramirez, C., Rodriguez, T., Segovia, M.
(2004). Comparison of Diagnostic Sensitivities of Three Assays (Bartels Enzyme Immunoassay [EIA], Biotest EIA, and Binax NOW Immunochromatographic Test) for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine. J. Clin. Microbiol.
42: 467-468
[Abstract]
[Full Text]
-
Templeton, K. E., Scheltinga, S. A., Sillekens, P., Crielaard, J. W., van Dam, A. P., Goossens, H., Claas, E. C. J.
(2003). Development and Clinical Evaluation of an Internally Controlled, Single-Tube Multiplex Real-Time PCR Assay for Detection of Legionella pneumophila and Other Legionella Species. J. Clin. Microbiol.
41: 4016-4021
[Abstract]
[Full Text]
-
Kim, M. J., Sohn, J. W., Park, D. W., Park, S. C., Chun, B. C.
(2003). Characterization of a Lipoprotein Common to Legionella Species as a Urinary Broad-Spectrum Antigen for Diagnosis of Legionnaires' Disease. J. Clin. Microbiol.
41: 2974-2979
[Abstract]
[Full Text]
-
Wilson, D. A., Yen-Lieberman, B., Reischl, U., Gordon, S. M., Procop, G. W.
(2003). Detection of Legionella pneumophila by Real-Time PCR for the mip Gene. J. Clin. Microbiol.
41: 3327-3330
[Abstract]
[Full Text]
-
Wattanathum, A., Chaoprasong, C., Nunthapisud, P., Chantaratchada, S., Limpairojn, N., Jatakanon, A., Chanthadisai, N.
(2003). Community-Acquired Pneumonia in Southeast Asia: The Microbial Differences Between Ambulatory and Hospitalized Patients. Chest
123: 1512-1519
[Abstract]
[Full Text]
-
Aoki, S., Hirakata, Y., Miyazaki, Y., Izumikawa, K., Yanagihara, K., Tomono, K., Yamada, Y., Tashiro, T., Kohno, S., Kamihira, S.
(2003). Detection of Legionella DNA by PCR of whole-blood samples in a mouse model. J Med Microbiol
52: 325-329
[Abstract]
[Full Text]
-
Marcos, M.A., Jimenez de Anta, M.T., de la Bellacasa, J.P., Gonzalez, J., Martinez, E., Garcia, E., Mensa, J., de Roux, A., Torres, A.
(2003). Rapid urinary antigen test for diagnosis of pneumococcal community-acquired pneumonia in adults. Eur Respir J
21: 209-214
[Abstract]
[Full Text]
-
Reischl, U., Linde, H.-J., Lehn, N., Landt, O., Barratt, K., Wellinghausen, N.
(2002). Direct Detection and Differentiation of Legionella spp. and Legionella pneumophila in Clinical Specimens by Dual-Color Real-Time PCR and Melting Curve Analysis. J. Clin. Microbiol.
40: 3814-3817
[Abstract]
[Full Text]
-
Yzerman, E. P. F., Boer, J. W. d., Lettinga, K. D., Schellekens, J., Dankert, J., Peeters, M.
(2002). Sensitivity of Three Urinary Antigen Tests Associated with Clinical Severity in a Large Outbreak of Legionnaires' Disease in The Netherlands. J. Clin. Microbiol.
40: 3232-3236
[Abstract]
[Full Text]
-
Fields, B. S., Benson, R. F., Besser, R. E.
(2002). Legionella and Legionnaires' Disease: 25 Years of Investigation. Clin. Microbiol. Rev.
15: 506-526
[Abstract]
[Full Text]
-
Hayden, R. T., Uhl, J. R., Qian, X., Hopkins, M. K., Aubry, M. C., Limper, A. H., Lloyd, R. V., Cockerill, F. R.
(2001). Direct Detection of Legionella Species from Bronchoalveolar Lavage and Open Lung Biopsy Specimens: Comparison of LightCycler PCR, In Situ Hybridization, Direct Fluorescence Antigen Detection, and Culture. J. Clin. Microbiol.
39: 2618-2626
[Abstract]
[Full Text]
-
HELBIG, J. H., ULDUM, S. A., LUCK, P. C., HARRISON, T. G.
(2001). Detection of Legionella pneumophila antigen in urine samples by the BinaxNOW immunochromatographic assay and comparison with both Binax Legionella Urinary Enzyme Immunoassay (EIA) and Biotest Legionella Urin Antigen EIA. J Med Microbiol
50: 509-516
[Abstract]
[Full Text]
-
Benson, R. F., Tang, P. W., Fields, B. S.
(2000). Evaluation of the Binax and Biotest Urinary Antigen Kits for Detection of Legionnaires' Disease Due to Multiple Serogroups and Species of Legionella. J. Clin. Microbiol.
38: 2763-2765
[Abstract]