Previous Article | Next Article 
Journal of Clinical Microbiology, March 1999, p. 721-723, Vol. 37, No. 3
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.
Sensitivity and Specificity of Dipstick Tests for
Rapid Diagnosis of Malaria in Nonimmune Travelers
T.
Jelinek,1,*
M. P.
Grobusch,2
S.
Schwenke,2
S.
Steidl,1
F.
von
Sonnenburg,1
H. D.
Nothdurft,1
E.
Klein,2 and
T.
Löscher1
Department of Infectious Diseases and
Tropical Medicine, University of Munich,
Munich,1 and
Medical Clinic
(Infectious Diseases), Charité/Campus Virchow Hospital,
Humboldt University, Berlin,2 Germany
Received 13 July 1998/Returned for modification 28 September
1998/Accepted 17 November 1998
Swift diagnosis of Plasmodium falciparum malaria in
areas where the disease is not endemic is frequently complicated by the lack of experience on the side of involved laboratory personal. Diagnostic tools based on the dipstick principle for the detection of
plasmodial histidine-rich protein 2 (HRP-2) and parasite-specific lactate dehydrogenase (pLDH), respectively, have become available for
the qualitative detection of P. falciparum malaria. In
order to evaluate two of the currently available assays, specimens from 231 patients were screened during a prospective multicenter study. Among the screened specimens, samples from 53 patients (22.9%) were
positive for P. falciparum malaria by microscopy and/or
PCR. While the test kit based on the detection of HRP-2 performed with a sensitivity of 92.5% and a specificity of 98.3%, the kit for the
detection of pLDH showed a sensitivity of 88.5% and a specificity of
99.4%. Dipstick tests have the potential of enhancing speed and
accuracy of the diagnosis of P. falciparum malaria,
especially if nonspecialized laboratories are involved.
*
Corresponding author. Mailing address: Department of
Infectious Diseases and Tropical Medicine, University of Munich,
Leopoldstr. 5, 80802 Munich, Germany. Phone: (49)-89-2180-3517. Fax:
(49)-89-33-61-12. E-mail: jelinek{at}lrz.uni-muenchen.de.
Journal of Clinical Microbiology, March 1999, p. 721-723, Vol. 37, No. 3
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.
This article has been cited by other articles:
-
Cheng, A., Bell, D.
(2006). Evidence Behind the WHO Guidelines: Hospital Care for Children: What is the Precision of Rapid Diagnostic Tests for Malaria?. J Trop Pediatr
52: 386-389
[Full Text]
-
Lee, N., Baker, J., Andrews, K. T., Gatton, M. L., Bell, D., Cheng, Q., McCarthy, J.
(2006). Effect of Sequence Variation in Plasmodium falciparum Histidine- Rich Protein 2 on Binding of Specific Monoclonal Antibodies: Implications for Rapid Diagnostic Tests for Malaria.. J. Clin. Microbiol.
44: 2773-2778
[Abstract]
[Full Text]
-
Marx, A., Pewsner, D., Egger, M., Nuesch, R., Bucher, H. C., Genton, B., Hatz, C., Juni, P.
(2005). Meta-Analysis: Accuracy of Rapid Tests for Malaria in Travelers Returning from Endemic Areas. ANN INTERN MED
142: 836-846
[Abstract]
[Full Text]
-
Forney, J. R., Wongsrichanalai, C., Magill, A. J., Craig, L. G., Sirichaisinthop, J., Bautista, C. T., Miller, R. S., Ockenhouse, C. F., Kester, K. E., Aronson, N. E., Andersen, E. M., Quino-Ascurra, H. A., Vidal, C., Moran, K. A., Murray, C. K., DeWitt, C. C., Heppner, D. G., Kain, K. C., Ballou, W. R., Gasser, R. A. Jr.
(2003). Devices for Rapid Diagnosis of Malaria: Evaluation of Prototype Assays That Detect Plasmodium falciparum Histidine-Rich Protein 2 and a Plasmodium vivax-Specific Antigen. J. Clin. Microbiol.
41: 2358-2366
[Abstract]
[Full Text]
-
Richardson, D. C., Ciach, M., Zhong, K. J. Y., Crandall, I., Kain, K. C.
(2002). Evaluation of the Makromed Dipstick Assay versus PCR for Diagnosis of Plasmodium falciparum Malaria in Returned Travelers. J. Clin. Microbiol.
40: 4528-4530
[Abstract]
[Full Text]
-
Playford, E. G., Walker, J.
(2002). Evaluation of the ICT Malaria P.f/P.v and the OptiMal Rapid Diagnostic Tests for Malaria in Febrile Returned Travellers. J. Clin. Microbiol.
40: 4166-4171
[Abstract]
[Full Text]
-
Moody, A.
(2002). Rapid Diagnostic Tests for Malaria Parasites. Clin. Microbiol. Rev.
15: 66-78
[Abstract]
[Full Text]
-
Forney, J. R., Magill, A. J., Wongsrichanalai, C., Sirichaisinthop, J., Bautista, C. T., Heppner, D. G., Miller, R. S., Ockenhouse, C. F., Gubanov, A., Shafer, R., DeWitt, C. C., Quino-Ascurra, H. A., Kester, K. E., Kain, K. C., Walsh, D. S., Ballou, W. R., Gasser, R. A. Jr.
(2001). Malaria Rapid Diagnostic Devices: Performance Characteristics of the ParaSight F Device Determined in a Multisite Field Study. J. Clin. Microbiol.