This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Erali, M.
Right arrow Articles by Hillyard, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Erali, M.
Right arrow Articles by Hillyard, D. R.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, March 1999, p. 792-795, Vol. 37, No. 3
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.

Evaluation of the Ultrasensitive Roche Amplicor HIV-1 Monitor Assay for Quantitation of Human Immunodeficiency Virus Type 1 RNA

Maria Erali1 and David R. Hillyard1,2,*

ARUP Institute for Clinical and Experimental Pathology,1 and the Department of Pathology, University of Utah Health Sciences Center,2 Salt Lake City, Utah 84108

Received 21 July 1998/Returned for modification 28 September 1998/Accepted 8 December 1998

The ultrasensitive Amplicor HIV-1 Monitor test (Roche Diagnostic Systems) was evaluated for precision, linearity, and sensitivity and was compared to the standard Amplicor assay. The ultrasensitive assay reliably quantified samples in the range from 50 to 50,000 human immunodeficiency virus type 1 RNA copies/ml with acceptable correlation with the standard Amplicor test.


* Corresponding author. Mailing address: ARUP Laboratories, 500 Chipeta Way, Salt Lake City, UT 84108. Phone: (801) 583-2787, ext. 2202. Fax: (801) 584-5207. E-mail: hillyadr{at}arup-lab.com.


Journal of Clinical Microbiology, March 1999, p. 792-795, Vol. 37, No. 3
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Foulongne, V., Montes, B., Didelot-Rousseau, M.-N., Segondy, M. (2006). Comparison of the LCx Human Immunodeficiency Virus (HIV) RNA Quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan Assays for Quantitation of HIV Type 1 RNA in Plasma.. J. Clin. Microbiol. 44: 2963-2966 [Abstract] [Full Text]  
  • Salimnia, H., Moore, E. C., Crane, L. R., MacArthur, R. D., Fairfax, M. R. (2005). Discordance between Viral Loads Determined by Roche COBAS AMPLICOR Human Immunodeficiency Virus Type 1 Monitor (Version 1.5) Standard and Ultrasensitive Assays Caused by Freezing Patient Plasma in Centrifuged Becton-Dickinson Vacutainer Brand Plasma Preparation Tubes. J. Clin. Microbiol. 43: 4635-4639 [Abstract] [Full Text]  
  • Sivapalasingam, S., Essajee, S., Nyambi, P. N., Itri, V., Hanna, B., Holzman, R., Valentine, F. (2005). Human Immunodeficiency Virus (HIV) Reverse Transcriptase Activity Correlates with HIV RNA Load: Implications for Resource-Limited Settings. J. Clin. Microbiol. 43: 3793-3796 [Abstract] [Full Text]  
  • Swanson, P., de Mendoza, C., Joshi, Y., Golden, A., Hodinka, R. L., Soriano, V., Devare, S. G., Hackett, J. Jr. (2005). Impact of Human Immunodeficiency Virus Type 1 (HIV-1) Genetic Diversity on Performance of Four Commercial Viral Load Assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT. J. Clin. Microbiol. 43: 3860-3868 [Abstract] [Full Text]  
  • Muller, Z., Stelzl, E., Bozic, M., Haas, J., Marth, E., Kessler, H. H. (2004). Evaluation of Automated Sample Preparation and Quantitative PCR LCx Assay for Determination of Human Immunodeficiency Virus Type 1 RNA. J. Clin. Microbiol. 42: 1439-1443 [Abstract] [Full Text]  
  • Holzl, G., Stocher, M., Leb, V., Stekel, H., Berg, J. (2003). Entirely Automated Quantification of Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Plasma by Using the Ultrasensitive COBAS AMPLICOR HIV-1 Monitor Test and RNA Purification on the MagNA Pure LC Instrument. J. Clin. Microbiol. 41: 1248-1251 [Abstract] [Full Text]  
  • de Baar, M. P., Timmermans, E. C., Bakker, M., de Rooij, E., van Gemen, B., Goudsmit, J. (2001). One-Tube Real-Time Isothermal Amplification Assay To Identify and Distinguish Human Immunodeficiency Virus Type 1 Subtypes A, B, and C and Circulating Recombinant Forms AE and AG. J. Clin. Microbiol. 39: 1895-1902 [Abstract] [Full Text]  
  • Swanson, P., Soriano, V., Devare, S. G., Hackett, J. Jr. (2001). Comparative Performance of Three Viral Load Assays on Human Immunodeficiency Virus Type 1 (HIV-1) Isolates Representing Group M (Subtypes A to G) and Group O: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR Version 1.5, and Quantiplex HIV-1 RNA Version 3.0. J. Clin. Microbiol. 39: 862-870 [Abstract] [Full Text]  
  • Brambilla, D. J., Granger, S., Jennings, C., Bremer, J. W. (2001). Multisite Comparison of Reproducibility and Recovery from the Standard and Ultrasensitive Roche AMPLICOR HIV-1 MONITOR Assays. J. Clin. Microbiol. 39: 1121-1123 [Abstract] [Full Text]  
  • Erice, A., Brambilla, D., Bremer, J., Jackson, J. B., Kokka, R., Yen-Lieberman, B., Coombs, R. W. (2000). Performance Characteristics of the QUANTIPLEX HIV-1 RNA 3.0 Assay for Detection and Quantitation of Human Immunodeficiency Virus Type 1 RNA in Plasma. J. Clin. Microbiol. 38: 2837-2845 [Abstract] [Full Text]  
  • Witt, D. J., Kemper, M., Stead, A., Ginocchio, C. C., Caliendo, A. M. (2000). Relationship of Incremental Specimen Volumes and Enhanced Detection of Human Immunodeficiency Virus Type 1 RNA with Nucleic Acid Amplification Technology. J. Clin. Microbiol. 38: 85-89 [Abstract] [Full Text]