This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fischer, M.
Right arrow Articles by Cone, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fischer, M.
Right arrow Articles by Cone, R. W.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, May 1999, p. 1260-1264, Vol. 37, No. 5
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.

Highly Sensitive Methods for Quantitation of Human Immunodeficiency Virus Type 1 RNA from Plasma, Cells, and Tissues

Marek Fischer,1,* Werner Huber,1,dagger Alex Kallivroussis,1 Peter Ott,2 Milos Opravil,1 Ruedi Lüthy,1,Dagger Rainer Weber,1 and Richard W. Cone1

Division of Infectious Diseases and Hospital Epidemiology, Department of Medicine,1 and Clinic for Ear, Nose and Throat Surgery,2 University Hospital Zurich, CH-8091 Zurich, Switzerland

Received 28 August 1998/Returned for modification 9 December 1998/Accepted 26 January 1999

Precise and sensitive quantitation of viral RNA in specimens from human immunodeficiency virus (HIV) type 1 (HIV-1)-infected individuals has become an indispensable tool for the monitoring of the efficacy of highly active antiretroviral combination therapy. The present report describes reproducible and efficient protocols with enhanced sensitivity for quantitation of HIV-1 RNA from plasma, peripheral blood mononuclear cells, and tissues with Qiagen silica columns for RNA purification combined with the Roche Amplicor HIV-1 Monitor test for quantitative reverse transcription-PCR (RT-PCR). Extraction of RNA from 0.5 ml of plasma resulted in the detection of fewer than 20 HIV RNA copies/ml of plasma, equivalent to the centrifugation-based boosted RT-PCR assay. Silica extraction of cellular RNA resulted in the detection of fewer than 3 HIV-1 RNA copies/µg of total RNA. These techniques facilitate direct comparisons of viral loads between liquid and cellular specimens. Application of these sensitive methods may improve the assessment of the response to new antiretroviral regimens.


* Corresponding author. Mailing address: University Hospital, Division of Infectious Diseases, Raemistrasse 100, CH-8091 Zurich, Switzerland. Phone: 41-1-255-3610. Fax: 41-1-255-3291. E-mail: inffia{at}usz.unizh.ch.

dagger Present address: Swiss Serum and Vaccine Institute Bern, CH-3001 Bern, Switzerland.

Dagger Present address: Carmenstrasse 23, CH-8032 Zurich, Switzerland.


Journal of Clinical Microbiology, May 1999, p. 1260-1264, Vol. 37, No. 5
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Joos, B., Trkola, A., Fischer, M., Kuster, H., Rusert, P., Leemann, C., Boni, J., Oxenius, A., Price, D. A., Phillips, R. E., Wong, J. K., Hirschel, B., Weber, R., Gunthard, H. F., the Swiss HIV Cohort Study, (2005). Low Human Immunodeficiency Virus Envelope Diversity Correlates with Low In Vitro Replication Capacity and Predicts Spontaneous Control of Plasma Viremia after Treatment Interruptions. J. Virol. 79: 9026-9037 [Abstract] [Full Text]  
  • Muller, Z., Stelzl, E., Bozic, M., Haas, J., Marth, E., Kessler, H. H. (2004). Evaluation of Automated Sample Preparation and Quantitative PCR LCx Assay for Determination of Human Immunodeficiency Virus Type 1 RNA. J. Clin. Microbiol. 42: 1439-1443 [Abstract] [Full Text]  
  • Holzl, G., Stocher, M., Leb, V., Stekel, H., Berg, J. (2003). Entirely Automated Quantification of Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Plasma by Using the Ultrasensitive COBAS AMPLICOR HIV-1 Monitor Test and RNA Purification on the MagNA Pure LC Instrument. J. Clin. Microbiol. 41: 1248-1251 [Abstract] [Full Text]  
  • Oxenius, A., McLean, A. R., Fischer, M., Price, D. A., Dawson, S. J., Hafner, R., Schneider, C., Joller, H., Hirschel, B., Phillips, R. E., Weber, R., Gunthard, H. F. (2002). Human Immunodeficiency Virus-Specific CD8+ T-Cell Responses Do Not Predict Viral Growth and Clearance Rates during Structured Intermittent Antiretroviral Therapy. J. Virol. 76: 10169-10176 [Abstract] [Full Text]  
  • Eiros, J. M., Labayru, C., Hernandez, B., Ortiz de Lejarazu, R., Rodriguez Torres, A. (2002). Comparative Study of Two Methods for RNA Extraction Prior to Detection of Resistance to Human Immunodeficiency Virus Type 1 with the Line Probe Assay. J. Clin. Microbiol. 40: 2257-2259 [Abstract] [Full Text]  
  • Espy, M. J., Rys, P. N., Wold, A. D., Uhl, J. R., Sloan, L. M., Jenkins, G. D., Ilstrup, D. M., Cockerill, F. R. III, Patel, R., Rosenblatt, J. E., Smith, T. F. (2001). Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods. J. Clin. Microbiol. 39: 2233-2236 [Abstract] [Full Text]  
  • Mouland, A. J., Mercier, J., Luo, M., Bernier, L., DesGroseillers, L., Cohen, E. A. (2000). The Double-Stranded RNA-Binding Protein Staufen Is Incorporated in Human Immunodeficiency Virus Type 1: Evidence for a Role in Genomic RNA Encapsidation. J. Virol. 74: 5441-5451 [Abstract] [Full Text]  
  • Kuster, H., Opravil, M., Ott, P., Schlaepfer, E., Fischer, M., Gunthard, H. F., Luthy, R., Weber, R., Cone, R. W. (2000). Treatment-Induced Decline of Human Immunodeficiency Virus-1 p24 and HIV-1 RNA in Lymphoid Tissue of Patients with Early Human Immunodeficiency Virus-1 Infection. Am. J. Pathol. 156: 1973-1986 [Abstract] [Full Text]