This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Noborg, U.
Right arrow Articles by Lindh, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Noborg, U.
Right arrow Articles by Lindh, M.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, September 1999, p. 2793-2797, Vol. 37, No. 9
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.

Automated Quantitative Analysis of Hepatitis B Virus DNA by Using the Cobas Amplicor HBV Monitor Test

Ulrika Noborg,1 Annkatrin Gusdal,1 Eva K. Pisa,2 Anders Hedrum,2 and Magnus Lindh1,*

Department of Clinical Virology, Göteborg University, Göteborg,1 and Sangtec Medical, Stockholm,2 Sweden

Received 21 January 1999/Returned for modification 16 April 1999/Accepted 15 June 1999

A highly sensitive method of quantitative analysis of hepatitis B virus (HBV) DNA in serum, the Cobas Amplicor HBV Monitor (Cobas-AM) test, was evaluated. Following a manual extraction of viral DNA, amplification, colorimetric detection, and quantitative determination are all automatically performed in the Cobas analyzer. Serially diluted samples with known HBV DNA concentrations were analyzed blindly. All samples with a virus concentration of 400 copies/ml and 83% of samples with a virus concentration of 100 copies/ml could be detected. A linear correlation between input HBV DNA and measured HBV DNA was seen in the range from 100 to 105 copies/ml. The mean coefficient of variation was 29.6% for all input levels and 18.9% for HBV DNA concentrations above 400 copies/ml. Samples with an HBV DNA level above 109 copies/ml could be reproducibly measured after predilution to 10-4 or 10-6 in negative serum; however, the level was underestimated if target DNA after dilution was still above the linear range of the assay. Quantitative results of the Cobas-AM test were interchangeable with measurements by the manual microwell plate version of Amplicor HBV Monitor (MWP-AM); the mean ratio for log Cobas-AM results/log MWP-AM results was 0.97 (standard error of the mean, 0.007) when serum samples from 153 chronic carriers were analyzed. The test should be of value for clinical assessment of chronic carriers and for monitoring the response to antiviral treatment. A limitation is the relatively narrow linear range of the assay, requiring predilution of high-titer (mainly hepatitis B e-antigen-positive) samples.


* Corresponding author. Mailing address: Department of Clinical Virology, Göteborg University, Guldhedsgatan 10B, 413 46 Göteborg, Sweden. Phone: 46 31 3424976. Fax: 46 31 827032. E-mail: magnus.lindh{at}microbio.gu.se.


Journal of Clinical Microbiology, September 1999, p. 2793-2797, Vol. 37, No. 9
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Liu, Y., Hussain, M., Wong, S., Fung, S. K., Yim, H. J., Lok, A. S. F. (2007). A Genotype-Independent Real-Time PCR Assay for Quantification of Hepatitis B Virus DNA. J. Clin. Microbiol. 45: 553-558 [Abstract] [Full Text]  
  • Liu, W.-C., Mizokami, M., Buti, M., Lindh, M., Young, K.-C., Sun, K.-T., Chi, Y.-C., Li, H.-H., Chang, T.-T. (2006). Simultaneous Quantification and Genotyping of Hepatitis B Virus for Genotypes A to G by Real-Time PCR and Two-Step Melting Curve Analysis. J. Clin. Microbiol. 44: 4491-4497 [Abstract] [Full Text]  
  • Laperche, S., Thibault, V., Bouchardeau, F., Alain, S., Castelain, S., Gassin, M., Gueudin, M., Halfon, P., Larrat, S., Lunel, F., Martinot-Peignoux, M., Mercier, B., Pawlotsky, J.-M., Pozzetto, B., Roque-Afonso, A.-M., Roudot-Thoraval, F., Saune, K., Lefrere, J.-J. (2006). Expertise of laboratories in viral load quantification, genotyping, and precore mutant determination for hepatitis B virus in a multicenter study.. J. Clin. Microbiol. 44: 3600-3607 [Abstract] [Full Text]  
  • Lindh, M., Hannoun, C., Malmstrom, S., Lindberg, J., Norkrans, G. (2006). Lamivudine Resistance of Hepatitis B Virus Masked by Coemergence of Mutations in Probe Region of the COBAS AMPLICOR Assay.. J. Clin. Microbiol. 44: 2587-2589 [Abstract] [Full Text]  
  • Lindh, M., Hannoun, C. (2005). Dynamic Range and Reproducibility of Hepatitis B Virus (HBV) DNA Detection and Quantification by Cobas Taqman HBV, a Real-Time Semiautomated Assay. J. Clin. Microbiol. 43: 4251-4254 [Abstract] [Full Text]  
  • Gordillo, R. M., Gutierrez, J., Casal, M. (2005). Evaluation of the COBAS TaqMan 48 Real-Time PCR System for Quantitation of Hepatitis B Virus DNA. J. Clin. Microbiol. 43: 3504-3507 [Abstract] [Full Text]  
  • Konnick, E. Q., Erali, M., Ashwood, E. R., Hillyard, D. R. (2005). Evaluation of the COBAS Amplicor HBV Monitor Assay and Comparison with the Ultrasensitive HBV Hybrid Capture 2 Assay for Quantification of Hepatitis B Virus DNA. J. Clin. Microbiol. 43: 596-603 [Abstract] [Full Text]  
  • Wong, D. K.-H., Yuen, M.-F., Tse, E., Yuan, H., Sum, S. S.-M., Hui, C.-K., Lai, C.-L. (2004). Detection of Intrahepatic Hepatitis B Virus DNA and Correlation with Hepatic Necroinflammation and Fibrosis. J. Clin. Microbiol. 42: 3920-3924 [Abstract] [Full Text]  
  • Yuan, H.-J., Yuen, M.-F., Wong, D. K.-H., Sum, S. S.-M., Lai, C.-L. (2004). Clinical Evaluation of the Digene Hybrid Capture II Test and the COBAS AMPLICOR Monitor Test for Determination of Hepatitis B Virus DNA Levels. J. Clin. Microbiol. 42: 3513-3517 [Abstract] [Full Text]  
  • Stelzl, E., Muller, Z., Marth, E., Kessler, H. H. (2004). Rapid Quantification of Hepatitis B Virus DNA by Automated Sample Preparation and Real-Time PCR. J. Clin. Microbiol. 42: 2445-2449 [Abstract] [Full Text]  
  • Leb, V., Stocher, M., Valentine-Thon, E., Holzl, G., Kessler, H., Stekel, H., Berg, J. (2004). Fully Automated, Internally Controlled Quantification of Hepatitis B Virus DNA by Real-Time PCR by Use of the MagNA Pure LC and LightCycler Instruments. J. Clin. Microbiol. 42: 585-590 [Abstract] [Full Text]  
  • Dai, C-Y, Yu, M-L, Chen, S-C, Lin, Z-Y, Hsieh, M-Y, Wang, L-Y, Tsai, J-F, Chuang, W-L, Chang, W-Y (2004). Clinical evaluation of the COBAS Amplicor HBV monitor test for measuring serum HBV DNA and comparison with the Quantiplex branched DNA signal amplification assay in Taiwan. J. Clin. Pathol. 57: 141-145 [Abstract] [Full Text]  
  • Kimura, T., Rokuhara, A., Matsumoto, A., Yagi, S., Tanaka, E., Kiyosawa, K., Maki, N. (2003). New Enzyme Immunoassay for Detection of Hepatitis B Virus Core Antigen (HBcAg) and Relation between Levels of HBcAg and HBV DNA. J. Clin. Microbiol. 41: 1901-1906 [Abstract] [Full Text]  
  • Ho, S. K.N., Yam, W.-C., Leung, E. T.K., Wong, L.-P., Leung, J. K.H., Lai, K.-N., Chan, T.-M. (2003). Rapid quantification of hepatitis B virus DNA by real-time PCR using fluorescent hybridization probes. J Med Microbiol 52: 397-402 [Abstract] [Full Text]  
  • Lopez, V. A., Bourne, E. J., Lutz, M. W., Condreay, L. D. (2002). Assessment of the COBAS Amplicor HBV Monitor Test for Quantitation of Serum Hepatitis B Virus DNA Levels. J. Clin. Microbiol. 40: 1972-1976 [Abstract] [Full Text]  
  • Kimura, T., Rokuhara, A., Sakamoto, Y., Yagi, S., Tanaka, E., Kiyosawa, K., Maki, N. (2002). Sensitive Enzyme Immunoassay for Hepatitis B Virus Core-Related Antigens and Their Correlation to Virus Load. J. Clin. Microbiol. 40: 439-445 [Abstract] [Full Text]  
  • Valentine-Thon, E., van Loon, A. M., Schirm, J., Reid, J., Klapper, P. E., Cleator, G. M. (2001). European Proficiency Testing Program for Molecular Detection and Quantitation of Hepatitis B Virus DNA. J. Clin. Microbiol. 39: 4407-4412 [Abstract] [Full Text]  
  • Whalley, S. A., Murray, J. M., Brown, D., Webster, G. J.M., Emery, V. C., Dusheiko, G. M., Perelson, A. S. (2001). Kinetics of Acute Hepatitis B Virus Infection in Humans. JEM 193: 847-854 [Abstract] [Full Text]  
  • Marin, I. J., Poljak, M., Seme, K., Meglic-Volkar, J., Maticic, M., Lesnicar, G., Brinovec, V. (2001). Comparative Evaluation of Semiautomated COBAS AMPLICOR Hepatitis B Virus (HBV) MONITOR Test and Manual Microwell Plate-Based AMPLICOR HBV MONITOR Test. J. Clin. Microbiol. 39: 758-761 [Abstract] [Full Text]  
  • Kessler, H. H., Stelzl, E., Daghofer, E., Santner, B. I., Marth, E., Lackner, H., Stauber, R. E. (2000). Semiautomated Quantification of Hepatitis B Virus DNA in a Routine Diagnostic Laboratory. CVI 7: 853-855 [Abstract] [Full Text]  
  • Pas, S. D., Fries, E., De Man, R. A., Osterhaus, A. D. M. E., Niesters, H. G. M. (2000). Development of a Quantitative Real-Time Detection Assay for Hepatitis B Virus DNA and Comparison with Two Commercial Assays. J. Clin. Microbiol. 38: 2897-2901 [Abstract] [Full Text]  
  • Niesters, H. G. M., Krajden, M., Cork, L., de Medina, M., Hill, M., Fries, E., Osterhaus, A. D. M. E. (2000). A Multicenter Study Evaluation of the Digene Hybrid Capture II Signal Amplification Technique for Detection of Hepatitis B Virus DNA in Serum Samples and Testing of EUROHEP Standards. J. Clin. Microbiol. 38: 2150-2155 [Abstract] [Full Text]  
  • Kessler, H. H., Preininger, S., Stelzl, E., Daghofer, E., Santner, B. I., Marth, E., Lackner, H., Stauber, R. E. (2000). Identification of Different States of Hepatitis B Virus Infection with a Quantitative PCR Assay. CVI 7: 298-300 [Abstract] [Full Text]