This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, S. C.
Right arrow Articles by Rosenstraus, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, S. C.
Right arrow Articles by Rosenstraus, M.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, November 2000, p. 4171-4179, Vol. 38, No. 11
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.

Improved Version 2.0 Qualitative and Quantitative AMPLICOR Reverse Transcription-PCR Tests for Hepatitis C Virus RNA: Calibration to International Units, Enhanced Genotype Reactivity, and Performance Characteristics

Sung C. Lee, Anisha Antony, Nitta Lee, Jeff Leibow, Jian Q. Yang, Stephen Soviero, Karen Gutekunst, and Maurice Rosenstraus*

Roche Molecular Systems, Inc., Pleasanton, California

Received 9 February 2000/Returned for modification 30 May 2000/Accepted 21 August 2000

Version 2.0 qualitative and quantitative AMPLICOR reverse transcription-PCR tests for HCV were designed to improve on the performance of first version of the hepatitis C virus (HCV) tests. The new tests were calibrated in international units, the new commonly accepted standard unit of measurement for HCV RNA. The sensitivity of the qualitative tests was enhanced by modifying the specimen processing procedure to achieve a limit of detection 50 IU/ml. The limit of detection for the quantitative tests was 600 IU/ml. Modifications to the amplification reaction mixture and thermal cycling conditions enabled all genotypes to be amplified with similar efficiency. The quantitative tests exhibited a linear range extending from 500 to 500,000 IU/ml and excellent reproducibility, with coefficients of variation ranging from 18 to 39%, within the linear range. These data indicate that the version 2.0 AMPLICOR HCV tests will improve diagnosis of HCV infection and will yield more-accurate titers for prognosis and for monitoring therapeutic efficacy, particularly at low viral loads. Furthermore, it will be possible to compare the performance characteristics and viral load measurements of AMPLICOR tests to those of other tests that adopt the international unit as the standard of measurement.


* Corresponding author. Present address: Roche Molecular Systems, 1080 Route 202, Somerville, NJ 08876. Phone: (908) 253-7463. Fax: (908) 253-3318. E-mail: maurice.rosenstraus{at}roche.com.


Journal of Clinical Microbiology, November 2000, p. 4171-4179, Vol. 38, No. 11
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Matsuura, K., Tanaka, Y., Hasegawa, I., Ohno, T., Tokuda, H., Kurbanov, F., Sugauchi, F., Nojiri, S., Joh, T., Mizokami, M. (2009). Abbott RealTime Hepatitis C Virus (HCV) and Roche Cobas AmpliPrep/Cobas TaqMan HCV Assays for Prediction of Sustained Virological Response to Pegylated Interferon and Ribavirin in Chronic Hepatitis C Patients. J. Clin. Microbiol. 47: 385-389 [Abstract] [Full Text]  
  • Colucci, G., Ferguson, J., Harkleroad, C., Lee, S., Romo, D., Soviero, S., Thompson, J., Velez, M., Wang, A., Miyahara, Y., Young, S., Sarrazin, C. (2007). Improved COBAS TaqMan Hepatitis C Virus Test (Version 2.0) for Use with the High Pure System: Enhanced Genotype Inclusivity and Performance Characteristics in a Multisite Study. J. Clin. Microbiol. 45: 3595-3600 [Abstract] [Full Text]  
  • Sabato, M. F., Shiffman, M. L., Langley, M. R., Wilkinson, D. S., Ferreira-Gonzalez, A. (2007). Comparison of Performance Characteristics of Three Real-Time Reverse Transcription-PCR Test Systems for Detection and Quantification of Hepatitis C Virus. J. Clin. Microbiol. 45: 2529-2536 [Abstract] [Full Text]  
  • Watson, J, Graves, S, Ferguson, J, D'Este, C, Batey, R (2007). Hepatitis C virus RNA quantitation and degradation studies in whole blood samples in vitro. Gut 56: 306-307 [Full Text]  
  • Sarrazin, C., Gartner, B. C., Sizmann, D., Babiel, R., Mihm, U., Hofmann, W. P., von Wagner, M., Zeuzem, S. (2006). Comparison of Conventional PCR with Real-Time PCR and Branched DNA-Based Assays for Hepatitis C Virus RNA Quantification and Clinical Significance for Genotypes 1 to 5.. J. Clin. Microbiol. 44: 729-737 [Abstract] [Full Text]  
  • Germer, J. J., Majewski, D. W., Yung, B., Mitchell, P. S., Yao, J. D. C. (2006). Evaluation of the Invader Assay for Genotyping Hepatitis C Virus. J. Clin. Microbiol. 44: 318-323 [Abstract] [Full Text]  
  • Antonishyn, N. A., Ast, V. M., McDonald, R. R., Chaudhary, R. K., Lin, L., Andonov, A. P., Horsman, G. B. (2005). Rapid Genotyping of Hepatitis C Virus by Primer-Specific Extension Analysis. J. Clin. Microbiol. 43: 5158-5163 [Abstract] [Full Text]  
  • Suzuki, T., Omata, K., Satoh, T., Miyasaka, T., Arai, C., Maeda, M., Matsuno, T., Miyamura, T. (2005). Quantitative Detection of Hepatitis C Virus (HCV) RNA in Saliva and Gingival Crevicular Fluid of HCV-Infected Patients. J. Clin. Microbiol. 43: 4413-4417 [Abstract] [Full Text]  
  • Schuurman, T., van Breda, A., de Boer, R., Kooistra-Smid, M., Beld, M., Savelkoul, P., Boom, R. (2005). Reduced PCR Sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit. J. Clin. Microbiol. 43: 4616-4622 [Abstract] [Full Text]  
  • Desombere, I., Van Vlierberghe, H., Couvent, S., Clinckspoor, F., Leroux-Roels, G. (2005). Comparison of Qualitative (COBAS AMPLICOR HCV 2.0 versus VERSANT HCV RNA) and Quantitative (COBAS AMPLICOR HCV Monitor 2.0 versus VERSANT HCV RNA 3.0) Assays for Hepatitis C Virus (HCV) RNA Detection and Quantification: Impact on Diagnosis and Treatment of HCV Infections. J. Clin. Microbiol. 43: 2590-2597 [Abstract] [Full Text]  
  • Gourlain, K., Soulier, A., Pellegrin, B., Bouvier-Alias, M., Hezode, C., Darthuy, F., Remire, J., Pawlotsky, J.-M., the DITTO Group, (2005). Dynamic Range of Hepatitis C Virus RNA Quantification with the Cobas Ampliprep-Cobas Amplicor HCV Monitor v2.0 Assay. J. Clin. Microbiol. 43: 1669-1673 [Abstract] [Full Text]  
  • Germer, J. J., Harmsen, W. S., Mandrekar, J. N., Mitchell, P. S., Yao, J. D. C. (2005). Evaluation of the COBAS TaqMan HCV Test with Automated Sample Processing Using the MagNA Pure LC Instrument. J. Clin. Microbiol. 43: 293-298 [Abstract] [Full Text]  
  • Margraf, R. L., Page, S., Erali, M., Wittwer, C. T. (2004). Single-Tube Method for Nucleic Acid Extraction, Amplification, Purification, and Sequencing. Clin. Chem. 50: 1755-1761 [Abstract] [Full Text]  
  • Krajden, M., Shivji, R., Gunadasa, K., Mak, A., McNabb, G., Friesenhahn, M., Hendricks, D., Comanor, L. (2004). Evaluation of the Core Antigen Assay as a Second-Line Supplemental Test for Diagnosis of Active Hepatitis C Virus Infection. J. Clin. Microbiol. 42: 4054-4059 [Abstract] [Full Text]  
  • Forman, M. S., Valsamakis, A. (2004). Verification of an Assay for Quantification of Hepatitis C Virus RNA by Use of an Analyte-Specific Reagent and Two Different Extraction Methods. J. Clin. Microbiol. 42: 3581-3588 [Abstract] [Full Text]  
  • Barbeau, J. M., Goforth, J., Caliendo, A. M., Nolte, F. S. (2004). Performance Characteristics of a Quantitative TaqMan Hepatitis C Virus RNA Analyte-Specific Reagent. J. Clin. Microbiol. 42: 3739-3746 [Abstract] [Full Text]  
  • Forman, M. S., Valsamakis, A. (2004). Increased Sensitivity of the Roche COBAS AMPLICOR HCV Test, Version 2.0, Using Modified Extraction Techniques. J. Mol. Diagn. 6: 225-230 [Abstract] [Full Text]  
  • Morishima, C., Chung, M., Ng, K. W., Brambilla, D. J., Gretch, D. R. (2004). Strengths and Limitations of Commercial Tests for Hepatitis C Virus RNA Quantification. J. Clin. Microbiol. 42: 421-425 [Abstract] [Full Text]  
  • Nolte, F. S., Green, A. M., Fiebelkorn, K. R., Caliendo, A. M., Sturchio, C., Grunwald, A., Healy, M. (2003). Clinical Evaluation of Two Methods for Genotyping Hepatitis C Virus Based on Analysis of the 5' Noncoding Region. J. Clin. Microbiol. 41: 1558-1564 [Abstract] [Full Text]  
  • Gorrin, G., Friesenhahn, M., Lin, P., Sanders, M., Pollner, R., Eguchi, B., Pham, J., Roma, G., Spidle, J., Nicol, S., Wong, C., Bhade, S., Comanor, L. (2003). Performance Evaluation of the VERSANT HCV RNA Qualitative Assay by Using Transcription-Mediated Amplification. J. Clin. Microbiol. 41: 310-317 [Abstract] [Full Text]  
  • Murray, K. F., Richardson, L. P., Morishima, C., Owens, J. W. M., Gretch, D. R. (2003). Prevalence of Hepatitis C Virus Infection and Risk Factors in an Incarcerated Juvenile Population: A Pilot Study. Pediatrics 111: 153-157 [Abstract] [Full Text]  
  • Richter, S. S. (2002). Laboratory Assays for Diagnosis and Management of Hepatitis C Virus Infection. J. Clin. Microbiol. 40: 4407-4412 [Full Text]  
  • Fiebelkorn, K. R., Lee, B. G., Hill, C. E., Caliendo, A. M., Nolte, F. S. (2002). Clinical Evaluation of an Automated Nucleic Acid Isolation System. Clin. Chem. 48: 1613-1615 [Full Text]  
  • Krajden, M., Ziermann, R., Khan, A., Mak, A., Leung, K., Hendricks, D., Comanor, L. (2002). Qualitative Detection of Hepatitis C Virus RNA: Comparison of Analytical Sensitivity, Clinical Performance, and Workflow of the Cobas Amplicor HCV Test Version 2.0 and the HCV RNA Transcription-Mediated Amplification Qualitative Assay. J. Clin. Microbiol. 40: 2903-2907 [Abstract] [Full Text]  
  • Giachetti, C., Linnen, J. M., Kolk, D. P., Dockter, J., Gillotte-Taylor, K., Park, M., Ho-Sing-Loy, M., McCormick, M. K., Mimms, L. T., McDonough, S. H. (2002). Highly Sensitive Multiplex Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA. J. Clin. Microbiol. 40: 2408-2419 [Abstract] [Full Text]  
  • Konnick, E. Q., Erali, M., Ashwood, E. R., Hillyard, D. R. (2002). Performance Characteristics of the COBAS Amplicor Hepatitis C Virus (HCV) Monitor, Version 2.0, International Unit Assay and the National Genetics Institute HCV Superquant Assay. J. Clin. Microbiol. 40: 768-773 [Abstract] [Full Text]  
  • Beld, M., Sentjens, R., Rebers, S., Weegink, C., Weel, J., Sol, C., Boom, R. (2002). Performance of the New Bayer VERSANT HCV RNA 3.0 Assay for Quantitation of Hepatitis C Virus RNA in Plasma and Serum: Conversion to International Units and Comparison with the Roche COBAS Amplicor HCV Monitor, Version 2.0, Assay. J. Clin. Microbiol. 40: 788-793 [Abstract] [Full Text]  
  • Germer, J. J., Heimgartner, P. J., Ilstrup, D. M., Harmsen, W. S., Jenkins, G. D., Patel, R. (2002). Comparative Evaluation of the VERSANT HCV RNA 3.0, QUANTIPLEX HCV RNA 2.0, and COBAS AMPLICOR HCV MONITOR Version 2.0 Assays for Quantification of Hepatitis C Virus RNA in Serum. J. Clin. Microbiol. 40: 495-500 [Abstract] [Full Text]  
  • Nolte, F. S., Fried, M. W., Shiffman, M. L., Ferreira-Gonzalez, A., Garrett, C. T., Schiff, E. R., Polyak, S. J., Gretch, D. R. (2001). Prospective Multicenter Clinical Evaluation of AMPLICOR and COBAS AMPLICOR Hepatitis C Virus Tests. J. Clin. Microbiol. 39: 4005-4012 [Abstract] [Full Text]  
  • Sarrazin, C., Hendricks, D. A., Sedarati, F., Zeuzem, S. (2001). Assessment, by Transcription-Mediated Amplification, of Virologic Response in Patients with Chronic Hepatitis C Virus Treated with Peginterferon {alpha}-2a. J. Clin. Microbiol. 39: 2850-2855 [Abstract] [Full Text]