This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martinot-Peignoux, M.
Right arrow Articles by Marcellin, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martinot-Peignoux, M.
Right arrow Articles by Marcellin, P.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, July 2000, p. 2722-2725, Vol. 38, No. 7
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.

Assessment of Viral Loads in Patients with Chronic Hepatitis C with AMPLICOR HCV MONITOR Version 1.0, COBAS HCV MONITOR Version 2.0, and QUANTIPLEX HCV RNA Version 2.0 Assays

Michéle Martinot-Peignoux,1,* Véronique Le Breton,1 Sandrine Fritsch,2 Gaëlle Le guludec,1 Nathalie Labouret,2 Françoise Keller,2 and Patrick Marcellin1

Unité de Recherche INSERM U481, Centre de Recherche Claude Bernard sur les Hépatites Virales and Service d'Hépatologie, Hôpital Beaujon, 92110 Clichy,1 and Institut de Virologie de la Faculté de Médecine, 67000 Strasbourg,2 France

Received 27 October 1999/Returned for modification 13 January 2000/Accepted 8 May 2000

The correlation between response to antiviral therapy and pretreatment viral load in patients with chronic hepatitis C has prompted the development of quantitative assays to measure viral load. The aim of our study was to assess the clinical relevance of the newly developed semiautomated PCR system COBAS HCV MONITOR version 2.0 in comparison with (i) the AMPLICOR HCV MONITOR version 1.0 assay, which underestimates RNA concentration of hepatitis C virus (HCV) genotypes 2 to 6, and (ii) the QUANTIPLEX HCV RNA version 2.0 assay, which achieves equivalent quantification for each HCV genotype, with samples from 174 patients diagnosed with chronic hepatitis C before therapy. The level and range of quantification measured with AMPLICOR HCV MONITOR version 1.0 were 1 log lower than when measured with the COBAS HCV MONITOR version 2.0, at 0.261 × 106 RNA copies/ml (range, 0.001 × 106 to 2.50 × 106 RNA copies/ml) and 4.032 × 106 RNA copies/ml (range, 0.026 × 106 to 72.6 × 106 RNA copies/ml), respectively. The two assays showed a poor correlation (r2 = 0.175). The level and range of quantification were similar when measured with the COBAS HCV MONITOR version 2.0 and QUANTIPLEX HCV RNA version 2.0 assays, at 3.03 × 106 RNA copies/ml (range, 0.023 × 106 to 72.6 × 106 RNA copies/ml) and 4.91 Meq/ml (range, 0.200 to 49.5 Meq/ml), respectively. The two assays showed a strong correlation (r2 = 0.686) for each HCV genotype. The duration of treatment (6 or 12 months) is modulated according to HCV genotype and viral load. Our results indicate that COBAS HCV MONITOR version 2.0 and QUANTIPLEX HCV RNA version 2.0 assays showing an equal dynamic range for each HCV genotype are suitable tools to assess patients before therapy.


* Corresponding author. Mailing address: INSERM U481, Hôpital Beaujon, 92118 Clichy-Cedex, France. Phone: 33 1 40 87 55 45. Fax: 33 1 47 30 94 40. E-mail: martinot{at}bichat.inserm.fr.


Journal of Clinical Microbiology, July 2000, p. 2722-2725, Vol. 38, No. 7
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Bartolome, J., Lopez-Alcorocho, J. M., Castillo, I., Rodriguez-Inigo, E., Quiroga, J. A., Palacios, R., Carreno, V. (2007). Ultracentrifugation of Serum Samples Allows Detection of Hepatitis C Virus RNA in Patients with Occult Hepatitis C. J. Virol. 81: 7710-7715 [Abstract] [Full Text]  
  • Germer, J. J., Heimgartner, P. J., Ilstrup, D. M., Harmsen, W. S., Jenkins, G. D., Patel, R. (2002). Comparative Evaluation of the VERSANT HCV RNA 3.0, QUANTIPLEX HCV RNA 2.0, and COBAS AMPLICOR HCV MONITOR Version 2.0 Assays for Quantification of Hepatitis C Virus RNA in Serum. J. Clin. Microbiol. 40: 495-500 [Abstract] [Full Text]