This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swenson, J. M.
Right arrow Articles by Tenover, F. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swenson, J. M.
Right arrow Articles by Tenover, F. C.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, October 2001, p. 3785-3788, Vol. 39, No. 10
0095-1137/01/$04.00+0   DOI: 10.1128/JCM.39.10.3785-3788.2001

Performance of Eight Methods, Including Two New Rapid Methods, for Detection of Oxacillin Resistance in a Challenge Set of Staphylococcus aureus Organisms

Jana M. Swenson,* Portia P. Williams, George Killgore, Caroline Mohr O'Hara, and Fred C. Tenover

Epidemiology and Laboratory Branch, Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, Atlanta, Georgia 30333

Received 2 May 2001/Returned for modification 8 June 2001/Accepted 25 July 2001

Using a set of 55 Staphylococcus aureus challenge organisms, we evaluated six routine methods (broth microdilution, disk diffusion, oxacillin agar screen, MicroScan conventional panels, MicroScan rapid panels, and Vitek cards) currently used in many clinical laboratories and two new rapid methods, Velogene and the MRSA-Screen, that require less than a day to determine the susceptibility of S. aureus to oxacillin. The methods were evaluated by using the presence of the mecA gene, as detected by PCR, as the "gold standard." The strains included 19 mecA-positive heterogeneously resistant strains of expression class 1 or 2 (demonstrating oxacillin MICs of 4 to >16 µg/ml) and 36 mecA-negative strains. The oxacillin MICs of the latter strains were 0.25 to 4 µg/ml when tested by broth microdilution with 2% NaCl-supplemented cation-adjusted Mueller-Hinton broth as specified by the NCCLS. However, when tested by agar dilution with 4% salt (the conditions used in the oxacillin agar screen method), the oxacillin MICs of 16 of the mecA-negative strains increased to 4 to 8 µg/ml. On initial testing, the percentages of correct results (% sensitivity/% specificity) were as follows: broth microdilution, 100/100; Velogene, 100/100; Vitek, 95/97; oxacillin agar screen, 90/92; disk diffusion, 100/89; MicroScan rapid panels, 90/86; MRSA-Screen, 90/100; and MicroScan conventional, 74/97. The MRSA-Screen sensitivity improved to 100% if agglutination reactions were read at 15 min. Repeat testing improved the performance of some but not all of the systems.


* Corresponding author. Mailing address: CDC, Mailstop G08, 1600 Clifton Rd., Atlanta, GA 30333. Phone: (404) 639-0196. Fax: (404) 639-1381. E-mail: jswenson{at}cdc.gov.


Journal of Clinical Microbiology, October 2001, p. 3785-3788, Vol. 39, No. 10
0095-1137/01/$04.00+0   DOI: 10.1128/JCM.39.10.3785-3788.2001



This article has been cited by other articles:

  • Bemis, D. A., Jones, R. D., Hiatt, L. E., Ofori, E. D., Rohrbach, B. W., Frank, L. A., Kania, S. A. (2006). Comparison of Tests To Detect Oxacillin Resistance in Staphylococcus intermedius, Staphylococcus schleiferi, and Staphylococcus aureus Isolates from Canine Hosts.. J. Clin. Microbiol. 44: 3374-3376 [Abstract] [Full Text]  
  • Bressler, A. M., Williams, T., Culler, E. E., Zhu, W., Lonsway, D., Patel, J. B., Nolte, F. S. (2005). Correlation of Penicillin Binding Protein 2a Detection with Oxacillin Resistance in Staphylococcus aureus and Discovery of a Novel Penicillin Binding Protein 2a Mutation. J. Clin. Microbiol. 43: 4541-4544 [Abstract] [Full Text]  
  • Swenson, J. M., Tenover, F. C., the Cefoxitin Disk Study Group, (2005). Results of Disk Diffusion Testing with Cefoxitin Correlate with Presence of mecA in Staphylococcus spp.. J. Clin. Microbiol. 43: 3818-3823 [Abstract] [Full Text]  
  • Velasco, D., del Mar Tomas, M., Cartelle, M., Beceiro, A., Perez, A., Molina, F., Moure, R., Villanueva, R., Bou, G. (2005). Evaluation of different methods for detecting methicillin (oxacillin) resistance in Staphylococcus aureus. J Antimicrob Chemother 55: 379-382 [Abstract] [Full Text]  
  • Caierao, J., Musskopf, M., Superti, S., Roesch, E., Dias, C. G, d'Azevedo, P. A (2004). Evaluation of phenotypic methods for methicillin resistance characterization in coagulase-negative staphylococci (CNS). J Med Microbiol 53: 1195-1199 [Abstract] [Full Text]  
  • Kipp, F., Becker, K., Peters, G., von Eiff, C. (2004). Evaluation of Different Methods To Detect Methicillin Resistance in Small-Colony Variants of Staphylococcus aureus. J. Clin. Microbiol. 42: 1277-1279 [Abstract] [Full Text]  
  • Skov, R., Smyth, R., Clausen, M., Larsen, A. R., Frimodt-Moller, N., Olsson-Liljequist, B., Kahlmeter, G. (2003). Evaluation of a cefoxitin 30 {micro}g disc on Iso-Sensitest agar for detection of methicillin-resistant Staphylococcus aureus. J Antimicrob Chemother 52: 204-207 [Abstract] [Full Text]  
  • Fahr, A.-M., Eigner, U., Armbrust, M., Caganic, A., Dettori, G., Chezzi, C., Bertoncini, L., Benecchi, M., Menozzi, M. G. (2003). Two-Center Collaborative Evaluation of the Performance of the BD Phoenix Automated Microbiology System for Identification and Antimicrobial Susceptibility Testing of Enterococcus spp. and Staphylococcus spp.. J. Clin. Microbiol. 41: 1135-1142 [Abstract] [Full Text]