This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Louro, A. P. S.
Right arrow Articles by Benjamin, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Louro, A. P. S.
Right arrow Articles by Benjamin, W. H., Jr.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, February 2001, p. 570-573, Vol. 39, No. 2
0095-1137/01/$04.00+0   DOI: 10.1128/JCM.39.2.570-573.2001
Copyright © 2001, American Society for Microbiology. All rights reserved.

Direct Identification of Mycobacterium avium Complex and Mycobacterium gordonae from MB/BacT Bottles Using AccuProbe

Ana Paula S. Louro,1 Ken B. Waites,1,2 Ecaterina Georgescu,1 and William H. Benjamin Jr.1,2,*

Departments of Pathology1 and Microbiology,2 University of Alabama at Birmingham, Birmingham, Alabama

Received 8 August 2000/Returned for modification 22 October 2000/Accepted 1 December 2000

We evaluated the ability of the AccuProbe (Gen-Probe, San Diego, Calif.) to detect Mycobacterium gordonae and Mycobacterium avium complex directly in liquid medium flagged positive by the MB/BacT (Organon Teknika Corp., Durham, N.C.). Seventy-one bottles from clinical specimens containing M. gordonae and 34 containing M. avium, confirmed by culture, were tested by direct AccuProbe assay for both organisms after additional incubation for >= 48 h and centrifugation at 4,500 × g for 15 min. Relative light unit (RLU) values were analyzed using the manufacturer's recommended cutoff of 30,000 RLU and a lower cutoff of 10,000 RLU. Using the 30,000 RLU cutoff, 55 of 71 (77.5%) specimens containing M. gordonae yielded positive results, whereas 28 of 34 (82.3%) M. avium complex specimens were correctly identified by direct probe. No specimens shown by culture to contain either M. gordonae or M. avium complex tested positive with the probe for the opposite organism (100% specificity). When the cutoff was lowered to 10,000 RLU, 67 of 71 M. gordonae (94.4%) and 32 of 34 M. avium complex (94.1%) specimens were correctly identified. This difference was significant for M. gordonae (P = 0.004) but not for M. avium complex (P = 0.26) compared to detection using the recommended RLU cutoff. Specificity was 100% for specimens containing M. gordonae that were tested with the M. avium complex probe using the 10,000 RLU cutoff, whereas specificity for specimens containing M. avium complex tested with the M. gordonae probe was 97%. Using a lower RLU cutoff for determining a positive result using the M. gordonae or M. avium complex probes when testing instrument-positive MB/BacT bottles directly will improve sensitivity without substantially compromising specificity.


* Corresponding author. Mailing address: Department of Pathology, WP 230, University of Alabama at Birmingham, 619 South 19th St., Birmingham, AL 35249-7331. Phone: (205) 934-6421. Fax: (205) 975-4468. E-mail: bbenjami{at}uab.edu.


Journal of Clinical Microbiology, February 2001, p. 570-573, Vol. 39, No. 2
0095-1137/01/$04.00+0   DOI: 10.1128/JCM.39.2.570-573.2001
Copyright © 2001, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Cloud, J. L., Carroll, K. C., Cohen, S., Anderson, C. M., Woods, G. L. (2005). Interpretive Criteria for Use of AccuProbe for Identification of Mycobacterium avium Complex Directly from 7H9 Broth Cultures. J. Clin. Microbiol. 43: 3474-3478 [Abstract] [Full Text]  
  • Lefmann, M., Honisch, C., Bocker, S., Storm, N., von Wintzingerode, F., Schlotelburg, C., Moter, A., van den Boom, D., Gobel, U. B. (2004). Novel Mass Spectrometry-Based Tool for Genotypic Identification of Mycobacteria. J. Clin. Microbiol. 42: 339-346 [Abstract] [Full Text]