Previous Article | Next Article 
Journal of Clinical Microbiology, April 2002, p. 1436-1440, Vol. 40, No. 4
0095-1137/02/$04.00+0 DOI: 10.1128/JCM.40.4.1436-1440.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
Rapid Detection of Shiga Toxin-Producing Bacteria in Feces by Multiplex PCR with Molecular Beacons on the Smart Cycler
Simon D. Bélanger,1,2 Maurice Boissinot,1,2 Christian Ménard,3 François J. Picard,1 and Michel G. Bergeron1,2*
Centre de Recherche en Infectiologie de l'Université Laval, Centre Hospitalier Universitaire de Québec (Pavillon Centre Hospitalier de l'Université Laval),1
Division de Microbiologie, Faculté de Médecine, Université Laval, Sainte-Foy, Québec, Canada G1V 4G2,2
Infectio Diagnostic (I.D.I.), Inc., Sainte-Foy, Québec, Canada G1V 2K82
Received 8 June 2001/
Returned for modification 8 August 2001/
Accepted 24 January 2002
We have developed a rapid (1-h) real-time fluorescence-based PCR assay with the Smart Cycler thermal cycler (Cepheid, Sunnyvale, Calif.) for the detection of Shiga toxin-producing Escherichia coli (STEC), as well as other Shiga toxin-producing bacteria. Based on multiple-sequence alignments, we have designed two pairs of PCR primers that efficiently amplify all variants of the Shiga toxin genes stx1 and stx2, respectively. These primer pairs were combined for use in a multiplex assay. Two molecular beacons bearing different fluorophores were used as internal probes specific for each amplicon. Assays performed with purified genomic DNA from a variety of STEC strains (n = 23) from diverse geographic locations showed analytical sensitivities of about 10 genome copies per PCR. Non-STEC strains (n = 20) were also tested, and no amplification was observed. The PCR results correlated perfectly with the phenotypic characterization of toxin production in both STEC and non-STEC strains, thereby confirming the specificity of the assay. The assay was validated by testing 38 fecal samples obtained from 27 patients. Of these samples, 26 were PCR positive for stx1 and/or stx2. Compared with the culture results, both the sensitivity and the negative predictive value were 100%. The specificity was 92%, and the positive predictive value was 96%. Moreover, this assay detected STEC from a sample in which the STEC concentration was at the limit of detection of the conventional culture methods and from a sample in which STEC was not detected by the conventional culture methods. This real-time PCR assay is simple, rapid, sensitive, and specific and allows detection of all Shiga toxin-producing bacteria directly from fecal samples, irrespective of their serotypes.
* Corresponding author. Mailing address: Centre de Recherche en Infectiologie de l'Université Laval, CHUQ (Pavillon CHUL), 2705 Boul. Laurier, Sainte-Foy, Québec, Canada G1V 4G2. Phone: (418) 654-2705. Fax: (418) 654-2715. E-mail:
Michel.G.Bergeron{at}crchul.ulaval.ca.
Journal of Clinical Microbiology, April 2002, p. 1436-1440, Vol. 40, No. 4
0095-1137/02/$04.00+0 DOI: 10.1128/JCM.40.4.1436-1440.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Gilmour, M. W., Chui, L., Chiu, T., Tracz, D. M., Hagedorn, K., Tschetter, L., Tabor, H., Ng, L. K., Louie, M.
(2009). Isolation and detection of Shiga toxin-producing Escherichia coli in clinical stool samples using conventional and molecular methods. J Med Microbiol
58: 905-911
[Abstract]
[Full Text]
-
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R. III, Smith, T. F.
(2006). Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing. Clin. Microbiol. Rev.
19: 165-256
[Abstract]
[Full Text]
-
Hsu, C.-F., Tsai, T.-Y., Pan, T.-M.
(2005). Use of the Duplex TaqMan PCR System for Detection of Shiga-Like Toxin-Producing Escherichia coli O157. J. Clin. Microbiol.
43: 2668-2673
[Abstract]
[Full Text]
-
Song, Y., Liu, C., Finegold, S. M.
(2004). Real-Time PCR Quantitation of Clostridia in Feces of Autistic Children. Appl. Environ. Microbiol.
70: 6459-6465
[Abstract]
[Full Text]
-
Sharkey, F. H., Banat, I. M., Marchant, R.
(2004). Detection and Quantification of Gene Expression in Environmental Bacteriology. Appl. Environ. Microbiol.
70: 3795-3806
[Full Text]
-
Kulesh, D. A., Baker, R. O., Loveless, B. M., Norwood, D., Zwiers, S. H., Mucker, E., Hartmann, C., Herrera, R., Miller, D., Christensen, D., Wasieloski, L. P. Jr., Huggins, J., Jahrling, P. B.
(2004). Smallpox and pan-Orthopox Virus Detection by Real-Time 3'-Minor Groove Binder TaqMan Assays on the Roche LightCycler and the Cepheid Smart Cycler Platforms. J. Clin. Microbiol.
42: 601-609
[Abstract]
[Full Text]
-
Kodaka, H., Uesaka, Y., Kashitani, F.
(2004). Nissui Glucose Fermentative Gram-Negative Rod Identification System EB-20 Gives a Unique Profile for Typical Non-Sorbitol-Fermenting Escherichia coli O157:H7. J. Clin. Microbiol.
42: 354-358
[Abstract]
[Full Text]
-
Jinneman, K. C., Yoshitomi, K. J., Weagant, S. D.
(2003). Multiplex Real-Time PCR Method To Identify Shiga Toxin Genes stx1 and stx2 and Escherichia coli O157:H7/H- Serotype. Appl. Environ. Microbiol.
69: 6327-6333
[Abstract]
[Full Text]
-
Belanger, S. D., Boissinot, M., Clairoux, N., Picard, Francois. J., Bergeron, M. G.
(2003). Rapid Detection of Clostridium difficile in Feces by Real-Time PCR. J. Clin. Microbiol.
41: 730-734
[Abstract]
[Full Text]