This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, B. G.
Right arrow Articles by Nolte, F. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, B. G.
Right arrow Articles by Nolte, F. S.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, May 2003, p. 2062-2067, Vol. 41, No. 5
0095-1137/03/$08.00+0     DOI: 10.1128/JCM.41.5.2062-2067.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.

Development and Verification of an Automated Sample Processing Protocol for Quantitation of Human Immunodeficiency Virus Type 1 RNA in Plasma

Brenda G. Lee,1 Kristin R. Fiebelkorn,2,{dagger} Angela M. Caliendo,2 and Frederick S. Nolte2*

Clinical Laboratories, Emory University Hospital,1 Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, Georgia2

Received 8 November 2002/ Returned for modification 30 December 2002/ Accepted 7 February 2003

We developed and verified an automated sample processing protocol for use with the AMPLICOR HIV-1 MONITOR test, version 1.5 (Roche Diagnostics, Indianapolis, Ind.). The automated method uses the MagNA Pure LC instrument and total nucleic acid reagents (Roche Applied Science, Indianapolis, Ind.) to extract human immunodeficiency virus type 1 (HIV-1) RNA from plasma specimens. We compared the HIV-1 load results for a dilution series (1 to 5 nominal log10 copies/ml) and 175 clinical specimens processed by the automated method to those for the same samples processed by the manual methods specified by the manufacturer. The sensitivity, dynamic range, and precision of the viral load assay obtained by automated processing of specimens were similar to those obtained by an ultrasensitive manual processing method. The results were highly correlated (R2, 0.95), and were in close agreement, with a mean difference of 0.09 log10 (standard deviation, 0.292). The limits of agreement were ±0.58 log10 for results for samples processed by both the manual and the automated methods. These performance characteristics were achieved with a smaller sample volume (200 versus 500 µl) and without a high-speed centrifugation step and required only 15 min of labor for a batch of 32 samples. In conclusion, the automated sample preparation protocol can replace both the standard and the ultrasensitive manual methods used with the AMPLICOR HIV-1 MONITOR test and can substantially reduce the labor associated with this test.


* Corresponding author. Mailing address: Clinical Laboratories, Emory University Hospital, Room F145, 1364 Clifton Rd. NE, Atlanta, GA 30322. Phone: (404) 712-7297. Fax: (404) 712-4632. E-mail: fnolte{at}emory.edu.

{dagger} Present address: Department of Pathology, University of Texas Health Science Center at San Antonio, San Antonio, Tex.


Journal of Clinical Microbiology, May 2003, p. 2062-2067, Vol. 41, No. 5
0095-1137/03/$08.00+0     DOI: 10.1128/JCM.41.5.2062-2067.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Yao, J. D. C., Germer, J. J., Damond, F., Roquebert, B., Descamps, D. (2008). Plasma Load Discrepancies between the Roche Cobas Amplicor Human Immunodeficiency Virus Type 1 (HIV-1) Monitor Version 1.5 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Assays. J. Clin. Microbiol. 46: 834-834 [Full Text]  
  • Loens, K., Bergs, K., Ursi, D., Goossens, H., Ieven, M. (2007). Evaluation of NucliSens easyMAG for Automated Nucleic Acid Extraction from Various Clinical Specimens. J. Clin. Microbiol. 45: 421-425 [Abstract] [Full Text]  
  • Schuurman, T., van Breda, A., de Boer, R., Kooistra-Smid, M., Beld, M., Savelkoul, P., Boom, R. (2005). Reduced PCR Sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit. J. Clin. Microbiol. 43: 4616-4622 [Abstract] [Full Text]  
  • Wilson, D., Yen-Lieberman, B., Reischl, U., Warshawsky, I., Procop, G. W. (2004). Comparison of Five Methods for Extraction of Legionella pneumophila from Respiratory Specimens. J. Clin. Microbiol. 42: 5913-5916 [Abstract] [Full Text]  
  • Hong, K. M., Najjar, H., Hawley, M., Press, R. D. (2004). Quantitative Real-Time PCR with Automated Sample Preparation for Diagnosis and Monitoring of Cytomegalovirus Infection in Bone Marrow Transplant Patients. Clin. Chem. 50: 846-856 [Abstract] [Full Text]