This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Horvath, L. L.
Right arrow Articles by Hospenthal, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Horvath, L. L.
Right arrow Articles by Hospenthal, D. R.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, January 2004, p. 115-118, Vol. 42, No. 1
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.1.115-118.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

Direct Comparison of the BACTEC 9240 and BacT/ALERT 3D Automated Blood Culture Systems for Candida Growth Detection

Lynn L. Horvath,1* Benjamin J. George,1 Clinton K. Murray,1 Linda S. Harrison,2 and Duane R. Hospenthal1

Department of Medicine,1 Department of Pathology and Area Laboratory Support, Brooke Army Medical Center, Fort Sam Houston, Texas2

Received 13 August 2003/ Returned for modification 20 September 2003/ Accepted 11 October 2003

A direct comparison of two automated blood culture systems was conducted to compare their ability to detect Candida growth. The systems evaluated were the BACTEC 9240 (Bactec) and BacT/ALERT 3D (BacT). The aerobic, anaerobic, and mycology media for each system were evaluated: Bactec Plus Aerobic/F, Plus Anaerobic/F, and Myco/F Lytic bottles,, respectively, and BacT FA, SN, and MB bottles, respectively. Each blood culture bottle was inoculated with fresh blood from healthy donors. Fifty isolates of Candida spp. were used. The six different blood culture bottles were each inoculated with 1,000 yeasts per bottle and then incubated in the corresponding automated system. The BacT detected growth of 90% (135 of 150) of Candida pathogens, while Bactec detected 66% (100 of 150). Growth was detected in all BacT and Bactec mycology bottles, all BacT aerobic bottles, and by terminal subculture of all bottles. Sixty-five of 300 (22%) bottles had no growth detected; 50 from the Bactec (5 aerobic and 45 anaerobic) and 15 from the BacT (all anaerobic). Terminal subculture of "negative" bottles demonstrated viable yeast growth from all 65 bottles, representing 65 false-negatives. The mean time to growth detection in the BacT system was 25.62 h while the Bactec was 27.30 h (P < 0.01). Both automated blood culture systems detected all episodes of simulated candidemia when specialized mycology media were used. However, when only standard aerobic and anaerobic media were used, the BacT performed better than the Bactec in overall growth detection, time to growth detection, and number of false-negatives.


* Corresponding author. Mailing address: Brooke Army Medical Center, Infectious Disease Service (MCHE-MDI), 3851 Roger Brooke Drive, Fort Sam Houston, TX 78234. Phone: (210) 916-4355. Fax: (210) 916-0388. E-mail: Lynn.Horvath{at}amedd.army.mil.


Journal of Clinical Microbiology, January 2004, p. 115-118, Vol. 42, No. 1
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.1.115-118.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Chiarini, A., Palmeri, A., Amato, T., Immordino, R., Distefano, S., Giammanco, A. (2008). Detection of Bacterial and Yeast Species with the Bactec 9120 Automated System with Routine Use of Aerobic, Anaerobic, and Fungal Media. J. Clin. Microbiol. 46: 4029-4033 [Abstract] [Full Text]  
  • Horvath, L. L., George, B. J., Hospenthal, D. R. (2007). Detection of Fifteen Species of Candida in an Automated Blood Culture System. J. Clin. Microbiol. 45: 3062-3064 [Abstract] [Full Text]  
  • Pfaller, M. A., Diekema, D. J. (2007). Epidemiology of Invasive Candidiasis: a Persistent Public Health Problem. Clin. Microbiol. Rev. 20: 133-163 [Abstract] [Full Text]  
  • Sandven, P., Bevanger, L., Digranes, A., Haukland, H. H., Mannsaker, T., Gaustad, P., the Norwegian Yeast Study Group, (2006). Candidemia in norway (1991 to 2003): results from a nationwide study.. J. Clin. Microbiol. 44: 1977-1981 [Abstract] [Full Text]  
  • George, B. J., Horvath, L. L., Hospenthal, D. R. (2005). Effect of Inoculum Size on Detection of Candida Growth by the BACTEC 9240 Automated Blood Culture System Using Aerobic and Anaerobic Media. J. Clin. Microbiol. 43: 433-435 [Abstract] [Full Text]  
  • Fricker-Hidalgo, H., Lebeau, B., Pelloux, H., Grillot, R., Horvath, L. L., Hospenthal, D. R. (2004). Use of the BACTEC 9240 System with Mycosis-IC/F Blood Culture Bottles for Detection of Fungemia. J. Clin. Microbiol. 42: 1855-1856 [Full Text]