Comparison of Five Methods for Extraction of Legionella pneumophila from Respiratory Specimens
Deborah Wilson,1
Belinda Yen-Lieberman,1
Udo Reischl,2
Ilka Warshawsky,3 and
Gary W. Procop1*
Sections of Clinical Microbiology,1
Molecular Pathology, Cleveland Clinic Foundation, Cleveland, Ohio,3
Institute of Medical Microbiology and Hygiene, University of Regensburg, Regensburg, Germany2
Received 18 December 2003/
Returned for modification 5 April 2004/
Accepted 17 August 2004
The efficiencies of five commercially available nucleic acid extraction methods were evaluated for the recovery of a standardized inoculum of Legionella pneumophila in respiratory specimens (sputum and bronchoalveolar lavage [BAL] specimens). The concentrations of Legionella DNA recovered from sputa with the automated MagNA Pure (526,200 CFU/ml) and NucliSens (171,800 CFU/ml) extractors were greater than those recovered with the manual methods (i.e., Roche High Pure kit [133,900 CFU/ml], QIAamp DNA Mini kit [46,380 CFU/ml], and ViralXpress kit [13,635 CFU/ml]). The rank order was the same for extracts from BAL specimens, except that for this specimen type the QIAamp DNA Mini kit recovered more than the Roche High Pure kit.
* Corresponding author. Mailing address: Section Head, Clinical Microbiology/L40, The Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH 44195. Phone: (216) 444-5879. Fax: (216) 445-6984. E-mail:
procopg{at}ccf.org.
Journal of Clinical Microbiology, December 2004, p. 5913-5916, Vol. 42, No. 12
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.12.5913-5916.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Dundas, N., Leos, N. K., Mitui, M., Revell, P., Rogers, B. B.
(2008). Comparison of Automated Nucleic Acid Extraction Methods with Manual Extraction. J. Mol. Diagn.
10: 311-316
[Abstract]
[Full Text]
-
Bastien, P., Procop, G. W., Reischl, U.
(2008). Quantitative Real-Time PCR Is Not More Sensitive than "Conventional" PCR. J. Clin. Microbiol.
46: 1897-1900
[Full Text]
-
Bencini, M. A., van den Brule, A. J. C., Claas, E. C. J., Hermans, M. H. A., Melchers, W. J. G., Noordhoek, G. T., Salimans, M. M. M., Schirm, J., Vink, C., van der Zee, A., Jansen, R.
(2007). Multicenter Comparison of Molecular Methods for Detection of Legionella spp. in Sputum Samples. J. Clin. Microbiol.
45: 3390-3392
[Abstract]
[Full Text]
-
Loens, K., Bergs, K., Ursi, D., Goossens, H., Ieven, M.
(2007). Evaluation of NucliSens easyMAG for Automated Nucleic Acid Extraction from Various Clinical Specimens. J. Clin. Microbiol.
45: 421-425
[Abstract]
[Full Text]
-
Diederen, B. M. W., de Jong, C. M. A., Marmouk, F., Kluytmans, J. A. J. W., Peeters, M. F., Van der Zee, A.
(2007). Evaluation of real-time PCR for the early detection of Legionella pneumophila DNA in serum samples. J Med Microbiol
56: 94-101
[Abstract]
[Full Text]
-
Procop, G. W.
(2006). Evaluation of Molecular Diagnostic Assays for Fungal Infections. J. Mol. Diagn.
8: 297-298
[Full Text]