This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chabbert, E.
Right arrow Articles by Bastien, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chabbert, E.
Right arrow Articles by Bastien, P.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, April 2004, p. 1719-1722, Vol. 42, No. 4
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.4.1719-1722.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

Comparison of Two Widely Used PCR Primer Systems for Detection of Toxoplasma in Amniotic Fluid, Blood, and Tissues

Elisabeth Chabbert,1 Laurence Lachaud,2 Lucien Crobu,3 and Patrick Bastien1,2*

Laboratoire de Parasitologie-Mycologie, Centre Hospitalier Universitaire,1 Faculté de Médecine, UMR5093 "Génome des Protozoaires Parasites,",2 CNRS/Université Montpellier I, Montpellier, France3

Received 9 May 2003/ Returned for modification 20 July 2003/ Accepted 11 January 2004

The PCR diagnosis of toxoplasmosis suffers from lack of standardization. Interlaboratory comparative studies of PCR methods have been performed, but intralaboratory comparisons are scarce. Here, we optimized and compared the technical performances of two PCR primer systems widely used for Toxoplasma detection. The differences between the two methods were visible only at low parasite concentrations (<=1 Toxoplasma genome per reaction tube). Nevertheless, when clinical samples were tested, both methods significantly differed in their technical sensitivities and specificities. Only one method appeared adequate for samples containing blood or tissue.


* Corresponding author. Mailing address: Laboratoire de Parasitologie-Mycologie, Centre Hospitalier Universitaire, 163 Rue A. Broussonet, F-34090 Montpellier, France. Phone: 33-4-67-63-27-51. Fax: 33-4-67-63-00-49. E-mail: p-bastien{at}chu-montpellier.fr.


Journal of Clinical Microbiology, April 2004, p. 1719-1722, Vol. 42, No. 4
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.4.1719-1722.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Bastien, P., Procop, G. W., Reischl, U. (2008). Quantitative Real-Time PCR Is Not More Sensitive than "Conventional" PCR. J. Clin. Microbiol. 46: 1897-1900 [Full Text]  
  • Iqbal, J., Khalid, N. (2007). Detection of acute Toxoplasma gondii infection in early pregnancy by IgG avidity and PCR analysis. J Med Microbiol 56: 1495-1499 [Abstract] [Full Text]  
  • Cassaing, S., Bessieres, M. H., Berry, A., Berrebi, A., Fabre, R., Magnaval, J. F. (2006). Comparison between Two Amplification Sets for Molecular Diagnosis of Toxoplasmosis by Real-Time PCR.. J. Clin. Microbiol. 44: 720-724 [Abstract] [Full Text]  
  • Colombo, F. A., Vidal, J. E., Oliveira, A. C. P. d., Hernandez, A. V., Bonasser-Filho, F., Nogueira, R. S., Focaccia, R., Pereira-Chioccola, V. L. (2005). Diagnosis of Cerebral Toxoplasmosis in AIDS Patients in Brazil: Importance of Molecular and Immunological Methods Using Peripheral Blood Samples. J. Clin. Microbiol. 43: 5044-5047 [Abstract] [Full Text]