This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yuan, H.-J.
Right arrow Articles by Lai, C.-L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yuan, H.-J.
Right arrow Articles by Lai, C.-L.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, August 2004, p. 3513-3517, Vol. 42, No. 8
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.8.3513-3517.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

Clinical Evaluation of the Digene Hybrid Capture II Test and the COBAS AMPLICOR Monitor Test for Determination of Hepatitis B Virus DNA Levels

He-Jun Yuan,1,2 Man-Fung Yuen,1 Danny Ka-Ho Wong,1 Simon Siu-Man Sum,1 and Ching-Lung Lai1*

Department of Medicine, The University of Hong Kong, Queen Mary Hospital, Hong Kong,1 Department of Medicine, Fudan University, Zhongshan Hospital, Shanghai, People's Republic of China2

Received 19 January 2004/ Returned for modification 22 March 2004/ Accepted 24 April 2004

The measurement of hepatitis B virus (HBV) DNA is important for the assessment of liver disease and treatment efficacy. Most commercially available assays for the determination of HBV DNA levels have limited linear ranges. This study was performed to evaluate the clinical performance of the Digene Hybrid Capture II (Digene HC II assay) and the COBAS AMPLICOR Monitor test (COBAS-AM assay), with special emphasis on anti-HBV e antigen (HBeAg)-positive patients with low HBV DNA levels. A total of 425 Chinese patients with chronic hepatitis B were recruited. A total of 107 patients were HBeAg positive, and 318 patients were HBeAg negative. The Digene HC II assay and the COBAS-AM assay had similar intra-assay and interassay variabilities. A total of 264 patients (62.1%) had HBV DNA levels undetectable by the Digene HC II assay, and 47 patients (11.1%) had HBV DNA levels undetectable by the COBAS-AM assay (P < 0.001). For the 161 patients with HBV DNA levels detectable by the Digene HC II assay, the HBV DNA levels obtained by the Digene HC II assay and by the COBAS-AM assay showed an excellent correlation (r = 0.95; P < 0.001). The linear ranges of the Digene HC II assay and the COBAS-AM assay marginally overlapped. Before HBV DNA levels could be determined by the COBAS-AM assay, predilution had to be performed for 158 of 161 patients (98.1%) with HBV DNA levels detectable by the Digene HC II assay and for 10 of 264 patients (3.8%) with HBV DNA levels undetectable by the Digene HC II assay. The cost for assaying each serum sample by using different strategies was calculated. The COBAS-AM assay was more sensitive than the Digene HC II assay and more suitable for monitoring low levels of HBV viremia.


* Corresponding author. Mailing address: Department of Medicine, The University of Hong Kong, Queen Mary Hospital, Pokfulam Rd., Hong Kong, People's Republic of China. Phone: (852) 28554252. Fax: (852) 28162863. E-mail: hrmelcl{at}hkucc.hku.hk.


Journal of Clinical Microbiology, August 2004, p. 3513-3517, Vol. 42, No. 8
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.8.3513-3517.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.