Previous Article | Next Article 
Journal of Clinical Microbiology, September 2004, p. 4307-4309, Vol. 42, No. 9
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.9.4307-4309.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Comparison of the Real-Time PCR Method and the Gen-Probe Amplified Mycobacterium tuberculosis Direct Test for Detection of Mycobacterium tuberculosis in Pulmonary and Nonpulmonary Specimens
Nadine Lemaître,1* Sylvie Armand,1 Anne Vachée,2 Odile Capilliez,1 Christine Dumoulin,1 and René J. Courcol1
Laboratoire de Bactériologie-Hygiène, Centre Hospitalier Régional Universitaire de Lille, Lille,1
Laboratoire de Biologie Polyvalente, Hôpital de Roubaix, Roubaix, France2
Received 24 February 2004/
Returned for modification 18 March 2004/
Accepted 4 May 2004
Real-time PCR was compared to Amplified Mycobacterium tuberculosis Direct Test (AMTDII) for 100 clinical specimens. The overall sensitivities of the real-time PCR method and AMTDII were similar for respiratory and nonrespiratory specimens. However, real-time PCR seemed to be less susceptible to amplification inhibitors than AMTDII.
* Corresponding author. Mailing address: Laboratoire de Bactériologie-Hygiène, Hôpital A. Calmette, CHRU de Lille, Bvd. du Professeur Jules Leclercq, 59037 Lille Cedex, France. Phone: (33) 3 20 44 45 92. Fax: (33) 3 20 44 48 95. E-mail:
n-lemaitre{at}chru-lille.fr.
Journal of Clinical Microbiology, September 2004, p. 4307-4309, Vol. 42, No. 9
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.9.4307-4309.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Campos, M., Quartin, A., Mendes, E., Abreu, A., Gurevich, S., Echarte, L., Ferreira, T., Cleary, T., Hollender, E., Ashkin, D.
(2008). Feasibility of Shortening Respiratory Isolation with a Single Sputum Nucleic Acid Amplification Test. Am. J. Respir. Crit. Care Med.
178: 300-305
[Abstract]
[Full Text]
-
Greco, S, Girardi, E, Navarra, A, Saltini, C
(2006). Current evidence on diagnostic accuracy of commercially based nucleic acid amplification tests for the diagnosis of pulmonary tuberculosis. Thorax
61: 783-790
[Abstract]
[Full Text]
-
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R. III, Smith, T. F.
(2006). Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing. Clin. Microbiol. Rev.
19: 165-256
[Abstract]
[Full Text]
-
Burggraf, S., Reischl, U., Malik, N., Bollwein, M., Naumann, L., Olgemoller, B.
(2005). Comparison of an Internally Controlled, Large-Volume LightCycler Assay for Detection of Mycobacterium tuberculosis in Clinical Samples with the COBAS AMPLICOR Assay. J. Clin. Microbiol.
43: 1564-1569
[Abstract]
[Full Text]