Previous Article | Next Article 
Journal of Clinical Microbiology, March 2006, p. 729-737, Vol. 44, No. 3
0095-1137/06/$08.00+0 doi:10.1128/JCM.44.3.729-737.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.
Comparison of Conventional PCR with Real-Time PCR and Branched DNA-Based Assays for Hepatitis C Virus RNA Quantification and Clinical Significance for Genotypes 1 to 5
Christoph Sarrazin,1*
Barbara C. Gärtner,2
Dorothea Sizmann,3
Rainer Babiel,3
Ulrike Mihm,1
Wolf Peter Hofmann,1
Michael von Wagner,1 and
Stefan Zeuzem1
Klinik für Innere Medizin II, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421 Homburg/Saar, Germany,1
Abteilung für Virologie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421 Homburg/Saar, Germany,2
Roche Diagnostics, Molecular Diagnostics Development, Nonnenwald 2, 82372 Penzberg, Germany3
Received 16 August 2005/
Returned for modification 28 September 2005/
Accepted 1 December 2005
The key parameter for diagnosis and management of hepatitis C virus (HCV) infection is HCV RNA. Standardization of HCV RNA assays to IU is mainly based on genotype 1 panels. Little is known about the variability of commercially available HCV RNA assays for quantification of different genotypes. Two real-time reverse transcription (RT)-PCR assays (COBAS TaqMan HCV Test for use with the High-Pure System [HPS/CTM] and COBAS Ampliprep/COBAS TaqMan HCV Test [CAP/CTM]), one standard RT-PCR assay (COBAS Amplicor HCV Monitor 2.0 [CAM]), and one signal amplification assay (Versant Quantitative 3.0 [branched DNA {bDNA}]) were compared for quantification of genotypes 1 to 5 (n = 108). Using CAM as a reference assay for genotype 1-infected patients, the mean interassay differences compared with CAP/CTM, HPS/CTM, and bDNA were 0.16, 0.13, and 0.48 log10 IU/ml HCV RNA, respectively. Comparison of CAM with CAP/CTM, HPS/CTM, and bDNA for the remaining genotypes showed the following results, respectively: 2a/c, 0.24, 0.78, and 0.49; 2b, 0.21, 0.18, and 0.64; 3a, 0.13, 1.04, and 0.55; 4, 0.52, 1.51, and 0.05; and 5, 0.28, 1.00, and 0.24 log IU/ml HCV RNA. A correct decision for treatment discontinuation in genotype 1 patients at week 12 was possible only when the same assay was used at baseline and week 12. Comparison of CAM with the CAP/CTM assay showed equal quantifications of genotype 1, 2, 3, and 5 samples, while genotype 4 samples were slightly underestimated. For the HPS/CTM assay, a significant underestimation of the HCV RNA concentrations of genotypes 2a/c, 3, 4, and 5 was observed. For the bDNA assay, a constant lower quantification of genotypes 1 to 3 was detected.
* Corresponding author. Mailing address: Klinik für Innere Medizin II, Universitätsklinikum des Saarlandes, Kirrberger Str., D-66421 Homburg/Saar, Germany. Phone: 49-6841-16-23203. Fax: 49-6841-16-23264. E-mail:
christoph.sarrazin{at}uniklinik-saarland.de.
Journal of Clinical Microbiology, March 2006, p. 729-737, Vol. 44, No. 3
0095-1137/06/$08.00+0 doi:10.1128/JCM.44.3.729-737.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Bruns, T., Steinmetzer, K., Ermantraut, E., Stallmach, A.
(2009). Hepatitis C Virus RNA Quantitation in Venous and Capillary Small-Volume Whole-Blood Samples. J. Clin. Microbiol.
47: 3231-3240
[Abstract]
[Full Text]
-
Pyne, M. T., Konnick, E. Q., Phansalkar, A., Hillyard, D. R.
(2009). Evaluation of the Abbott Investigational Use Only RealTime Hepatitis C Virus (HCV) Assay and Comparison to the Roche TaqMan HCV Analyte-Specific Reagent Assay. J. Clin. Microbiol.
47: 2872-2878
[Abstract]
[Full Text]
-
Vermehren, J., Kau, A., Gartner, B. C., Gobel, R., Zeuzem, S., Sarrazin, C.
(2008). Differences between Two Real-Time PCR-Based Hepatitis C Virus (HCV) Assays (RealTime HCV and Cobas AmpliPrep/Cobas TaqMan) and One Signal Amplification Assay (Versant HCV RNA 3.0) for RNA Detection and Quantification. J. Clin. Microbiol.
46: 3880-3891
[Abstract]
[Full Text]
-
Kim, S., Kim, J.-H., Yoon, S., Park, Y.-H., Kim, H.-S.
(2008). Clinical Performance Evaluation of Four Automated Chemiluminescence Immunoassays for Hepatitis C Virus Antibody Detection. J. Clin. Microbiol.
46: 3919-3923
[Abstract]
[Full Text]
-
Forman, M. S., Valsamakis, A.
(2008). Performance Characteristics of a Quantitative Hepatitis C Virus RNA Assay Using COBAS AmpliPrep Total Nucleic Acid Isolation and COBAS TaqMan Hepatitis C Virus Analyte-Specific Reagent. J. Mol. Diagn.
10: 147-153
[Abstract]
[Full Text]
-
Colucci, G., Ferguson, J., Harkleroad, C., Lee, S., Romo, D., Soviero, S., Thompson, J., Velez, M., Wang, A., Miyahara, Y., Young, S., Sarrazin, C.
(2007). Improved COBAS TaqMan Hepatitis C Virus Test (Version 2.0) for Use with the High Pure System: Enhanced Genotype Inclusivity and Performance Characteristics in a Multisite Study. J. Clin. Microbiol.
45: 3595-3600
[Abstract]
[Full Text]
-
Laperche, S., Bouchardeau, F., Thibault, V., Pozzetto, B., Vallet, S., Rosenberg, A. R., Roque-Afonso, A.-M., Gassin, M., Stoll-Keller, F., Trimoulet, P., Gault, E., Chanzy, B., Mercier, B., Branger, M., Pawlotsky, J.-M., Henquell, C., Lunel, F., Gaudy-Graffin, C., Alain, S., Chaix, M.-L., Duverlie, G., Izopet, J., Lefrere, J.-J.
(2007). Multicenter Trials Need To Use the Same Assay for Hepatitis C Virus Viral Load Determination. J. Clin. Microbiol.
45: 3788-3790
[Abstract]
[Full Text]
-
Tuaillon, E., Mondain, A.-M., Ottomani, L., Roudiere, L., Perney, P., Picot, M.-C., Seguret, F., Blanc, F., Larrey, D., Van de Perre, P., Ducos, J.
(2007). Impact of Hepatitis C Virus (HCV) Genotypes on Quantification of HCV RNA in Serum by COBAS AmpliPrep/COBAS TaqMan HCV Test, Abbott Antiretroviral Therapy HCV RealTime Assay, and VERSANT HCV RNA Assay. J. Clin. Microbiol.
45: 3077-3081
[Abstract]
[Full Text]
-
Sabato, M. F., Shiffman, M. L., Langley, M. R., Wilkinson, D. S., Ferreira-Gonzalez, A.
(2007). Comparison of Performance Characteristics of Three Real-Time Reverse Transcription-PCR Test Systems for Detection and Quantification of Hepatitis C Virus. J. Clin. Microbiol.
45: 2529-2536
[Abstract]
[Full Text]
-
Schutten, M., Peters, D., Back, N. K. T., Beld, M., Beuselinck, K., Foulongne, V., Geretti, A.-M., Pandiani, L., Tiemann, C., Niesters, H. G. M.
(2007). Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA. J. Clin. Microbiol.
45: 1712-1717
[Abstract]
[Full Text]