Previous Article | Next Article 
Journal of Clinical Microbiology, October 2007, p. 3436-3438, Vol. 45, No. 10
0095-1137/07/$08.00+0 doi:10.1128/JCM.00973-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.
Human Immunodeficiency Virus Type 1 (HIV-1) Plasma Load Discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Assays
F. Damond,1*
B. Roquebert,1
A. Bénard,2
G. Collin,1
M. Miceli,1
P. Yéni,3
F. Brun-Vezinet,1 and
D. Descamps1
Laboratoire de Virologie, Hôpital Bichat Claude Bernard, Paris, France,1
INSERM U593, ISPED Bordeaux F33076, France,2
Service Maladies Tropicales et Infectieuses, Hopital Bichat Claude Bernard, Paris, France3
Received 10 May 2007/
Returned for modification 11 July 2007/
Accepted 27 July 2007
We compared plasma viral load values obtained with COBAS AMPLICOR human immunodeficiency virus type 1 (HIV-1) MONITOR version 1.5 and with COBAS TaqMan HIV-1 assays. Mean values were 4.2 and 2.9 log10 copies/ml, respectively, showing the lack of agreement between the two assays.
* Corresponding author. Mailing address: Laboratoire de Virologie, Hôpital Bichat Claude Bernard, 75018 Paris, France. Phone: 33 1 40 25 61 51. Fax: 33 1 40 25 67 69. E-mail:
florence.damond{at}bch.aphp.fr
Published ahead of print on 22 August 2007.
Journal of Clinical Microbiology, October 2007, p. 3436-3438, Vol. 45, No. 10
0095-1137/07/$08.00+0 doi:10.1128/JCM.00973-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Delaugerre, C., Denis, B., Peytavin, G., Palmer, P., Mourez, T., Le Goff, J., Molina, J.-M., Simon, F.
(2009). Clinical and Resistance Consequences of Misquantification of Plasma and Cerebrospinal Fluid Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Samples from an HIV-1 Subtype G-Infected Patient. J. Clin. Microbiol.
47: 3763-3764
[Abstract]
[Full Text]
-
Scott, L. E., Noble, L. D., Moloi, J., Erasmus, L., Venter, W. D. F., Stevens, W.
(2009). Evaluation of the Abbott m2000 RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay for HIV Load Monitoring in South Africa Compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 Assays. J. Clin. Microbiol.
47: 2209-2217
[Abstract]
[Full Text]
-
Wirden, M., Tubiana, R., Marguet, F., Leroy, I., Simon, A., Bonmarchand, M., Ait-Arkoub, Z., Murphy, R., Marcelin, A. G., Katlama, C., Calvez, V.
(2009). Impact of Discrepancies between the Abbott RealTime and Cobas TaqMan Assays for Quantification of Human Immunodeficiency Virus Type 1 Group M Non-B Subtypes. J. Clin. Microbiol.
47: 1543-1545
[Abstract]
[Full Text]
-
Sloma, C. R., Germer, J. J., Gerads, T. M., Mandrekar, J. N., Mitchell, P. S., Yao, J. D. C.
(2009). Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs. J. Clin. Microbiol.
47: 889-895
[Abstract]
[Full Text]
-
Korn, K., Weissbrich, B., Henke-Gendo, C., Heim, A., Jauer, C. M., Taylor, N., Eberle, J.
(2009). Single-Point Mutations Causing More than 100-Fold Underestimation of Human Immunodeficiency Virus Type 1 (HIV-1) Load with the Cobas TaqMan HIV-1 Real-Time PCR Assay. J. Clin. Microbiol.
47: 1238-1240
[Abstract]
[Full Text]
-
Holguin, A., Lopez, M., Molinero, M., Soriano, V.
(2008). Performance of Three Commercial Viral Load Assays, Versant Human Immunodeficiency Virus Type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, Testing HIV-1 Non-B Subtypes and Recombinant Variants. J. Clin. Microbiol.
46: 2918-2923
[Abstract]
[Full Text]
-
Yao, J. D. C., Germer, J. J., Damond, F., Roquebert, B., Descamps, D.
(2008). Plasma Load Discrepancies between the Roche Cobas Amplicor Human Immunodeficiency Virus Type 1 (HIV-1) Monitor Version 1.5 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Assays. J. Clin. Microbiol.
46: 834-834
[Full Text]