This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sharma, M. K.
Right arrow Articles by Vijayaraghavan, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sharma, M. K.
Right arrow Articles by Vijayaraghavan, R.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, November 2008, p. 3759-3765, Vol. 46, No. 11
0095-1137/08/$08.00+0     doi:10.1128/JCM.01022-08
Copyright © 2008, American Society for Microbiology. All Rights Reserved.

Highly Sensitive Amperometric Immunosensor for Detection of Plasmodium falciparum Histidine-Rich Protein 2 in Serum of Humans with Malaria: Comparison with a Commercial Kit{triangledown}

Mukesh K. Sharma,1 Vepa K. Rao,1* Gauri S. Agarwal,1 Ganga P. Rai,1 N. Gopalan,1 Shri Prakash,1 S. K. Sharma,2 and R. Vijayaraghavan1

Defence Research and Development Establishment, Jhansi Road, Gwalior-474002, India,1 National Institute of Malaria Research Field Station, Rourkela-769002, India2

Received 29 May 2008/ Returned for modification 31 July 2008/ Accepted 8 September 2008

A disposable amperometric immunosensor was developed for the detection of Plasmodium falciparum histidine-rich protein 2 (PfHRP-2) in the sera of humans with P. falciparum malaria. For this purpose, disposable screen-printed electrodes (SPEs) were modified with multiwall carbon nanotubes (MWCNTs) and Au nanoparticles. The electrodes were characterized by cyclic voltammetry, scanning electron microscopy, and Raman spectroscopy. In order to study the immunosensing performances of modified electrodes, a rabbit anti-PfHRP-2 antibody (as the capturing antibody) was first immobilized on an electrode. Further, the electrode was exposed to a mouse anti-PfHRP-2 antibody from a serum sample (as the revealing antibody), followed by a rabbit anti-mouse immunoglobulin G-alkaline phosphatase conjugate. The immunosensing experiments were performed on bare SPEs, MWCNT-modified SPEs, and Au nanoparticle- and MWCNT-modified SPEs (Nano-Au/MWCNT/SPEs) for the amperometric detection of PfHRP-2 in a solution of 0.1 M diethanolamine buffer, pH 9.8, by applying a potential of 450 mV at the working electrode. Nano-Au/MWCNT/SPEs yielded the highest-level immunosensing performance among the electrodes, with a detection limit of 8 ng/ml. The analytical results of immunosensing experiments with human serum samples were compared with the results of a commercial Paracheck Pf test, as well as the results of microscopy. The specificities, sensitivities, and positive and negative predictive values of the Paracheck Pf and amperometric immunosensors were calculated by taking the microscopy results as the "gold standard." The Paracheck Pf kit exhibited a sensitivity of 79% (detecting 34 of 43 positive samples; 95% confidence interval [CI], 75 to 86%) and a specificity of 81% (correctly identifying 57 of 70 negative samples; 95% CI, 76 to 92%), whereas the developed amperometric immunosensor showed a sensitivity of 96% (detecting 41 of 43 positive samples; 95% CI, 93 to 98%) and a specificity of 94% (correctly identifying 66 of 70 negative samples; 95% CI, 92 to 99%). The developed method is more sensitive and specific than the Paracheck Pf kit.


* Corresponding author. Mailing address: Biosensor Development Division, DRDE, Jhansi Rd., Gwalior-474002, India. Phone: 91-751-2230016. Fax: 91-751-2341148. E-mail: vepakrao{at}yahoo.com

{triangledown} Published ahead of print on 17 September 2008.


Journal of Clinical Microbiology, November 2008, p. 3759-3765, Vol. 46, No. 11