Skip to main content
  • ASM
    • Antimicrobial Agents and Chemotherapy
    • Applied and Environmental Microbiology
    • Clinical Microbiology Reviews
    • Clinical and Vaccine Immunology
    • EcoSal Plus
    • Eukaryotic Cell
    • Infection and Immunity
    • Journal of Bacteriology
    • Journal of Clinical Microbiology
    • Journal of Microbiology & Biology Education
    • Journal of Virology
    • mBio
    • Microbiology and Molecular Biology Reviews
    • Microbiology Resource Announcements
    • Microbiology Spectrum
    • Molecular and Cellular Biology
    • mSphere
    • mSystems
  • Log in
  • My alerts
  • My Cart

Main menu

  • Home
  • Articles
    • Current Issue
    • Accepted Manuscripts
    • COVID-19 Special Collection
    • Archive
    • Minireviews
  • For Authors
    • Submit a Manuscript
    • Scope
    • Editorial Policy
    • Submission, Review, & Publication Processes
    • Organization and Format
    • Errata, Author Corrections, Retractions
    • Illustrations and Tables
    • Nomenclature
    • Abbreviations and Conventions
    • Publication Fees
    • Ethics Resources and Policies
  • About the Journal
    • About JCM
    • Editor in Chief
    • Editorial Board
    • For Reviewers
    • For the Media
    • For Librarians
    • For Advertisers
    • Alerts
    • RSS
    • FAQ
  • Subscribe
    • Members
    • Institutions
  • ASM
    • Antimicrobial Agents and Chemotherapy
    • Applied and Environmental Microbiology
    • Clinical Microbiology Reviews
    • Clinical and Vaccine Immunology
    • EcoSal Plus
    • Eukaryotic Cell
    • Infection and Immunity
    • Journal of Bacteriology
    • Journal of Clinical Microbiology
    • Journal of Microbiology & Biology Education
    • Journal of Virology
    • mBio
    • Microbiology and Molecular Biology Reviews
    • Microbiology Resource Announcements
    • Microbiology Spectrum
    • Molecular and Cellular Biology
    • mSphere
    • mSystems

User menu

  • Log in
  • My alerts
  • My Cart

Search

  • Advanced search
Journal of Clinical Microbiology
publisher-logosite-logo

Advanced Search

  • Home
  • Articles
    • Current Issue
    • Accepted Manuscripts
    • COVID-19 Special Collection
    • Archive
    • Minireviews
  • For Authors
    • Submit a Manuscript
    • Scope
    • Editorial Policy
    • Submission, Review, & Publication Processes
    • Organization and Format
    • Errata, Author Corrections, Retractions
    • Illustrations and Tables
    • Nomenclature
    • Abbreviations and Conventions
    • Publication Fees
    • Ethics Resources and Policies
  • About the Journal
    • About JCM
    • Editor in Chief
    • Editorial Board
    • For Reviewers
    • For the Media
    • For Librarians
    • For Advertisers
    • Alerts
    • RSS
    • FAQ
  • Subscribe
    • Members
    • Institutions
Bacteriology

Multicenter Comparison of BACTEC 9050 and BACTEC 9240 Blood Culture Systems

Patrick R. Murray, Gary E. Hollick, Robert C. Jerris, Michael L. Wilson
Patrick R. Murray
Division of Laboratory Medicine, Washington University, St. Louis, Missouri;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gary E. Hollick
Microbiology Laboratory, Rochester General Hospital, Rochester, New York;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Robert C. Jerris
DeKalb Medical Center, Decatur, Georgia; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael L. Wilson
Denver Health Medical Center, Denver, Colorado
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
DOI: 10.1128/JCM.36.6.1601-1603.1998
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

ABSTRACT

The overall recovery of organisms and time to detection with the BACTEC 9050 and BACTEC 9240 systems were compared in a multicenter evaluation. In the first phase of the study, a total of 4,383 compliant aerobic (Plus Aerobic/F) blood culture sets were processed. There was no significant difference in the recovery of individual groups of organisms with the two systems, with the exception ofStreptococcus pneumoniae which was isolated more frequently with BACTEC 9050. False-positive signals occurred more often with BACTEC 9240 (58 cultures) than with BACTEC 9050 (43 cultures), but false-negative cultures were uncommon with both systems (3 cultures for each system). Time to detection of positive cultures of clinically significant organisms was essentially the same with both instruments. In the second phase of the study, 2,431 compliant anaerobic (Plus Anaerobic/F) blood culture sets were processed. There was no significant difference in the recovery of organisms with BACTEC 9050 compared with BACTEC 9240. Significantly (P < 0.03) more false-positive signals occurred with BACTEC 9240 (15 cultures) than with BACTEC 9050 (4 cultures). Likewise, more false-negative cultures occurred with BACTEC 9240 (11 cultures) than with BACTEC 9050 (8 cultures). Time to detection of positive cultures of clinically significant organisms was essentially the same with both systems with the exception of anaerobes (N = 10), which were recovered earlier (P < 0.01) with BACTEC 9240 (35.0 h) than with BACTEC 9050 (61.4 h).

The BACTEC 9000 series of blood culture systems (Becton Dickinson Microbiology Systems, Sparks, Md.) are fluorogenic, automated, noninvasive blood culture systems. Two models, BACTEC 9240 (240-bottle capacity) and BACTEC 9120 (120-bottle capacity), are essentially identical in design and differ only in their bottle capacity. Recently, a third model was introduced for use in small laboratories or clinics that process relatively few blood cultures. BACTEC 9050, with a capacity of 50 bottles, is a small, self-contained, automated system designed for processing three to five blood cultures per day. In addition to the difference in capacity, BACTEC 9050 differs from the larger systems by agitating the bottles continuously (versus intermittently for the other systems) and rotating the bottles to be read by one of three detectors (versus a dedicated detector for each stationary bottle in the large systems). The computer used to monitor the BACTEC 9050 bottles is contained within the system. Previous evaluations of the larger BACTEC 9000 instruments demonstrated excellent recovery and time of detection of positive blood cultures (1, 2, 4-7). In this evaluation, the performance properties of BACTEC 9050, using Plus Aerobic/F and Plus Anaerobic/F blood culture bottles, were compared with those of BACTEC 9240.

MATERIALS AND METHODS

Study participants.This study was performed in four clinical laboratories: Barnes-Jewish Hospital in St. Louis, Mo.; Rochester General Hospital in Rochester, N.Y.; DeKalb Medical Center, Decatur, Ga.; and Denver Health Medical Center, Denver, Colo.

Study design.The performance of the BACTEC 9050 system was compared with that of the BACTEC 9240 system. In phase 1 of the study, the performance of Plus Aerobic/F medium was evaluated in the two systems. A total volume of 14 to 22 ml of blood was collected aseptically, divided equally into two Plus Aerobic/F bottles, and transported to the study laboratories. One bottle was placed into each instrument after it was determined that an equal volume of 7 to 11 ml of blood was inoculated into each bottle. Compliance was determined by measuring blood volumes when the bottles were received in the laboratories. All bottles were incubated for a minimum of 5 days according to the manufacturer’s protocol. When a positive signal was obtained, the bottles were removed and an aliquot of the broth was Gram stained and processed for organism identification. Bottles with a false-positive signal were returned to the system for further incubation and testing. All negative bottles were subcultured blindly to chocolate agar plates and incubated aerobically at the end of the incubation period.

Phase 2 of the study was the evaluation of the Plus Anaerobic/F medium. A total volume of 14 to 22 ml of blood was collected aseptically, divided equally into Plus Anaerobic/F bottles, and transported to the study laboratories (Barnes-Jewish Hospital did not participate in this phase of the study). All subsequent processing was done as described above.

Data analysis.The modified chi-square test described by McNemar (3) was used to assess the statistical significance of differences observed between the two culture systems. When appropriate, the Yates correction for small numbers of observations was used.

RESULTS AND DISCUSSION

In the phase 1 aerobic comparison, 4,382 compliant blood culture sets were received and processed. A total of 585 (13.4%) positive cultures were detected with one or both BACTEC systems, a false-positive result (positive result with the BACTEC system but negative results for Gram stain and subculture) was recorded for 83 (1.9%) cultures, and 3,714 (84.7%) cultures had negative results. From the positive culture bottles, 651 organisms were isolated, including 366 judged to be clinically significant, 242 clinically insignificant, and 43 of unknown significance. Overall recovery of clinically significant organisms in the BACTEC 9050 and BACTEC 9240 systems is summarized in Table 1. The total numbers of organisms isolated with the BACTEC 9050 and BACTEC 9240 systems were 320 and 303, respectively. There was no significant difference in the recovery of individual groups of organisms in the two systems, with the exception of Streptococcus pneumoniae. Of the 29 cultures positive with S. pneumoniae, 8 were detected only with BACTEC 9050 and 1 was detected only with BACTEC 9240 (P < 0.05).

View this table:
  • View inline
  • View popup
Table 1.

Recovery of clinically significant organisms from BACTEC Plus Aerobic/F bottles

Equal numbers of clinically insignificant organisms were recovered with the two systems (144 isolates with each system), with the coagulase-negative staphylococci and Corynebacterium species the most common contaminants. A total of 43 organisms of unknown clinical significance was isolated in this phase of the study, with 30 and 26 recovered with the BACTEC 9050 and BACTEC 9240 systems, respectively.

False-positive results were observed in 83 cultures, including 17 cultures with both bottles positive, 40 cultures positive only with the BACTEC 9240 system, and 26 cultures positive only with the BACTEC 9050 system.

All negative blood culture bottles were blindly subcultured as described above. An additional six positive bottles, all with isolates of clinically significant organisms, were detected. Three BACTEC 9240 bottles were positive with Candida glabrata (the companion BACTEC 9050 bottles were negative), and three BACTEC 9050 bottles were positive for individual isolates of C. glabrata,Corynebacterium jeikeium, and Streptococcus constellatus (the companion BACTEC 9240 bottles were positive forC. jeikeium and S. constellatus but not forC. glabrata).

In the second phase of the study, 2,431 compliant blood culture sets were processed in the Plus Anaerobic/F medium. A total of 284 (11.7%) positive cultures were detected, a false-positive result was observed for 19 (0.8%) cultures (including 3 cultures with a true-positive companion bottle), and 2,131 (87.7%) cultures had negative results. From the positive culture bottles, 316 organisms were recovered, including 197 clinically significant isolates, 101 clinically insignificant isolates, and 18 organisms of unknown significance. The recovery of clinically significant organisms in the two systems is summarized in Table 2. There was no significant difference in the overall recovery of organisms with BACTEC 9050 (total recovery, 177 isolates) or BACTEC 9240 (170 isolates) or in the recovery of any individual group of organisms.

View this table:
  • View inline
  • View popup
Table 2.

Recovery of clinically significant organisms from the BACTEC Plus Anaerobic/F bottles

A total of 101 clinically insignificant organisms were recovered in this phase of the study, 60 with BACTEC 9050 and 61 with BACTEC 9240. In addition, the recovery of organisms with unknown clinical significance with the two systems was not significantly different (i.e., 14 with BACTEC 9050 and 10 with BACTEC 9240).

A total of 19 false-positive cultures were observed in the second phase of the study. There were 15 false-positive cultures with the BACTEC 9240 system and 4 with the BACTEC 9050 system (P < 0.03).

A total of 19 organisms were detected in 15 cultures by blind subculture. Eleven organisms including four clinically significant ones (two Clostridium spp., one Pseudomonas aeruginosa, and one unidentified anaerobic gram-negative bacillus) were present in BACTEC 9240 cultures and eight organisms including two clinically significant ones (one P. aeruginosa isolate and one Staphylococcus aureus isolate) were present in BACTEC 9050 cultures. Only two clinically significant isolates (one S. aureus and one Clostridium spp.) were detected by a positive signal in the companion bottle.

The time to detect positive cultures of clinically significant organisms is summarized in Tables 3 and4. The time for detection using the Plus Aerobic/F bottles was essentially the same for the BACTEC 9050 system (mean detection time, 19.3 h) and the BACTEC 9240 system (19.1 h). All groups of organisms were detected rapidly, with the exception of the coagulase-negative staphylococci, Corynebacterium spp., yeasts, and Mycobacterium fortuitum (one isolate only). It is interesting to note that the time for detecting growth of yeasts was influenced by the species, with relatively rapid detection observed forCandida albicans (five isolates; mean detection time, 49.2 h with BACTEC 9050 and 44.0 h with BACTEC 9240) andCandida tropicalis (two isolates; 25.2 and 33.4 h) and slower detection of C. glabrata (two isolates; 134.1 and 149.6 h) and Cryptococcus neoformans (two isolates; 79.2 and 78.8 h).

View this table:
  • View inline
  • View popup
Table 3.

Average time to detection with the BACTEC Plus Aerobic/F bottles

View this table:
  • View inline
  • View popup
Table 4.

Average time to detection with the BACTEC Plus Anaerobic/F bottles

The time for detection using the Plus Anaerobic/F bottles was similar for both systems (i.e., 17.8 h with the BACTEC 9050 system and 15.7 h with the BACTEC 9240 system). The observed difference in overall detection time was attributed to the slower recovery of five isolates of non-Bacteroides anaerobic bacteria (P < 0.01) with BACTEC 9050 (mean detection time, 81.7 h) than with BACTEC 9240 (mean, 30.5 h).

In summary, the overall recovery of organisms and time for detection of positive cultures with the BACTEC 9050 and 9240 blood culture systems were essentially the same. Minor differences between the two systems include better recovery of S. pneumoniae, fewer false-positive aerobic and anaerobic bottles, and fewer false-negative anaerobic bottles with the BACTEC 9050 system, and faster detection of anaerobic bacteria in anaerobic bottles incubated in the BACTEC 9240 system. During this evaluation, no technical failures were observed with the multiple BACTEC 9050 instruments used in the four study sites, and all study participants found the system to be easy to use. The BACTEC 9050 system is well suited for laboratories that process relatively few blood culture bottles and should offer significant advantages over the manual or older semiautomated blood culture systems that are used in these laboratories.

ACKNOWLEDGMENTS

We thank the technologists in our laboratories for their assistance.

Support for this study was provided by Becton Dickinson Microbiology Systems.

FOOTNOTES

    • Received 2 December 1997.
    • Accepted 11 March 1998.
  • Copyright © 1998 American Society for Microbiology

REFERENCES

  1. 1.↵
    1. Cockerill F. R.,
    2. Reed G. S.,
    3. Hughes J. G.,
    4. Torgerson C. A.,
    5. Vetter E. A.,
    6. Harmesen W. S.,
    7. Dale J. C.,
    8. Roberts G. D.,
    9. Ilstrup D. M.,
    10. Henry N. K.
    Clinical comparison of BACTEC 9240 Plus Aerobic/F resin bottles and the Isolator aerobic culture system for detection of bloodstream infections.J. Clin. Microbiol. 35 1997 1469 1472
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Jorgensen J. H.,
    2. Mirrett S.,
    3. McDonald L. C.,
    4. Murray P. R.,
    5. Weinstein M. P.,
    6. Fune J.,
    7. Trippy C. W.,
    8. Masterson M.,
    9. Reller L. B.
    Controlled clinical laboratory comparison of BACTEC Plus Aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.J. Clin. Microbiol. 35 1997 53 58
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    1. McNemar Q.
    Psychological statistics 3rd ed. 1962 209 239 John Wiley & Sons, Inc. New York, N.Y
  4. 4.↵
    1. Nolte F. S.,
    2. Williams J. M.,
    3. Jerris R. C.,
    4. Morello J. A.,
    5. Leitch C. D.,
    6. Matushek S.,
    7. Schwabe L. D.,
    8. Dorigan F.,
    9. Kocka F. E.
    Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240).J. Clin. Microbiol. 31 1993 552 557
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Pohlman J. K.,
    2. Kirkley B. A.,
    3. Easley K. A.,
    4. Basille B. A.,
    5. Washington J. A.
    Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert aerobic FAN bottles for detection of bloodstream infections.J. Clin. Microbiol. 33 1995 2856 2858
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Pohlman J. K.,
    2. Kirkley B. A.,
    3. Easley K. A.,
    4. Washington J. A.
    Controlled clinical comparison of Isolator and BACTEC 9240 Aerobic/F resin bottle for detection of bloodstream infections.J. Clin. Microbiol. 33 1995 2525 2529
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Smith J. A.,
    2. Bryce E. A.,
    3. Ngui-Yen J. H.,
    4. Roberts F. J.
    Comparison of BACTEC 9240 and BacT/Alert blood culture systems in an adult hospital.J. Clin. Microbiol. 33 1995 1905 1908
    OpenUrlAbstract/FREE Full Text
View Abstract
PreviousNext
Back to top
Download PDF
Citation Tools
Multicenter Comparison of BACTEC 9050 and BACTEC 9240 Blood Culture Systems
Patrick R. Murray, Gary E. Hollick, Robert C. Jerris, Michael L. Wilson
Journal of Clinical Microbiology Jun 1998, 36 (6) 1601-1603; DOI: 10.1128/JCM.36.6.1601-1603.1998

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Print

Alerts
Sign In to Email Alerts with your Email Address
Email

Thank you for sharing this Journal of Clinical Microbiology article.

NOTE: We request your email address only to inform the recipient that it was you who recommended this article, and that it is not junk mail. We do not retain these email addresses.

Enter multiple addresses on separate lines or separate them with commas.
Multicenter Comparison of BACTEC 9050 and BACTEC 9240 Blood Culture Systems
(Your Name) has forwarded a page to you from Journal of Clinical Microbiology
(Your Name) thought you would be interested in this article in Journal of Clinical Microbiology.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Multicenter Comparison of BACTEC 9050 and BACTEC 9240 Blood Culture Systems
Patrick R. Murray, Gary E. Hollick, Robert C. Jerris, Michael L. Wilson
Journal of Clinical Microbiology Jun 1998, 36 (6) 1601-1603; DOI: 10.1128/JCM.36.6.1601-1603.1998
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Top
  • Article
    • ABSTRACT
    • MATERIALS AND METHODS
    • RESULTS AND DISCUSSION
    • ACKNOWLEDGMENTS
    • FOOTNOTES
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

KEYWORDS

bacteria
blood
fungi
Microbiological Techniques

Related Articles

Cited By...

About

  • About JCM
  • Editor in Chief
  • Board of Editors
  • Editor Conflicts of Interest
  • For Reviewers
  • For the Media
  • For Librarians
  • For Advertisers
  • Alerts
  • RSS
  • FAQ
  • Permissions
  • Journal Announcements

Authors

  • ASM Author Center
  • Submit a Manuscript
  • Article Types
  • Resources for Clinical Microbiologists
  • Ethics
  • Contact Us

Follow #JClinMicro

@ASMicrobiology

       

ASM Journals

ASM journals are the most prominent publications in the field, delivering up-to-date and authoritative coverage of both basic and clinical microbiology.

About ASM | Contact Us | Press Room

 

ASM is a member of

Scientific Society Publisher Alliance

 

American Society for Microbiology
1752 N St. NW
Washington, DC 20036
Phone: (202) 737-3600

 

Copyright © 2021 American Society for Microbiology | Privacy Policy | Website feedback

Print ISSN: 0095-1137; Online ISSN: 1098-660X