Skip to main content
  • ASM
    • Antimicrobial Agents and Chemotherapy
    • Applied and Environmental Microbiology
    • Clinical Microbiology Reviews
    • Clinical and Vaccine Immunology
    • EcoSal Plus
    • Eukaryotic Cell
    • Infection and Immunity
    • Journal of Bacteriology
    • Journal of Clinical Microbiology
    • Journal of Microbiology & Biology Education
    • Journal of Virology
    • mBio
    • Microbiology and Molecular Biology Reviews
    • Microbiology Resource Announcements
    • Microbiology Spectrum
    • Molecular and Cellular Biology
    • mSphere
    • mSystems
  • Log in
  • My alerts
  • My Cart

Main menu

  • Home
  • Articles
    • Current Issue
    • Accepted Manuscripts
    • COVID-19 Special Collection
    • Archive
    • Minireviews
  • For Authors
    • Submit a Manuscript
    • Scope
    • Editorial Policy
    • Submission, Review, & Publication Processes
    • Organization and Format
    • Errata, Author Corrections, Retractions
    • Illustrations and Tables
    • Nomenclature
    • Abbreviations and Conventions
    • Publication Fees
    • Ethics Resources and Policies
  • About the Journal
    • About JCM
    • Editor in Chief
    • Editorial Board
    • For Reviewers
    • For the Media
    • For Librarians
    • For Advertisers
    • Alerts
    • RSS
    • FAQ
  • Subscribe
    • Members
    • Institutions
  • ASM
    • Antimicrobial Agents and Chemotherapy
    • Applied and Environmental Microbiology
    • Clinical Microbiology Reviews
    • Clinical and Vaccine Immunology
    • EcoSal Plus
    • Eukaryotic Cell
    • Infection and Immunity
    • Journal of Bacteriology
    • Journal of Clinical Microbiology
    • Journal of Microbiology & Biology Education
    • Journal of Virology
    • mBio
    • Microbiology and Molecular Biology Reviews
    • Microbiology Resource Announcements
    • Microbiology Spectrum
    • Molecular and Cellular Biology
    • mSphere
    • mSystems

User menu

  • Log in
  • My alerts
  • My Cart

Search

  • Advanced search
Journal of Clinical Microbiology
publisher-logosite-logo

Advanced Search

  • Home
  • Articles
    • Current Issue
    • Accepted Manuscripts
    • COVID-19 Special Collection
    • Archive
    • Minireviews
  • For Authors
    • Submit a Manuscript
    • Scope
    • Editorial Policy
    • Submission, Review, & Publication Processes
    • Organization and Format
    • Errata, Author Corrections, Retractions
    • Illustrations and Tables
    • Nomenclature
    • Abbreviations and Conventions
    • Publication Fees
    • Ethics Resources and Policies
  • About the Journal
    • About JCM
    • Editor in Chief
    • Editorial Board
    • For Reviewers
    • For the Media
    • For Librarians
    • For Advertisers
    • Alerts
    • RSS
    • FAQ
  • Subscribe
    • Members
    • Institutions
LETTERS TO THE EDITOR

False-Negative Culture Results with Fungal Isolates from Peritoneal Dialysis Fluid

Jason D. Pimentel, Gary D. Lum
Jason D. Pimentel
Northern Territory Government Pathology Service Royal Darwin Hospital P.O. Box 41326 Casuarina NT, 0811, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: pimentel@iprimus.com.au
Gary D. Lum
Northern Territory Government Pathology Service Royal Darwin Hospital P.O. Box 41326 Casuarina NT, 0811, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
DOI: 10.1128/JCM.44.3.1206.2006
  • Article
  • Info & Metrics
  • PDF
Loading

Recently, newly reported causes of fungal peritonitis associated with continuous ambulatory peritoneal dialysis were described both in this journal and in another (6, 7). These episodes threatened to go undetected due to false-negative culture results in the initial investigations.

Each of these cases involved inoculation of peritoneal dialysis (PD) fluid into BACTEC (Becton Dickinson) blood culture bottles with incubation in a BACTEC 9240 (Becton Dickinson) system. This approach for culturing PD fluid is not novel. It has been previously established that the sensitivity of detecting organisms in a sterile fluid can be greatly increased by using a large volume of inoculum and a large volume of media (10). In the clinical microbiology laboratory, this is conveniently achieved with blood culture bottles. Superior performance using blood culture bottles compared to conventional culturing has been noted for the recovery of organisms from synovial (10), ascitic (1), and peritoneal dialysis fluid (8). Specifically, inoculation of BACTEC blood culture bottles with sterile fluids has proven effective for the recovery of a variety of microorganisms (4, 5), including fungi (9).

In both of the reported cases, PD fluid submitted for culture signaled positive by the BACTEC 9240 system within several days, though microscopy with Gram's stain was negative. Subsequently, in both cases visual inspection was needed to identify the growth of filamentous fungi within the blood culture bottles.

The two reports indicate that fluid was initially recovered from positive blood culture bottles via needle extraction. The current BACTEC blood culture bottle is approximately 14 mm in diameter at the top and 17 mm at the base of the neck. The length of the neck is approximately 50 mm, which exceeds the length of many standard needles. These dimensions are designed to accommodate the plastic safety sheath that is used with the Vacutainer (Becton Dickinson) needle system. The aim of this system is to reduce the risk of needlestick injuries.

It is likely that due to the filamentous nature of these fungi (Curvularia inaequalis [6] and Cunninghamella bertholletiae [7]), the clumps of mycelium did not rapidly travel down into the neck of the bottle when inverted. As such, it is also likely that the reach of the needle was exceeded and no hyphae were drawn out, yielding negative microscopy results. It has been previously demonstrated experimentally that filamentous fungi that form visible mycelial masses in blood culture bottles may still fail to release spores or hyphae into the broth (2). In cases such as these, uncapping the bottle and manually extracting pieces of the fungal mass may be necessary.

The visual inspection of blood culture bottles in order to avoid false-negative results is not a recent concept (3). Moreover, the importance of this practice should not be overlooked, for a delay in identification of fungal isolates may result in the delay of appropriate antifungal treatment. So, it bears repeating that, as a rule, when a blood culture bottle with a positive signal is found to have a negative microscopic examination, a visual inspection must be performed, or a vital piece of information may be missed or even discarded.

FOOTNOTES

  • Ed. Note: J.D.P. is an author of reference 6.

  • Copyright © 2006 American Society for Microbiology

REFERENCES

  1. 1.↵
    Bobadilla, M., J. Sifuentes, and G. Garcia-Tsao. 1989. Improved method for bacteriological diagnosis of spontaneous bacterial peritonitis. J. Clin. Microbiol.27:2145-2147.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    Breathnach, A., and J. Evans. 1995. Growth and detection of filamentous fungi in the BacT/Alert blood culture system. J. Clin. Pathol.48:670-672.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    Fischer, G. W., R. Longfield, V. G. Hemming, A. Valdes-Dapena, and L. P. Smith. 1982. Pneumococcal sepsis with false-negative blood cultures. Am. J. Clin. Pathol.78:348-350.
    OpenUrlPubMedWeb of Science
  4. 4.↵
    Fuller, D. D., and T. E. Davis. 1997. Comparison of BACTEC plus Aerobic/F, Anaerobic/F, Peds Plus/F, and Lytic/F media with and without fastidious organism supplement to conventional methods for culture of sterile body fluids. Diagn. Microbiol. Infect. Dis.29:219-225.
    OpenUrlCrossRefPubMed
  5. 5.↵
    Hughes, J. G., E. A. Vetter, R. Patel, C. D. Schleck, S. Harmsen, L. T. Turgeant, and F. R. Cockerill III. 2001. Culture with BACTEC Peds Plus/F bottle compared with conventional methods for detection of bacteria in synovial fluid. J. Clin. Microbiol.39:4468-4471.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    Pimentel, J. D., K. Mahadevan, A. Woodgyer, L. Sigler, C. Gibas, O. C. Harris, M. Lupino, and E. Athan. 2005. Peritonitis due to Curvularia inaequalis in an elderly patient undergoing peritoneal dialysis and a review of six cases of peritonitis associated with other Curvularia spp. J. Clin. Microbiol.43:4288-4292.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    Pimentel, J. D., G. Dreyer, and G. D. Lum. 2006. Peritonitis due to Cunninghamella bertholletiae in a patient undergoing continuous ambulatory peritoneal dialysis. J. Med. Microbiol.55:115-118.
    OpenUrlCrossRefPubMedWeb of Science
  8. 8.↵
    Rayner, B. L., D. S. Williams, and S. Oliver. 1993. Inoculation of peritoneal dialysate fluid into blood culture bottles improves culture rates. S. Afr. Med. J.83:42-43.
    OpenUrlPubMed
  9. 9.↵
    Thuret, G., A. Carricajo, A. C. Vautrin, H. Raberin, S. Acquart, O. Garraud, P. Gain, and G. Aubert. 2005. Efficiency of blood culture bottles for the fungal sterility testing of corneal organ culture media. Br. J. Ophthalmol.89:586-590.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    von Essen, R., and A. Holtta. 1986. Improved method of isolating bacteria from joint fluids by the use of blood culture bottles. Ann. Rheum. Dis.45:454-457.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top
Download PDF
Citation Tools
False-Negative Culture Results with Fungal Isolates from Peritoneal Dialysis Fluid
Jason D. Pimentel, Gary D. Lum
Journal of Clinical Microbiology Mar 2006, 44 (3) 1206; DOI: 10.1128/JCM.44.3.1206.2006

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Print

Alerts
Sign In to Email Alerts with your Email Address
Email

Thank you for sharing this Journal of Clinical Microbiology article.

NOTE: We request your email address only to inform the recipient that it was you who recommended this article, and that it is not junk mail. We do not retain these email addresses.

Enter multiple addresses on separate lines or separate them with commas.
False-Negative Culture Results with Fungal Isolates from Peritoneal Dialysis Fluid
(Your Name) has forwarded a page to you from Journal of Clinical Microbiology
(Your Name) thought you would be interested in this article in Journal of Clinical Microbiology.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
False-Negative Culture Results with Fungal Isolates from Peritoneal Dialysis Fluid
Jason D. Pimentel, Gary D. Lum
Journal of Clinical Microbiology Mar 2006, 44 (3) 1206; DOI: 10.1128/JCM.44.3.1206.2006
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Top
  • Article
    • FOOTNOTES
    • REFERENCES
  • Info & Metrics
  • PDF

KEYWORDS

fungi
mycoses
Peritoneal Dialysis, Continuous Ambulatory
Peritonitis

Related Articles

Cited By...

About

  • About JCM
  • Editor in Chief
  • Board of Editors
  • Editor Conflicts of Interest
  • For Reviewers
  • For the Media
  • For Librarians
  • For Advertisers
  • Alerts
  • RSS
  • FAQ
  • Permissions
  • Journal Announcements

Authors

  • ASM Author Center
  • Submit a Manuscript
  • Article Types
  • Resources for Clinical Microbiologists
  • Ethics
  • Contact Us

Follow #JClinMicro

@ASMicrobiology

       

ASM Journals

ASM journals are the most prominent publications in the field, delivering up-to-date and authoritative coverage of both basic and clinical microbiology.

About ASM | Contact Us | Press Room

 

ASM is a member of

Scientific Society Publisher Alliance

 

American Society for Microbiology
1752 N St. NW
Washington, DC 20036
Phone: (202) 737-3600

 

Copyright © 2021 American Society for Microbiology | Privacy Policy | Website feedback

Print ISSN: 0095-1137; Online ISSN: 1098-660X