Skip to main content
  • ASM
    • Antimicrobial Agents and Chemotherapy
    • Applied and Environmental Microbiology
    • Clinical Microbiology Reviews
    • Clinical and Vaccine Immunology
    • EcoSal Plus
    • Eukaryotic Cell
    • Infection and Immunity
    • Journal of Bacteriology
    • Journal of Clinical Microbiology
    • Journal of Microbiology & Biology Education
    • Journal of Virology
    • mBio
    • Microbiology and Molecular Biology Reviews
    • Microbiology Resource Announcements
    • Microbiology Spectrum
    • Molecular and Cellular Biology
    • mSphere
    • mSystems
  • Log in
  • My alerts
  • My Cart

Main menu

  • Home
  • Articles
    • Current Issue
    • Accepted Manuscripts
    • COVID-19 Special Collection
    • Archive
    • Minireviews
  • For Authors
    • Submit a Manuscript
    • Scope
    • Editorial Policy
    • Submission, Review, & Publication Processes
    • Organization and Format
    • Errata, Author Corrections, Retractions
    • Illustrations and Tables
    • Nomenclature
    • Abbreviations and Conventions
    • Publication Fees
    • Ethics Resources and Policies
  • About the Journal
    • About JCM
    • Editor in Chief
    • Editorial Board
    • For Reviewers
    • For the Media
    • For Librarians
    • For Advertisers
    • Alerts
    • RSS
    • FAQ
  • Subscribe
    • Members
    • Institutions
  • ASM
    • Antimicrobial Agents and Chemotherapy
    • Applied and Environmental Microbiology
    • Clinical Microbiology Reviews
    • Clinical and Vaccine Immunology
    • EcoSal Plus
    • Eukaryotic Cell
    • Infection and Immunity
    • Journal of Bacteriology
    • Journal of Clinical Microbiology
    • Journal of Microbiology & Biology Education
    • Journal of Virology
    • mBio
    • Microbiology and Molecular Biology Reviews
    • Microbiology Resource Announcements
    • Microbiology Spectrum
    • Molecular and Cellular Biology
    • mSphere
    • mSystems

User menu

  • Log in
  • My alerts
  • My Cart

Search

  • Advanced search
Journal of Clinical Microbiology
publisher-logosite-logo

Advanced Search

  • Home
  • Articles
    • Current Issue
    • Accepted Manuscripts
    • COVID-19 Special Collection
    • Archive
    • Minireviews
  • For Authors
    • Submit a Manuscript
    • Scope
    • Editorial Policy
    • Submission, Review, & Publication Processes
    • Organization and Format
    • Errata, Author Corrections, Retractions
    • Illustrations and Tables
    • Nomenclature
    • Abbreviations and Conventions
    • Publication Fees
    • Ethics Resources and Policies
  • About the Journal
    • About JCM
    • Editor in Chief
    • Editorial Board
    • For Reviewers
    • For the Media
    • For Librarians
    • For Advertisers
    • Alerts
    • RSS
    • FAQ
  • Subscribe
    • Members
    • Institutions
Bacteriology

Discarding the Initial Aliquot of Blood Does Not Reduce Contamination Rates in Intravenous-Catheter-Drawn Blood Cultures

Sukrut Dwivedi, Rohit Bhalla, Donald R. Hoover, Melvin P. Weinstein
Sukrut Dwivedi
1Division of Infectious Diseases, Allergy & Immunology, Departments of Medicine
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rohit Bhalla
1Division of Infectious Diseases, Allergy & Immunology, Departments of Medicine
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Donald R. Hoover
1Division of Infectious Diseases, Allergy & Immunology, Departments of Medicine
3Department of Statistics and Biostatistics, Rutgers University, New Brunswick, New Jersey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Melvin P. Weinstein
1Division of Infectious Diseases, Allergy & Immunology, Departments of Medicine
2Pathology, UMDNJ-Robert Wood Johnson Medical School, New Brunswick, New Jersey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: weinstei@umdnj.edu
DOI: 10.1128/JCM.00292-09
  • Article
  • Info & Metrics
  • PDF
Loading

ABSTRACT

Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial 5 to 10 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures for adults. Thirty milliliters of blood was obtained aseptically. The first 10 ml, rather than being discarded, was inoculated into an aerobic culture vial. Using a second sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance (true versus contaminant). Out of 653 IVC-drawn blood culture pairs, both vials were contaminated in 38 pairs (5.8%); only the “discard” vial was contaminated in 33 (5.1%); and only the “standard” vial was contaminated in 31 (4.7%). Overall CR were 10.9% for the discard vial versus 10.5% for the standard vial (P = 0.90). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR.

The standard method for obtaining blood for culture is venipuncture using aseptic techniques. With greater utilization of intravenous access catheters (e.g., PICC, Hickman, etc.), blood cultures often are obtained from these devices, yet there is no standardized method for obtaining blood for culture by this technique. Several reports have demonstrated increased blood culture contamination rates (i.e., false-positive results) when blood cultures are obtained from catheters (4, 8, 10, 15), which, in turn, can lead to inappropriate antibiotic administration as well as additional unnecessary diagnostic testing. Some authorities recommend discarding the first 5 to 10 ml of blood when obtaining blood from intravenous catheters (IVCs) prior to inoculating the blood culture vials (17), whereas others do not (1, 9, 16). The purpose of discarding these aliquots of blood is to remove any substances that could potentially inhibit microbial growth (e.g., heparin) (6, 19) and to reduce blood culture contamination rates. However, there are few published systematic assessments of this issue, no consensus recommendations on how to draw blood cultures from an IVC, and no controlled comparative evaluations of different techniques to obtain blood culture samples from an IVC.

It has been standard practice at our institution to discard the first 10 ml of blood prior to obtaining blood for culture from IVCs. If patients have repeated blood cultures, in which 10 ml of blood is discarded with each culture, nosocomial anemia may occur or worsen and result in added morbidity (1, 3, 11, 18, 21). To determine whether discarding the initial aliquot of blood from IVC-drawn blood cultures reduces contamination, we inoculated the initial 10-ml sample of blood that would have been discarded into an aerobic blood culture vial and compared contamination rates in these vials with contamination rates in the “standard” blood sample obtained for culture from the same patient.

MATERIALS AND METHODS

Adult inpatients (≥18 years old) in three oncology nursing units for whom the attending physician ordered a catheter-drawn blood culture from 29 March to 9 October 2007 at Robert Wood Johnson University Hospital, New Brunswick, NJ, were included. The study was approved by the Robert Wood Johnson Medical School Institutional Review Board.

For this study, a “set” was defined as three culture bottles, two aerobic and one anaerobic, obtained from an indwelling catheter. The catheter hub was initially cleansed with 70% isopropyl alcohol and then allowed to dry. The hub was then disinfected with 2% iodine tincture and allowed to dry for 30 s. Using a sterile syringe, the IVC was flushed with 10 ml of normal saline solution. Using a sterile syringe, 10 ml of blood, the “discard” aliquot, was drawn from the IVC and inoculated into a Bactec Plus aerobic/F culture vial. The IVC hub was then recleansed with isopropyl alcohol and iodine tincture in the same fashion. Using a sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots into a Bactec Plus aerobic/F vial, the “standard” vial, and a Bactec Plus anaerobic/F vial.

Positive blood culture sets were analyzed to determine whether the isolates represented true infection or contamination, and contamination rates in the discard vial were compared to those in the standard aerobic vial. Factors used to differentiate contaminants from clinically important pathogens included the identity of the organism, the number of positive blood culture sets versus the number of culture sets obtained, and when appropriate, review of the medical record of the patient with the positive culture to compare the results to those of any peripheral blood cultures obtained during the same time frame (20). Data were entered and saved on Excel spreadsheets. Overall proportions of contamination in the discard and standard vials were then compared using McNemar's discordant pairs test of matched results for the same subject.

RESULTS

During the study period, there were a total of 653 blood culture sets collected from IVCs with matched discard and standard vial pairs. In 33 instances (5.1%), only the discard vial was contaminated, and in 31 instances (4.7%), only the standard vial was contaminated. In 38 instances, both the standard and discard vials were contaminated (5.8%). Thus, overall contamination rates for the discard and standard vials were 10.9% and 10.5%, respectively (P = 0.90; 95% confidence interval for difference in contamination rates from the normal approximation of the multinomial, −1.9% to +2.7%). In 551 instances (84.4%), neither the standard vial nor the discard vial was contaminated. In four instances, only the discard bottle grew a true pathogen, and in six instances, only the standard bottle grew a true pathogen. In each of these cases, other blood cultures taken in the same time frame or previously also grew the same pathogen.

DISCUSSION

IVCs frequently are used to administer chemotherapy, blood products, total parenteral nutrition, antibiotics, and many other medications. In addition to the administration of therapeutic agents, IVCs also are used to obtain blood samples to reduce the trauma associated with venipuncture. Although the preferred method for obtaining blood cultures is peripheral venipuncture (2, 7), blood for culture is increasingly obtained from IVCs.

Several methods for obtaining blood for culture via IVCs have been described. In the “discard” method, blood is aspirated into a syringe to clear the catheter of any residual intravenous solutions and medications, and it is then discarded. A second sterile syringe is then used to obtain blood for culture. Blood immediately beyond the hub of an IVC is thought to be diluted by the IV or flush solution. The blood that is removed allows the vein to refill from the capillary bed, thereby allowing the lumen of the catheter to fill with blood more representative of the total venous circulation (14). In some cases, the discard aliquot is described as removal of the first aspirate without flushing the catheter. In others, the discard aliquot is described as including an initial flush of the device and then withdrawal of a discard specimen. In our institution, the discard technique involved an initial flush.

The discard method is used commonly. Seventy-five percent of pediatric bone marrow transplant units reported using this method (12). According to the Oncology Nursing Society's access device guidelines (5), the discard method is most commonly used in adults as well. An informal online survey recently confirmed that institutions using this method usually discard 5 to 10 ml of blood before inoculating culture bottles (E. J. Baron, personal communication).

MacGeorte et al. (13) reported that adult bone marrow transplant patients lost an average of 95.7 ml of blood per week not including the blood volume for diagnostic testing, assuming that 6 ml of blood were discarded for each lab draw. In severely ill, febrile patients, blood cultures are done frequently, and discarding of 5 to 10 ml of blood at the time of each culture can result in significant blood loss and potential iatrogenic anemia, which, in turn, can lead to transfusion-associated risks.

Although Everts and Harding (9) reported no significant difference in contamination rates between first and second drawn samples (17.1% versus 15.8%), only 152 blood cultures were evaluated. Our study, which has a substantially larger sample size, confirms the observation that discarding the initial aliquot of blood from an IVC-drawn blood culture does not reduce contamination rates. Despite recommendations to use peripheral venipuncture as the preferred method of obtaining blood for culture, sometimes for ease or for other reasons, blood is drawn through an IVC. Whereas we do not advocate IVC-drawn blood cultures, we recognize the reality that some will be obtained in this fashion. Since discarding the initial aliquot of blood may contribute to nosocomial anemia and does not reduce contamination rates, we believe this practice should be abandoned.

FOOTNOTES

    • Received 9 February 2009.
    • Returned for modification 28 March 2009.
    • Accepted 21 July 2009.
  • Copyright © 2009 American Society for Microbiology

REFERENCES

  1. 1.↵
    Baron, E. J. 2006. Blood cultures do not require discarding of first few ml of blood. ClinMicroNotes21:2006.
    OpenUrl
  2. 2.↵
    Baron, E. J., M. P. Weinstein, W. M. Dunne, Jr., P. Yagupsky, D. F. Welch, and D. M. Wilson. 2005. Cumitech 1C, Blood cultures IV. Coordinating ed., E. J. Baron. ASM Press, Washington, DC.
  3. 3.↵
    Barton, S., T. Chase, B. Latham, and M. K. Ravens. 2004. Comparing two methods to obtain blood specimens from pediatric central venous catheters. J. Pediatr. Oncol. Nurs.21:320-326.
    OpenUrlCrossRefPubMed
  4. 4.↵
    Bryant, J. K., and C. L. Strand. 1987. Reliability of blood cultures collected from intravascular catheter versus venipuncture. Am. J. Clin. Pathol.88:113-116.
    OpenUrlPubMedWeb of Science
  5. 5.↵
    Camp-Sorrell, D. (ed.). 2004. Access device guidelines: recommendations for nursing practice and education, 2nd ed. Oncology Nursing Society, Pittsburgh, PA.
  6. 6.↵
    Christman, J. F., and D. G. Doherty. 1956. The antimicrobial action of heparin. J. Bacteriol.72:433-435.
    OpenUrlFREE Full Text
  7. 7.↵
    CLSI. 2007. Principles and procedures for blood cultures; approved guideline. CLSI document M47-A. Clinical and Laboratory Standards Institute, Wayne, PA.
  8. 8.↵
    DesJardin, J. A., M. A. Falagas, R. Ruthazer, J. Griffith, D. Wawrose, D. Schenkein, K. Miller, and D. R. Snydman. 1999. Clinical utility of blood cultures drawn from indwelling central venous catheters in hospitalized patients with cancer. Ann. Intern. Med.131:641-647.
    OpenUrlPubMedWeb of Science
  9. 9.↵
    Everts, R. J., and H. Harding. 2004. Catheter drawn blood cultures: is withdrawing the heparin lock beneficial? Pathology36:170-173.
    OpenUrlCrossRefPubMed
  10. 10.↵
    Everts, R. J., E. N. Vinson, P. O. Adholla, and L. B. Reller. 2001. Contamination of catheter-drawn blood cultures. J. Clin. Microbiol.39:3393-3394.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    Holmes, K. R. 1998. Comparison of push-pull versus discard method from central venous catheters for blood testing. J. Intraven. Nurs.21:282-285.
    OpenUrlPubMed
  12. 12.↵
    Keller, C. A. 1994. Methods of drawing blood samples through central venous catheters in pediatric patients undergoing bone marrow transplant: results of a national survey. Oncol. Nurs. Forum21:879-884.
    OpenUrlPubMed
  13. 13.↵
    MacGeorte, L., L. Steeves, and R. H. Steeves. 1988. Comparison of the mixing and reinfusion methods of drawing blood from a Hickman catheter. Oncol. Nurs. Forum15:335-338.
    OpenUrlPubMed
  14. 14.↵
    Mohler, M., Y. Sato, K. Bobick, and L. C. Wise. 1998. The reliability of blood sampling from peripheral intravenous infusion lines. J. Intraven. Nurs.21:209-214.
    OpenUrlPubMed
  15. 15.↵
    Norberg, A., N. C. Christopher, M. L. Ramundo, J. R. Bower, and S. A. Berman. 2003. Contamination rates of blood cultures obtained by dedicate phlebotomy versus intravenous catheter. JAMA289:726-729.
    OpenUrlCrossRefPubMedWeb of Science
  16. 16.↵
    Penwarden, L. M., and P. G. Montgomery. 2002. Developing a protocol for obtaining blood cultures from a central venous catheters and peripheral sites. Clin. J. Oncol. Nurs.6:268-270.
    OpenUrlCrossRefPubMed
  17. 17.↵
    Ruge, D. G., R. L. Sandin, S. A. Siegelski, J. N. Greene, and N. Johnson. 2002. Reduction in blood culture contamination rates establishment of policy for central intravenous catheters. Lab. Med.33:797-800.
    OpenUrlCrossRef
  18. 18.↵
    Thavendiranathan, P., A. Bagai, A. Ebidia, A. S. Detsky, and N. K. Choudhry. 2005. Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels. J. Gen. Intern. Med.20:520-524.
    OpenUrlCrossRefPubMedWeb of Science
  19. 19.↵
    Warren, G. F., Jr. 1950. The effect of heparin on the growth of bacteria and yeast. J. Bacteriol.60:171-174.
    OpenUrlFREE Full Text
  20. 20.↵
    Weinstein, M. P., M. L. Towns, S. M. Quartey, S. Mirrett, L. G. Reimer, G. Parmigiani, and L. B. Reller. 1997. The clinical significance of positive blood cultures in the 1990s: a prospective comprehensive evaluation of the microbiology, epidemiology, and outcome of bacteremia and fungemia in adults. Clin. Infect. Dis.24:584-602.
    OpenUrlCrossRefPubMedWeb of Science
  21. 21.↵
    Wisser, D., K. Van Ackern, E. Knoll, H. Wisser, and T. Bertsch. 2003. Blood loss from laboratory tests. Clin. Chem.49:1651-1655.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top
Download PDF
Citation Tools
Discarding the Initial Aliquot of Blood Does Not Reduce Contamination Rates in Intravenous-Catheter-Drawn Blood Cultures
Sukrut Dwivedi, Rohit Bhalla, Donald R. Hoover, Melvin P. Weinstein
Journal of Clinical Microbiology Aug 2009, 47 (9) 2950-2951; DOI: 10.1128/JCM.00292-09

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Print

Alerts
Sign In to Email Alerts with your Email Address
Email

Thank you for sharing this Journal of Clinical Microbiology article.

NOTE: We request your email address only to inform the recipient that it was you who recommended this article, and that it is not junk mail. We do not retain these email addresses.

Enter multiple addresses on separate lines or separate them with commas.
Discarding the Initial Aliquot of Blood Does Not Reduce Contamination Rates in Intravenous-Catheter-Drawn Blood Cultures
(Your Name) has forwarded a page to you from Journal of Clinical Microbiology
(Your Name) thought you would be interested in this article in Journal of Clinical Microbiology.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Discarding the Initial Aliquot of Blood Does Not Reduce Contamination Rates in Intravenous-Catheter-Drawn Blood Cultures
Sukrut Dwivedi, Rohit Bhalla, Donald R. Hoover, Melvin P. Weinstein
Journal of Clinical Microbiology Aug 2009, 47 (9) 2950-2951; DOI: 10.1128/JCM.00292-09
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Top
  • Article
    • ABSTRACT
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • FOOTNOTES
    • REFERENCES
  • Info & Metrics
  • PDF

KEYWORDS

bacteremia
blood
Blood Specimen Collection
Diagnostic Errors

Related Articles

Cited By...

About

  • About JCM
  • Editor in Chief
  • Board of Editors
  • Editor Conflicts of Interest
  • For Reviewers
  • For the Media
  • For Librarians
  • For Advertisers
  • Alerts
  • RSS
  • FAQ
  • Permissions
  • Journal Announcements

Authors

  • ASM Author Center
  • Submit a Manuscript
  • Article Types
  • Resources for Clinical Microbiologists
  • Ethics
  • Contact Us

Follow #JClinMicro

@ASMicrobiology

       

ASM Journals

ASM journals are the most prominent publications in the field, delivering up-to-date and authoritative coverage of both basic and clinical microbiology.

About ASM | Contact Us | Press Room

 

ASM is a member of

Scientific Society Publisher Alliance

 

American Society for Microbiology
1752 N St. NW
Washington, DC 20036
Phone: (202) 737-3600

 

Copyright © 2021 American Society for Microbiology | Privacy Policy | Website feedback

Print ISSN: 0095-1137; Online ISSN: 1098-660X